Tapan Das
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tapan Das has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Angelo Sassaroli
Tufts University, Department of Biomedical Engineering, Medford, Massachusetts, United States
3 shared publications - Giles Blaney
Tufts University
3 shared publications Pranab K. Dutta
Jorhat Inst Sci & Technol, Dept Power Elect & Instrumenta Engn, Jorhat 785001, Assam, India
3 shared publicationsB.P.V. Dileep
2 shared publications- Pranab Kumar Dutta
Department of Electrical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
2 shared publications - Sergio Fantini
Tufts University
2 shared publications
Latest Publications
- Open Access
Influence of Uncertainties in Optode Positions on Self-Calibrating or Dual-Slope Diffuse Optical Measurements
Self-calibrating and dual-slope measurements have been used in the field of diffuse optics for robust assessment of absolute values or temporal changes in the optical properties of highly scattering media and biological tissue. These measurements employ optical probes with a minimum of two source positions and a minimum of two detector positions. This work focuses on a quantitative analysis of the impact of errors in these source and detector positions on the assessment of optical properties. We considered linear, trapezoidal, and rectangular optode arrangements and theoretical computations based on diffusion theory for semi-infinite homogeneous media. We found that uncertainties in optodes’ positions may have a greater impact on measurements of absolute scattering versus absorption coefficients. For example, a 4.1% and 19% average error in absolute absorption and scattering, respectively, can be expected by displacing every optode in a linear arrangement by 1 mm in any direction. The impact of optode position errors is typically smaller for measurements of absorption changes. In each geometrical arrangement (linear, trapezoid, rectangular), we identify the direction of the position uncertainty for each optode that has minimal impact on the optical measurements. These results can guide the optimal design of optical probes for self-calibrating and dual-slope measurements.
Open AccessInfluence of Uncertainties in Optode Positions on Self-Calibrating or Dual-Slope Diffuse Optical Measurements
Self-calibrating and dual-slope measurements have been used in the field of diffuse optics for robust assessment of absolute values or temporal changes in the optical properties of highly scattering media and biological tissue. These measurements employ optical probes with a minimum of two source positions and a minimum of two detector positions. This work focuses on a quantitative analysis of the impact of errors in these source and detector positions on the assessment of optical properties. We considered linear, trapezoidal, and rectangular optode arrangements and theoretical computations based on diffusion theory for semi-infinite homogeneous media. We found that uncertainties in optodes’ positions may have a greater impact on measurements of absolute scattering versus absorption coefficients. For example, a 4.1% and 19% average error in absolute absorption and scattering, respectively, can be expected by displacing every optode in a linear arrangement by 1 mm in any direction. The impact of optode position errors is typically smaller for measurements of absorption changes. In each geometrical arrangement (linear, trapezoid, rectangular), we identify the direction of the position uncertainty for each optode that has minimal impact on the optical measurements. These results can guide the optimal design of optical probes for self-calibrating and dual-slope measurements.
- Open Access
Influence of Uncertainties in Optode Positions on Self-Calibrating or Dual-Slope Diffuse Optical Measurements
Self-calibrating and dual-slope measurements have been used in the field of diffuse optics for robust assessment of absolute values or temporal changes in the optical properties of highly scattering media and biological tissue. These measurements employ optical probes with a minimum of two source positions and a minimum of two detector positions. This work focuses on a quantitative analysis of the impact of errors in these source and detector positions on the assessment of optical properties. We considered linear, trapezoidal, and rectangular optode arrangements and theoretical computations based on diffusion theory for semi-infinite homogeneous media. We found that uncertainties in optodes' positions may have a greater impact on measurements of absolute scattering versus absorption coefficients. For example, 4.1% and 19% average errors in absolute absorption and scattering, respectively, can be expected by displacing every optode in a linear arrangement by 1 mm in any direction. The impact of optode position errors is typically smaller for measurements of absorption changes. For each geometrical arrangement (linear, trapezoid, rectangular), we identify the direction of the position uncertainty for each optode that has minimal impact on the optical measurements. These results can guide the optimal design of optical probes for self-calibrating and dual-slope measurements.
