Simulation of thoracic endovascular aortic repair in a perfused patient-specific model of type B aortic dissection
Open Access
- 7 June 2024
- journal article
- research article
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (2) , 391-404
Abstract
Purpose: Complicated type B Aortic dissection is a severe aortic pathology that requires treatment through thoracic endovascular aortic repair (TEVAR). During TEVAR a stentgraft is deployed in the aortic lumen in order to restore blood flow. Due to the complicated pathology including an entry, a resulting dissection wall with potentially several re-entries, replicating this structure artificially has proven to be challenging thus far. Methods: We developed a 3d printed, patient-specific and perfused aortic dissection phantom with a flexible dissection flap and all major branching vessels. The model was segmented from CTA images and fabricated out of a flexible material to mimic aortic wall tissue. It was placed in a pulsatile hemodynamic flow loop. Hemodynamics were investigated through pressure and flow measurements and doppler ultrasound imaging. Surgeons performed a TEVAR intervention including stentgraft deployment under fluoroscopic guidance. Results: The flexible aortic dissection phantom was successfully incorporated in the hemodynamic flow loop, a systolic pressure of 112 mmHg and physiological flow of 4.05 L per minute was reached. Flow velocities were higher in true lumen with a up to 35.7 cm/s compared to the false lumen with a maximum of 13.3 cm/s, chaotic flow patterns were observed on main entry and reentry sights. A TEVAR procedure was successfully performed under fluoroscopy. The position of the stentgraft was confirmed using CTA imaging. Conclusions: This perfused in-vitro phantom allows for detailed investigation of the complex inner hemodynamics of aortic dissections on a patient-specific level and enables the simulation of TEVAR procedures in a real endovascular operating environment. Therefore, it could provide a dynamic platform for future surgical training and research.Keywords
Funding Information
- Heidelberger Stiftung Chirurgie (2023/606, 2023/606)
- Universitätsklinikum Heidelberg
This publication has 28 references indexed in Scilit:
- Pulsatile Flow Leads to Intimal Flap Motion and Flow Reversal in an In Vitro Model of Type B Aortic DissectionCardiovascular Engineering and Technology, 2017
- Precise treatment of aortic aneurysm by three-dimensional printing and simulation before endovascular interventionScientific Reports, 2017
- Reintervention after endovascular repair for aortic dissection: A systematic review and meta-analysisThe Journal of Thoracic and Cardiovascular Surgery, 2016
- Persistent Type I Endoleak after Endovascular Treatment with Chimney TechniqueFrontiers in Cardiovascular Medicine, 2016
- Endovascular Repair of Acute and Chronic Aortic Type B DissectionsJACC: Cardiovascular Interventions, 2016
- Evolution of Aortic Wall Thickness and Stiffness With AtherosclerosisHypertension, 2015
- Biodegradable polymeric stents for vascular application in a porcine carotid artery modelGefässchirurgie, 2015
- 2014 ESC Guidelines on the diagnosis and treatment of aortic diseasesEuropean Heart Journal, 2014
- Factors Portending Endoleak Formation After Thoracic Aortic Stent-Graft Repair of Complicated Aortic DissectionCirculation: Cardiovascular Interventions, 2009
- Learning curve analysis of thoracic endovascular aortic repair in relation to credentialing guidelinesJournal of Vascular Surgery, 2007