Influence of Uncertainties in Optode Positions on Self-Calibrating or Dual-Slope Diffuse Optical Measurements
Preprint
Abstract
Self-calibrating and dual-slope measurements have been used in the field of diffuse optics for robust assessment of absolute values or temporal changes in the optical properties of highly scattering media and biological tissue. These measurements employ optical probes with a minimum of two source positions and a minimum of two detector positions. This work focuses on a quantitative analysis of the impact of errors in these source and detector positions on the assessment of optical properties. We considered linear, trapezoidal, and rectangular optode arrangements and theoretical computations based on diffusion theory for semi-infinite homogeneous media. We found that uncertainties in optodes' positions may have a greater impact on measurements of absolute scattering versus absorption coefficients. For example, 4.1% and 19% average errors in absolute absorption and scattering, respectively, can be expected by displacing every optode in a linear arrangement by 1 mm in any direction. The impact of optode position errors is typically smaller for measurements of absorption changes. For each geometrical arrangement (linear, trapezoid, rectangular), we identify the direction of the position uncertainty for each optode that has minimal impact on the optical measurements. These results can guide the optimal design of optical probes for self-calibrating and dual-slope measurements.Keywords
All Related Versions
This publication has 26 references indexed in Scilit:
- Enhancing diffuse correlation spectroscopy pulsatile cerebral blood flow signal with near-infrared spectroscopy photoplethysmographyNeurophotonics, 2023
- Open-source FlexNIRS: A low-cost, wireless and wearable cerebral health trackerNeuroImage, 2022
- Design of a source–detector array for dual-slope diffuse optical imagingReview of Scientific Instruments, 2020
- Phase dual‐slopes in frequency‐domain near‐infrared spectroscopy for enhanced sensitivity to brain tissue: First applications to human subjectsJournal of Biophotonics, 2019
- Quantitative Biomedical Optics2018
- Measuring tissue hemodynamics and oxygenation by continuous-wave functional near-infrared spectroscopy—how robust are the different calculation methods against movement artifacts?Physiological Measurement, 2014
- Development and Validation of a Cerebral Oximeter Capable of Absolute AccuracyJournal of Cardiothoracic and Vascular Anesthesia, 2012
- Impact of Extracranial Contamination on Regional Cerebral Oxygen SaturationAnesthesiology, 2012
- Reproducibility of cerebral tissue oxygen saturation measurements by near-infrared spectroscopy in newborn infantsJournal of Biomedical Optics, 2011
- Non-invasive optical monitoring of the newborn piglet brain using continuous-wave and frequency-domain spectroscopyPhysics in Medicine & Biology, 1999