Lukas Mohl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lukas Mohl has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Armin Runz
DKFZ, German Cancer Research Center, Heidelberg, Germany
1 shared publication- Carl Soeren Bergt
Institute for Artificial Intelligence in Cardiovascular Medicine, University Hospital Heidelberg.
1 shared publication Christian Uhl
Department of Vascular Surgery and Endovascular Surgery, University Hospital Heidelberg, Heidelberg, Germany
1 shared publicationDittmar Böckler
Department of Vascular Surgery and Endovascular Surgery, University Hospital Heidelberg, Heidelberg, Germany
1 shared publication- Johannes Hatzl
Department of Vascular and Endovascular Surgery, University Hospital Heidelberg, 69120 Heidelberg, Germany
1 shared publication Katrin Meisenbacher
Department of Vascular Surgery and Endovascular Surgery, University Hospital Heidelberg, Heidelberg, Germany
1 shared publication
Latest Publications
- Open Access
- 7 June 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (2) , 391-404
Simulation of thoracic endovascular aortic repair in a perfused patient-specific model of type B aortic dissection
Purpose: Complicated type B Aortic dissection is a severe aortic pathology that requires treatment through thoracic endovascular aortic repair (TEVAR). During TEVAR a stentgraft is deployed in the aortic lumen in order to restore blood flow. Due to the complicated pathology including an entry, a resulting dissection wall with potentially several re-entries, replicating this structure artificially has proven to be challenging thus far. Methods: We developed a 3d printed, patient-specific and perfused aortic dissection phantom with a flexible dissection flap and all major branching vessels. The model was segmented from CTA images and fabricated out of a flexible material to mimic aortic wall tissue. It was placed in a pulsatile hemodynamic flow loop. Hemodynamics were investigated through pressure and flow measurements and doppler ultrasound imaging. Surgeons performed a TEVAR intervention including stentgraft deployment under fluoroscopic guidance. Results: The flexible aortic dissection phantom was successfully incorporated in the hemodynamic flow loop, a systolic pressure of 112 mmHg and physiological flow of 4.05 L per minute was reached. Flow velocities were higher in true lumen with a up to 35.7 cm/s compared to the false lumen with a maximum of 13.3 cm/s, chaotic flow patterns were observed on main entry and reentry sights. A TEVAR procedure was successfully performed under fluoroscopy. The position of the stentgraft was confirmed using CTA imaging. Conclusions: This perfused in-vitro phantom allows for detailed investigation of the complex inner hemodynamics of aortic dissections on a patient-specific level and enables the simulation of TEVAR procedures in a real endovascular operating environment. Therefore, it could provide a dynamic platform for future surgical training and research.
- 7 June 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (2) , 391-404
Open AccessSimulation of thoracic endovascular aortic repair in a perfused patient-specific model of type B aortic dissection
Purpose: Complicated type B Aortic dissection is a severe aortic pathology that requires treatment through thoracic endovascular aortic repair (TEVAR). During TEVAR a stentgraft is deployed in the aortic lumen in order to restore blood flow. Due to the complicated pathology including an entry, a resulting dissection wall with potentially several re-entries, replicating this structure artificially has proven to be challenging thus far. Methods: We developed a 3d printed, patient-specific and perfused aortic dissection phantom with a flexible dissection flap and all major branching vessels. The model was segmented from CTA images and fabricated out of a flexible material to mimic aortic wall tissue. It was placed in a pulsatile hemodynamic flow loop. Hemodynamics were investigated through pressure and flow measurements and doppler ultrasound imaging. Surgeons performed a TEVAR intervention including stentgraft deployment under fluoroscopic guidance. Results: The flexible aortic dissection phantom was successfully incorporated in the hemodynamic flow loop, a systolic pressure of 112 mmHg and physiological flow of 4.05 L per minute was reached. Flow velocities were higher in true lumen with a up to 35.7 cm/s compared to the false lumen with a maximum of 13.3 cm/s, chaotic flow patterns were observed on main entry and reentry sights. A TEVAR procedure was successfully performed under fluoroscopy. The position of the stentgraft was confirmed using CTA imaging. Conclusions: This perfused in-vitro phantom allows for detailed investigation of the complex inner hemodynamics of aortic dissections on a patient-specific level and enables the simulation of TEVAR procedures in a real endovascular operating environment. Therefore, it could provide a dynamic platform for future surgical training and research.