Determination of percentage depth-dose curves for electron beams using different types of detectors
Authors:
- G. X. DingGDG. X. Ding
- C. W. YuCYC. W. Yu
- 9 March 2001
- journal article
- Published by Wiley in Medical Physics
- Vol. 28 (3) , 298-302
Abstract
According to the new AAPM TG-51 dosimetry protocol, reference dosimetry for electron beams is performed at depth of d(ref)=0.6R50-0.1 (cm) instead of d(max) recommended in TG-21. In clinical practice most electron beams are normalized at d(max). Therefore it becomes more important to get an accurate percentage-depth-dose (%dd) curve particularly for higher-energy electron beams in which the depth d(ref) is away from d(max). When ionization chambers are used in determining %dd curves the water-to-air stopping-power ratios and the fluence correction factors are required. The TG-51 recommends that the stopping-power ratios for realistic electron beams be used instead of the monoenergetic stopping-power ratios used in TG-21. This investigation aims to study the effects of those correction factors on the determination of %dd curves. We observed 1% deviations in the value of %dd at d(ref) for 15 and 18 MeV beams between a plane-parallel NACP and a cylindrical IC-10 chamber without considering the fluence correction factors P(fl). We explored a method to derive the fluence correction factors at any depth by using the existing fluence correction data at d(max) and tested its feasibility. We compared %dd curves measured by a diode detector and a NACP chamber with stopping-power ratios recommended by TG-51 and those recommended by TG-21. We found that for 15 and 18 MeV beams the difference in the values of %dd at d(ref) between using those two different stopping-power ratios is about 0.5%. Excellent agreement is found between %dd curves measured by the diode and by the NACP chamber when the stopping-power ratios recommended by TG-51 are used.Keywords
This publication has 11 references indexed in Scilit:
- AAPM's TG‐51 protocol for clinical reference dosimetry of high‐energy photon and electron beamsMedical Physics, 1999
- Measured overall perturbation factors at depths greater than for ionization chambers in electron beamsMedical Physics, 1999
- Measurement of Prepl Pwall factors in electron beams and in a 60Co beam for plane-parallel chambersMedical Physics, 1998
- A new approach to electron‐beam reference dosimetryMedical Physics, 1998
- Experimental determination of fluence correction factors at depths beyond dmax for a Farmer type cylindrical ionization chamber in clinical electron beamsMedical Physics, 1997
- R50 as a beam quality specifier for selecting stopping‐power ratios and reference depths for electron dosimetryMedical Physics, 1996
- The calibration and use of plane‐parallel ionization chambers for dosimetry of electron beams: An extension of the 1983 AAPM protocol report of AAPM Radiation Therapy Committee Task Group No. 39Medical Physics, 1994
- Verification of absorbed doses determined with thimble and parallel‐plate ionization chambers in clinical electron beams using ferrous sulphate dosimetryMedical Physics, 1994
- Clinical electron‐beam dosimetry: Report of AAPM Radiation Therapy Committee Task Group No. 25Medical Physics, 1991
- A protocol for the determination of absorbed dose from high‐energy photon and electron beamsMedical Physics, 1983