Open AccessInfluence of Uncertainties in Optode Positions on Self-Calibrating or Dual-Slope Diffuse Optical Measurements
Self-calibrating and dual-slope measurements have been used in the field of diffuse optics for robust assessment of absolute values or temporal changes in the optical properties of highly scattering media and biological tissue. These measurements employ optical probes with a minimum of two source positions and a minimum of two detector positions. This work focuses on a quantitative analysis of the impact of errors in these source and detector positions on the assessment of optical properties. We considered linear, trapezoidal, and rectangular optode arrangements and theoretical computations based on diffusion theory for semi-infinite homogeneous media. We found that uncertainties in optodes' positions may have a greater impact on measurements of absolute scattering versus absorption coefficients. For example, 4.1% and 19% average errors in absolute absorption and scattering, respectively, can be expected by displacing every optode in a linear arrangement by 1 mm in any direction. The impact of optode position errors is typically smaller for measurements of absorption changes. For each geometrical arrangement (linear, trapezoid, rectangular), we identify the direction of the position uncertainty for each optode that has minimal impact on the optical measurements. These results can guide the optimal design of optical probes for self-calibrating and dual-slope measurements.
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (23) , 29536-29544
Gaussian Distributed Semi-Analytic Reconstruction Method for Diffuse Optical Tomographic Measurement
A novel non-linear semi-analytic reconstruction method for continuous-wave diffuse optical tomography (CW-DOT) that employs a Gaussian distribution framework for tracing photon paths is presented here in this work. In highly scattering media-like tissue, photons travel on a curved photon path with cloud distribution between any light source–detector pairs. In this work, Gaussian distributed Rosenbrock’s banana function was utilized to trace the majority of photons between any source–detector pairs as curved paths with photon cloud distribution to mimic the actual photon distributions. This has led to a more realistic semi-analytic diffuse optical tomographic reconstruction technique and helped to improve the reconstruction accuracy significantly. This improved method is experimentally validated on multiple inclusion wax phantom and in vivo finger joint imaging of a healthy volunteer. Also, the proposed reconstruction method can directly estimate the tissue oxygenation level measured in terms of oxygen saturation (StO2) and oxygen capacity ( ${C}_{B}$ ) in vivo derived from hemoglobin concentrations using CW-DOT. Tissue oxygenation levels and oxygen capacities were estimated consistently and accurately. The results showed significant improvement in accuracy when compared to the generalized method where the photon paths are modeled as curved lines, estimated by different performance evaluation matrices.
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (23) , 29536-29544
Gaussian Distributed Semi-Analytic Reconstruction Method for Diffuse Optical Tomographic Measurement
A novel non-linear semi-analytic reconstruction method for continuous-wave diffuse optical tomography (CW-DOT) that employs a Gaussian distribution framework for tracing photon paths is presented here in this work. In highly scattering media-like tissue, photons travel on a curved photon path with cloud distribution between any light source–detector pairs. In this work, Gaussian distributed Rosenbrock’s banana function was utilized to trace the majority of photons between any source–detector pairs as curved paths with photon cloud distribution to mimic the actual photon distributions. This has led to a more realistic semi-analytic diffuse optical tomographic reconstruction technique and helped to improve the reconstruction accuracy significantly. This improved method is experimentally validated on multiple inclusion wax phantom and in vivo finger joint imaging of a healthy volunteer. Also, the proposed reconstruction method can directly estimate the tissue oxygenation level measured in terms of oxygen saturation (StO2) and oxygen capacity ( ${C}_{B}$ ) in vivo derived from hemoglobin concentrations using CW-DOT. Tissue oxygenation levels and oxygen capacities were estimated consistently and accurately. The results showed significant improvement in accuracy when compared to the generalized method where the photon paths are modeled as curved lines, estimated by different performance evaluation matrices.
- Open Access
- 3 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 4, 102-108
Coherent Spontaneous Hemodynamics in the Human Brain
Goal: This work investigates the presence of cerebral hemodynamics (namely Oxy (O) and Deoxy (D) hemoglobin concentrations) that are coherent with spontaneous oscillations in Arterial Blood Pressure (ABP) in 78 healthy subjects during a driving simulation task. Methods: Spatially resolved O and D were measured on the prefrontal cortex with multi-channel near-infrared spectroscopy (NIRS). Wavelet coherence and phasor analysis were performed between O and ABP, and between D and ABP to evaluate the amplitude ratio, phase difference, and duration of significant coherence. Results : In the low-frequency range, oscillations at 0.1 Hz featured significant coherence for the longest time fraction (∼10%-30%). At this frequency, the amplitude ratio and phase difference showed a greater variance across subjects than over cortical locations, and no significant difference between driving tasks and baseline. Conclusions : Measuring low-frequency cerebral hemodynamics that are coherent with systemic ABP holds promise for non-invasive assessment of cerebral perfusion and autoregulation at the cerebral microvascular level.
