Latest Publications
- 1 May 2008
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 90 (2) , 167-178
CTmod—A toolkit for Monte Carlo simulation of projections including scatter in computed tomography
- 1 May 2008
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 90 (2) , 167-178
CTmod—A toolkit for Monte Carlo simulation of projections including scatter in computed tomography
- 30 January 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (4) , 1157-1170
Monte Carlo study of the dependence of the KAP-meter calibration coefficient on beam aperture, x-ray tube voltage and reference plane
The Monte Carlo method was used to study the dependence of the calibration coefficient on the tube voltage, beam aperture and reference plane in simplified over-couch geometries modelling VacuTec's type 70157 KAP-meter both with and without an additional filter. The MCNP5 code was used to calculate (i) energy imparted to air cavities of the KAP-meter and (ii) spatial distribution of air collision kerma at entrance and exit planes of the KAP-meter and at a plane close to the patient. From these data, the air kerma area product and calibration coefficient were calculated and their dependence on the tube voltage and beam aperture was analysed. It was found that the variation of the calibration coefficient as a function of tube voltage was up to 40% when the additional filter was used. The additional filter placed closely in front of the KAP-meter decreased the calibration coefficient for the patient plane by about 10% compared to the ideal additional filter. The effect of the beam aperture was small at the patient plane and negligible for the exit plane.
- 30 January 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (4) , 1157-1170
Monte Carlo study of the dependence of the KAP-meter calibration coefficient on beam aperture, x-ray tube voltage and reference plane
The Monte Carlo method was used to study the dependence of the calibration coefficient on the tube voltage, beam aperture and reference plane in simplified over-couch geometries modelling VacuTec's type 70157 KAP-meter both with and without an additional filter. The MCNP5 code was used to calculate (i) energy imparted to air cavities of the KAP-meter and (ii) spatial distribution of air collision kerma at entrance and exit planes of the KAP-meter and at a plane close to the patient. From these data, the air kerma area product and calibration coefficient were calculated and their dependence on the tube voltage and beam aperture was analysed. It was found that the variation of the calibration coefficient as a function of tube voltage was up to 40% when the additional filter was used. The additional filter placed closely in front of the KAP-meter decreased the calibration coefficient for the patient plane by about 10% compared to the ideal additional filter. The effect of the beam aperture was small at the patient plane and negligible for the exit plane.
- Open Access
- 17 May 2005
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 114 (1-3) , 337-340
Effect of scatter on reconstructed image quality in cone beam computed tomography: evaluation of a scatter-reduction optimisation function
The effect of scatter on reconstructed image quality in cone beam computed tomography was investigated and a function which can be used in scatter-reduction optimisation tasks was tested. Projections were calculated using the Monte Carlo method in an axially symmetric cone beam geometry consisting of a point source, water phantom and a single row of detector elements. Image reconstruction was performed using the filtered backprojection method. Image quality was assessed by the L2-norm-based difference relative to a reference image derived from (1) weighted linear attenuation coefficients and (2) projections by primary photons. It was found that the former function was strongly affected by the beam hardening artefact and did not properly reflect the amount of scatter but the latter function increased with increasing beam width, was higher for the larger phantom and exhibited properties which made it a good candidate for scatter-reduction optimisation tasks using polyenergetic beams.
- 17 May 2005
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 114 (1-3) , 337-340
Open AccessEffect of scatter on reconstructed image quality in cone beam computed tomography: evaluation of a scatter-reduction optimisation function
The effect of scatter on reconstructed image quality in cone beam computed tomography was investigated and a function which can be used in scatter-reduction optimisation tasks was tested. Projections were calculated using the Monte Carlo method in an axially symmetric cone beam geometry consisting of a point source, water phantom and a single row of detector elements. Image reconstruction was performed using the filtered backprojection method. Image quality was assessed by the L2-norm-based difference relative to a reference image derived from (1) weighted linear attenuation coefficients and (2) projections by primary photons. It was found that the former function was strongly affected by the beam hardening artefact and did not properly reflect the amount of scatter but the latter function increased with increasing beam width, was higher for the larger phantom and exhibited properties which made it a good candidate for scatter-reduction optimisation tasks using polyenergetic beams.