Comparison of Repetitive Cardiac Output Measurements at Rest and End-Exercise by Direct Fick Using Pulse Oximetry vs. Blood Gases in Patients With Pulmonary Hypertension
Authors:
Open Access
- 23 November 2021
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 8
Abstract
Background: Exact and simultaneous measurements of mean pulmonary artery pressure (mPAP) and cardiac output (CO) are crucial to calculate pulmonary vascular resistance (PVR), which is essential to define pulmonary hypertension (PH). Simultaneous measurements of mPAP and CO are not feasible using the direct Fick (DF) method, due to the necessity to sample blood from the catheter-tip. We evaluated a modified DF method, which allows simultaneous measurement of mPAP and CO without needing repetitive blood samples.Methods: Twenty-four patients with pulmonary arterial or chronic thromboembolic PH had repetitive measurements of CO at rest and end-exercise during three phases of a crossover trial. CO was assessed by the original DF method using oxygen uptake, measured by a metabolic unit, and arterial and mixed venous oxygen saturations from co-oximetry of respective blood gases served as reference. These CO measurements were then compared with a modified DF method using pulse oximetry at the catheter- and fingertip.Results: The bias among CO measurements by the two DF methods at rest was −0.26 L/min with limits of agreement of ±1.66 L/min. The percentage error was 28.6%. At the end-exercise, the bias between methods was 0.29 L/min with limits of agreement of ±1.54 L/min and percentage error of 16.1%.Conclusion: Direct Fick using a catheter- and fingertip pulse oximetry (DFp) is a practicable and reliable method for assessing CO in patients with PH. This method has the advantage of allowing simultaneous measurement of PAP and CO, and frequent repetitive measurements are needed during exercise.Clinical Trial Registration:https://clinicaltrials.gov/ct2/show/NCT02755259, identifier: NCT02755259.Keywords
Funding Information
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (32003B_146246/1)
This publication has 47 references indexed in Scilit:
- The German adaptation of the Cambridge pulmonary hypertension outcome review (CAMPHOR)Health and Quality of Life Outcomes, 2012
- Pulse contour cardiac output derived from non‐invasive arterial pressure in cardiovascular diseaseAnaesthesia, 2010
- Cardiac Output Monitoring Using Indicator-Dilution Techniques: Basics, Limits, and PerspectivesAnesthesia & Analgesia, 2010
- Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies – with specific reference to the measurement of cardiac outputCritical Care, 2009
- Design, Analysis, and Interpretation of Method-Comparison StudiesAACN Advanced Critical Care, 2008
- Measurement of quality of life in pulmonary hypertension and its significanceEuropean Respiratory Journal, 2006
- Assumed oxygen consumption frequently results in large errors in the determination of cardiac outputThe Journal of Thoracic and Cardiovascular Surgery, 2005
- Analysis of factors affecting the variability of fick versus indicator dilution measurements of cardiac outputThe American Journal of Cardiology, 1985
- Measurement of cardiac output during exercise by the thermodilution and direct fick techniques in patients with chronic congestive heart failureThe American Journal of Cardiology, 1985