- 3 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 4, 102-108
Open AccessCoherent Spontaneous Hemodynamics in the Human Brain
Goal: This work investigates the presence of cerebral hemodynamics (namely Oxy (O) and Deoxy (D) hemoglobin concentrations) that are coherent with spontaneous oscillations in Arterial Blood Pressure (ABP) in 78 healthy subjects during a driving simulation task. Methods: Spatially resolved O and D were measured on the prefrontal cortex with multi-channel near-infrared spectroscopy (NIRS). Wavelet coherence and phasor analysis were performed between O and ABP, and between D and ABP to evaluate the amplitude ratio, phase difference, and duration of significant coherence. Results : In the low-frequency range, oscillations at 0.1 Hz featured significant coherence for the longest time fraction (∼10%-30%). At this frequency, the amplitude ratio and phase difference showed a greater variance across subjects than over cortical locations, and no significant difference between driving tasks and baseline. Conclusions : Measuring low-frequency cerebral hemodynamics that are coherent with systemic ABP holds promise for non-invasive assessment of cerebral perfusion and autoregulation at the cerebral microvascular level.
- Open Access
A semi-analytic reconstruction method for Diffuse Optical Tomography
The Diffuse Optical Tomography (DOT) has received considerable attention in the recent years in the field of biomedical imaging and disease detection. However, imaging through highly diffusive medium is a challenge and stability is always an issue due to the inverse problem. Here a non-linear continous wave (CW) semi-analytic reconstruction method is discussed that used curved-beam paths for tomographic imaging with no assumption on inclusion, unlike iterative methods.The non-linear Rosenbrock's function is used to approximate the paths followed by majority photons as curved ones. The modified Beer-Lambert Law (MBLL) in proposed differntial form is used to calculate the absorption coefficient of all the avilable photon paths. The computed values are back-projected along these channels and serve as the basis for image reconstruction without solving the inverse problem. For three-dimensional (3-D) imaging, measurements at three different depths covering the entire depth of the phantom are taken. These slices are stacked together followed by interpolation to form the volumetric image of the phantom to complete the tomographic imaging in its true sense. Numerical simulations, wax phantom experiments with different geometries and contrast are carried out with satisfactory results. This semi-analytic reconstruction method is simple and efficient and is suitable for real-time applications that reqiure fast absorption image reconstruction. The method is compared with the Greedy algorithms for further validation. Also, different performance evaluation matrices are estimated to assess the accuracy of the reconstructed images and the results are rather satisfactory.
Open AccessA semi-analytic reconstruction method for Diffuse Optical Tomography
The Diffuse Optical Tomography (DOT) has received considerable attention in the recent years in the field of biomedical imaging and disease detection. However, imaging through highly diffusive medium is a challenge and stability is always an issue due to the inverse problem. Here a non-linear continous wave (CW) semi-analytic reconstruction method is discussed that used curved-beam paths for tomographic imaging with no assumption on inclusion, unlike iterative methods.The non-linear Rosenbrock's function is used to approximate the paths followed by majority photons as curved ones. The modified Beer-Lambert Law (MBLL) in proposed differntial form is used to calculate the absorption coefficient of all the avilable photon paths. The computed values are back-projected along these channels and serve as the basis for image reconstruction without solving the inverse problem. For three-dimensional (3-D) imaging, measurements at three different depths covering the entire depth of the phantom are taken. These slices are stacked together followed by interpolation to form the volumetric image of the phantom to complete the tomographic imaging in its true sense. Numerical simulations, wax phantom experiments with different geometries and contrast are carried out with satisfactory results. This semi-analytic reconstruction method is simple and efficient and is suitable for real-time applications that reqiure fast absorption image reconstruction. The method is compared with the Greedy algorithms for further validation. Also, different performance evaluation matrices are estimated to assess the accuracy of the reconstructed images and the results are rather satisfactory.
