VMVictor N. Morozov

Victor N. Morozov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Victor N. Morozov has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • Tamara Ya. Morozova

    Beckman Institute for Biomedical Research, 28835 Single Oak Drive, Temecula, California 92590, and Institute of Theoretical and Experimental Biophysics, Russian Academy of Sciences, Pushchino, Moscow region, Russia 142290

    2 shared publications
  • Kenneth L. Johnson

    Biomedical Mass Spectrometry and Functional Proteomics Facility and Department of Biochemistry and Molecular Biology, Mayo Clinic and Foundation, Rochester, MN 55905, USA

    1 shared publication
  • Stephen Naylor

    Biomedical Mass Spectrometry and Functional Proteomics Facility and Department of Biochemistry and Molecular Biology, Mayo Clinic and Foundation, Rochester, MN 55905, USA

    1 shared publication

Latest Publications

  • Electrophoresis-Assisted Active Immunoassay

    by Victor N. Morozov, Tamara Ya. Morozova

    An active assay can be defined as that in which diffusion-controlled reactions are replaced by active delivery of analytes to probe molecules. The present paper describes an electrophoresis-assisted version of an active ELISA performed in tubes or wells with a dialysis membrane attached to their bottoms. The permeability of such a membrane to small ions allows us to apply electric field perpendicular to the membrane surface and to rapidly transport and concentrate charged macromolecular analytes in its vicinity. Probe molecules were either adsorbed or covalently linked to a modified surface of a membrane from regenerated cellulose. An active assay was performed both in separate cells and in 96-well microplates. It was demonstrated that the active assay format allows one (i) to reduce assay time to minutes instead of hours, (ii) to increase sensitivity by a factor of 10−300, and (iii) to capture within 10 min up to 70% of all the analyte molecules present in 0.36 mL of solution.


  • Parallel determination of multiple protein metabolite interactions using cell extract, protein microarrays and mass spectrometric detection

    by Victor N. Morozov, Tamara Ya. Morozova, Kenneth L. Johnson, Stephen Naylor

    Analysis of interactive networks between proteins and other molecular constituents is of paramount importance to delineate complex cellular processes. In order to facilitate this process, new technologies that allow rapid, high‐throughput parallel screening, as well as identification of constituents, are necessary. A particularly powerful combination in this regard could be the use of multiprotein microarrays coupled with mass spectrometry (MS). In the initial step of the method development we applied MS to single‐protein microarrays. We demonstrated that even a simplified version of the method allows rapid parallel label‐free assay of specific protein interactions with multiple metabolites derived from complex artificial and natural mixtures. The microarrays fabricated by the electrospray deposition technique and cross‐linked in glutaraldehyde vapor were brought into contact with droplets of solution containing either a natural extract of baker's yeast cells or an artificial cocktail of metabolites. After washing, the microarrays were placed into 75% methanol to denature proteins and release specifically bound metabolites. The eluates were then analyzed by electrospray ionization mass spectrometry (ESI‐MS) to simultaneously detect all the metabolites bound. Such a procedure applied to ten different proteins demonstrated that 50–400 ng of cross‐linked protein is enough to obtain ion intensities from metabolites that are well distinguishable above noise. The compatibility of microplates and different microarray designs with MS detection is discussed. Copyright © 2003 John Wiley & Sons, Ltd.