Design and Integration of Electrical Bio-impedance Sensing in Surgical Robotic Tools for Tissue Identification and Display
Open Access
- 17 July 2019
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Robotics and AI
- Vol. 6
Abstract
The integration of intra-operative sensors into surgical robots is a hot research topic since this can significantly facilitate complex surgical procedures by enhancing surgical awareness with real-time tissue information. However, currently available intra-operative sensing technologies are mainly based on image processing and force feedback, which normally require heavy computation or complicated hardware modifications of existing surgical tools. This paper presents the design and integration of electrical bio-impedance sensing into a commercial surgical robot tool, leading to the creation of a novel smart instrument that allows the identification of tissues by simply touching them. In addition, an advanced user interface is designed to provide guidance during the use of the system and to allow augmented-reality visualization of the tissue identification results. The proposed system imposes minor hardware modifications to an existing surgical tool, but adds the capability to provide a wealth of data about the tissue being manipulated. This has great potential to allow the surgeon (or an autonomous robotic system) to better understand the surgical environment. To evaluate the system, a series of ex-vivo experiments were conducted. The experimental results demonstrate that the proposed sensing system can successfully identify different tissue types with 100% classification accuracy. In addition, the user interface was shown to effectively and intuitively guide the user to measure the electrical impedance of the target tissue, presenting the identification results as augmented-reality markers for simple and immediate recognition.Keywords
This publication has 21 references indexed in Scilit:
- Understanding Cognitive Performance During Robot-Assisted SurgeryUrology, 2015
- Detection of intraneural needle-placement with multiple frequency bioimpedance monitoring: a novel methodJournal of Clinical Monitoring and Computing, 2015
- Implementation of Tactile Sensing for Palpation in Robot-Assisted Minimally Invasive Surgery: A ReviewIEEE Sensors Journal, 2014
- Review of surgical robotics user interface: what is the best way to control robotic surgery?Surgical Endoscopy, 2012
- Electrical impedance characterization of normal and cancerous human hepatic tissuePhysiological Measurement, 2010
- Impedance-based tissue discrimination for needle guidancePhysiological Measurement, 2009
- Ergonomics in minimally invasive surgeryInternational Journal Of Clinical Practice, 2007
- Toward image-guided robotic surgery: determining intrinsic accuracy of the da Vinci robotInternational Journal of Computer Assisted Radiology and Surgery, 2006
- Optimal Hand-Eye Calibration2006
- In vitro tissue characterization and modelling using electrical impedance measurements in the 100 Hz-10 MHz frequency rangePhysiological Measurement, 1995