Monte Carlo study of the dependence of the KAP-meter calibration coefficient on beam aperture, x-ray tube voltage and reference plane
Authors:
- A MalusekAMA Malusek
- J P LarssonJLJ P Larsson
- G Alm CarlssonGCG Alm Carlsson
- 30 January 2007
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (4) , 1157-1170
Abstract
The Monte Carlo method was used to study the dependence of the calibration coefficient on the tube voltage, beam aperture and reference plane in simplified over-couch geometries modelling VacuTec's type 70157 KAP-meter both with and without an additional filter. The MCNP5 code was used to calculate (i) energy imparted to air cavities of the KAP-meter and (ii) spatial distribution of air collision kerma at entrance and exit planes of the KAP-meter and at a plane close to the patient. From these data, the air kerma area product and calibration coefficient were calculated and their dependence on the tube voltage and beam aperture was analysed. It was found that the variation of the calibration coefficient as a function of tube voltage was up to 40% when the additional filter was used. The additional filter placed closely in front of the KAP-meter decreased the calibration coefficient for the patient plane by about 10% compared to the ideal additional filter. The effect of the beam aperture was small at the patient plane and negligible for the exit plane.Keywords
This publication has 10 references indexed in Scilit:
- Monte Carlo dose calculations in homogeneous media and at interfaces: A comparison between GEPTS, EGSnrc, MCNP, and measurementsMedical Physics, 2002
- Ionization chambers for measuring air kerma integrated over beam area. Deviations in calibration values using simplified calibration methodsPhysics in Medicine & Biology, 1998
- A new Diamentor for measuring kerma‐area product and air‐kerma simultaneouslyMedical Physics, 1997
- Estimation of effective dose to the patient during medical X-ray examinations from measurements of the dose-area productPhysics in Medicine & Biology, 1992
- Dosimetry in Diagnostic Radiology and Computerized Tomography1990
- Re-evaluation of the W value for electrons in dry airPhysics in Medicine & Biology, 1987
- Energy imparted to the patient in diagnostic radiology: calculation of conversion factors for determining the energy imparted from measurements of the air collision kerma integrated over beam areaPhysics in Medicine & Biology, 1984
- Quantities and concepts used in radiation dosimetryThe International Journal of Applied Radiation and Isotopes, 1982
- An evaluation of the Diamentor transmission ionisation chamber in indicating exposure-area product (R cm2) during diagnostic radiological examinationsPhysics in Medicine & Biology, 1982
- Integral Absorbed Doses in Roentgen Diagnostic Procedures: I. The dosemeterActa Radiologica: Therapy, Physics, Biology, 1965