Compensating the effect of residual dipole energy on dielectric response for effective diagnosis of power transformer insulation
Authors:
Open Access
- 1 May 2018
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 12 (3) , 314-322
Abstract
Analysis of relaxation current is a widely accepted method for diagnosis of power transformer insulation. The accuracy of such diagnostic tool is dependent on insulation model parameters which are formulated using relaxation current. This implies that the accuracy and hence the reliability of existing insulation diagnosis methods indirectly depends on the accuracy of the recorded polarisation depolarisation current. Sometimes during field measurement relaxation current measurement equipment fails to record proper current, even after application of dc charging voltage. As per utilities, this primarily happens due to improper/loose connections (this cannot be avoided entirely due to the involvement of human factors) and such situation is usually followed by checking and rectifying improper connection. The analysis presented in this study shows that the polarisation current recorded immediately after rectifying the correction is inaccurate and leads to the erroneous diagnosis. Furthermore, it is observed that in these cases, the measured and calculated (using insulation model) values of performance parameters like dissipation factor, polarisation index, and paper‐moisture differ by a large extent. This work is aimed at removing the effect of this residual dipole energy introduced during the improper connection phase.Keywords
This publication has 14 references indexed in Scilit:
- Condition assessment of cellulosic part in power transformer insulation using transfer function zero of modified debye modelIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Prediction of moisture present in cellulosic part of power transformer insulation using transfer function of modified debye modelIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- A modified Maxwell model for characterization of relaxation processes within insulation system having non-uniform aging due to temperature gradientIEEE Transactions on Dielectrics and Electrical Insulation, 2013
- Recent Trends in the Condition Monitoring of Transformers2013
- Space charge behavior in multi-layer oil-paper insulation under different DC voltages and temperaturesIEEE Transactions on Dielectrics and Electrical Insulation, 2010
- Deriving an Equivalent Circuit of Transformers Insulation for Understanding the Dielectric Response MeasurementsIEEE Transactions on Power Delivery, 2005
- Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformersIEEE Transactions on Dielectrics and Electrical Insulation, 2004
- Applications of dielectric spectroscopy in time and frequency domain for HV power equipmentIEEE Electrical Insulation Magazine, 2003
- Dielectric spectroscopy in time and frequency domain for HV power equipment. I. Theoretical considerationsIEEE Electrical Insulation Magazine, 2003
- Electrical and chemical diagnostics of transformers insulation. A. Aged transformer samplesIEEE Transactions on Power Delivery, 1997