- 6 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (9) , 7043-7050
Dual-Wavelength Diffuse Optical Tomographic System for Direct Concentration Measurement
This paper presents a promising dual-wavelength continuous wave (CW) diffuse optical tomography (DOT) system for direct estimation of concentrations and hemodynamic parameters for potential application in detection of rheumatoid arthritis (RA). The generalized curved-beam reconstruction technique is modified for direct estimation of hemodynamic parameters. The Rosenbrock’s function is fitted to estimate the photon path as curved one followed by majority photons that enabled the use of modified Beer-Lambert law (MBLL) in differential form with assumption that unknown absorption coefficient (la) varies from one path to another. The la values are calculated and back-projected along the photon paths for image reconstruction without solving the inverse problem. Thus, stability is not an issue in image reconstruction. Also, there is no need for baseline measurement and prior information on perturbation, unlike the iterative methods used for dynamic imaging. The reconstructed images of the distal interphalangeal (DIP) and proximal interphalangeal (PIP) joints of a healthy male volunteer showed good consistency and are used for direct optical estimation of the physiological parameters. A novel application of optical imaging beyond biomedical applications is demonstrated by imaging the gradual dispersion of viscous Indian ink and glycerin mixture in turbid water with encouraging results.
- 6 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (9) , 7043-7050
Dual-Wavelength Diffuse Optical Tomographic System for Direct Concentration Measurement
This paper presents a promising dual-wavelength continuous wave (CW) diffuse optical tomography (DOT) system for direct estimation of concentrations and hemodynamic parameters for potential application in detection of rheumatoid arthritis (RA). The generalized curved-beam reconstruction technique is modified for direct estimation of hemodynamic parameters. The Rosenbrock’s function is fitted to estimate the photon path as curved one followed by majority photons that enabled the use of modified Beer-Lambert law (MBLL) in differential form with assumption that unknown absorption coefficient (la) varies from one path to another. The la values are calculated and back-projected along the photon paths for image reconstruction without solving the inverse problem. Thus, stability is not an issue in image reconstruction. Also, there is no need for baseline measurement and prior information on perturbation, unlike the iterative methods used for dynamic imaging. The reconstructed images of the distal interphalangeal (DIP) and proximal interphalangeal (PIP) joints of a healthy male volunteer showed good consistency and are used for direct optical estimation of the physiological parameters. A novel application of optical imaging beyond biomedical applications is demonstrated by imaging the gradual dispersion of viscous Indian ink and glycerin mixture in turbid water with encouraging results.
- 6 March 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (8) , 1838-1848
Generalized curved beam back-projection method for near-infrared imaging using banana function
Near-infrared imaging (NIRI) is a sub-surface imaging that makes a trade-off in recovery accuracy with depth of penetration. On the other hand, diffuse optical tomography (DOT) images tissue up to several centimeters. However, DOT reconstruction has a stability issue due to the inverse problem. This paper proposes a generalized continuous-wave technique to image objects of dimensions 4–6 cm comparable to DOT. A nonlinear Rosenbrock’s banana function is fitted to the approximate photon path, and the fit parameter thus obtained gives the penetration depth of each channel. The calculated values of absorption change are back-projected along these curved paths for reconstruction without solving the inverse problem. This function serves as an operator for image reconstruction. Here numerical simulations, experimental validation on wax phantom with inclusions, finger joint, and degraded apple have been performed to show potential of the proposed method in imaging. Thus this computationally efficient, reliable, and simple method is suitable for practical and real-time NIRI applications.
- 6 March 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (8) , 1838-1848
Generalized curved beam back-projection method for near-infrared imaging using banana function
Near-infrared imaging (NIRI) is a sub-surface imaging that makes a trade-off in recovery accuracy with depth of penetration. On the other hand, diffuse optical tomography (DOT) images tissue up to several centimeters. However, DOT reconstruction has a stability issue due to the inverse problem. This paper proposes a generalized continuous-wave technique to image objects of dimensions 4–6 cm comparable to DOT. A nonlinear Rosenbrock’s banana function is fitted to the approximate photon path, and the fit parameter thus obtained gives the penetration depth of each channel. The calculated values of absorption change are back-projected along these curved paths for reconstruction without solving the inverse problem. This function serves as an operator for image reconstruction. Here numerical simulations, experimental validation on wax phantom with inclusions, finger joint, and degraded apple have been performed to show potential of the proposed method in imaging. Thus this computationally efficient, reliable, and simple method is suitable for practical and real-time NIRI applications.
- 1 March 2018
- Published by Elsevier in Optics Communications
- Vol. 410, 164-173
Greedy algorithms for diffuse optical tomography reconstruction
- 1 March 2018
- Published by Elsevier in Optics Communications
- Vol. 410, 164-173
Greedy algorithms for diffuse optical tomography reconstruction