Electrophoresis-Assisted Active Immunoassay
- 11 November 2003
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (24) , 6813-6819
Abstract
An active assay can be defined as that in which diffusion-controlled reactions are replaced by active delivery of analytes to probe molecules. The present paper describes an electrophoresis-assisted version of an active ELISA performed in tubes or wells with a dialysis membrane attached to their bottoms. The permeability of such a membrane to small ions allows us to apply electric field perpendicular to the membrane surface and to rapidly transport and concentrate charged macromolecular analytes in its vicinity. Probe molecules were either adsorbed or covalently linked to a modified surface of a membrane from regenerated cellulose. An active assay was performed both in separate cells and in 96-well microplates. It was demonstrated that the active assay format allows one (i) to reduce assay time to minutes instead of hours, (ii) to increase sensitivity by a factor of 10−300, and (iii) to capture within 10 min up to 70% of all the analyte molecules present in 0.36 mL of solution.Keywords
This publication has 11 references indexed in Scilit:
- XPS analyses of polystyrene thin films treated under DC pulsed discharges conditions in nitrogen, oxygen and oxygen-argon mixturesThe European Physical Journal Applied Physics, 2002
- Detection of Biological Toxins on an Active Electronic MicrochipAnalytical Biochemistry, 2001
- Unbinding forces of single antibody-antigen complexes correlate with their thermal dissociation ratesProceedings of the National Academy of Sciences, 2000
- Immobilized biomolecules on plasma functionalized cellophane. I. Covalently attached α-chymotrypsinJournal of Biomaterials Science, Polymer Edition, 2000
- Extending the Range of Rate Constants Available from BIACORE: Interpreting Mass Transport-Influenced Binding DataBiophysical Journal, 1998
- Rapid determination of single base mismatch mutations in DNA hybrids by direct electric field controlProceedings of the National Academy of Sciences, 1997
- New polyacrylamide gel-based methods of sample preparation for optical microscopy: immobilization of DNA molecules for optical mappingJournal of Microscopy, 1996
- Detection and localization of individual antibody-antigen recognition events by atomic force microscopy.Proceedings of the National Academy of Sciences, 1996
- Immobilization of proteins to a carboxymethyldextran-modified gold surface for biospecific interaction analysis in surface plasmon resonance sensorsAnalytical Biochemistry, 1991
- Kinetics of antigen-antibody reactions at solid-liquid interfacesJournal of Immunological Methods, 1988