Rapid kVp-switching DECT portal venous phase abdominal CT scans in patients with large body habitus: image quality considerations
- 30 January 2020
- journal article
- research article
- Published by Springer Nature in Abdominal Radiology
- Vol. 45 (9) , 2902-2909
Abstract
Purpose To assess the diagnostic image quality and material decomposition characteristics of portal venous phase abdominal CT scans performed on rapid kVp-switching DECT (rsDECT) in patients with large body habitus. Methods We retrospectively included consecutive patients with large body habitus (≥ 90 kg) undergoing portal venous phase abdominal CT scans on rsDECT scanners between Sep 2014 and March 2018. Qualitative and quantitative assessment of the DECT data sets [65 keV monoenergetic, material density iodine (MD-I) and material density water (MD-W) images] was performed for determination of image quality (IQ) and image noise. Correlation of qualitative assessment scores with weight, BMI and patients’ diameter were calculated using Pearson correlation test. Optimal thresholds were calculated using AUC and Youden index to define most appropriate size cut off, below which the IQ of material density images is largely acceptable. Results The 65 keV monoenergetic images were of diagnostic quality (diagnostic acceptability, DA ≥ 3) in 97.8% of patients (n = 91/93). However, there was significant IQ degradation of MD-I images in 20.4% (n = 19/93, DA < 3) of patients. Similarly, there was significant degradation (DA < 3) of MD-W images in 26.9% (25/92). Clinically significant artifacts (PA ≥ 3/4) were seen in 31% (n = 29/93) and 32.3% (30/93) of MD-I and MD-W images respectively. Optimal threshold for diagnostic acceptability of MD-I images were 110 kg for weight and 33.5 kg/m2 for BMI. Conclusion Rapid kVp-switching DECT provides diagnostically acceptable monoenergetic images for patients with large body habitus (≥ 90 kg). There is degradation of IQ in the material density specific images particularly in patients weighing > 110 kg and with BMI > 33.5 kg/m2, due to higher number of artifacts.Keywords
This publication has 32 references indexed in Scilit:
- Impact of Body Habitus on Radiologic InterpretationsAcademic Radiology, 2014
- Performance of Iterative Reconstruction and Automated Tube Voltage Selection on the Image Quality and Radiation Dose in Abdominal CT ScansJournal of Computer Assisted Tomography, 2013
- Comparative assessment of three image reconstruction techniques for image quality and radiation dose in patients undergoing abdominopelvic multidetector CT examinationsBritish Journal of Radiology, 2013
- Best Practice: Implementation and Use of Abdominal Dual-Energy CT in Routine Patient CareAmerican Journal of Roentgenology, 2012
- Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adultsEuropean Radiology, 2012
- Low-Tube-Voltage, High-Tube-Current Multidetector Abdominal CT: Improved Image Quality and Decreased Radiation Dose with Adaptive Statistical Iterative Reconstruction Algorithm—Initial Clinical ExperienceRadiology, 2010
- Innovations in CT Dose Reduction Strategy: Application of the Adaptive Statistical Iterative Reconstruction AlgorithmAmerican Journal of Roentgenology, 2010
- Principles of CT: Radiation Dose and Image QualityJournal of Nuclear Medicine Technology, 2007
- Impact of Obesity on RadiologyRadiologic Clinics of North America, 2007
- Abdominal diameters as indicators of visceral fat: comparison between magnetic resonance imaging and anthropometryBritish Journal of Nutrition, 1993