Towards Bacteria Counting in DI Water of Several Microliters or Growing Suspension Using Impedance Biochips
Authors:
- Mahdi KianiMKMahdi Kiani
- Astrid TannertATAstrid Tannert
- Nan DuNDNan Du
- Uwe HübnerUHUwe Hübner
- Ilona SkorupaISIlona Skorupa
- Danilo BürgerDBDanilo Bürger
- Xianyue ZhaoXZXianyue Zhao
- Daniel BlaschkeDBDaniel Blaschke
- Lars RebohleLRLars Rebohle
- Charaf CherkoukCCCharaf Cherkouk
- Ute NeugebauerUNUte Neugebauer
- Oliver G. SchmidtOSOliver G. Schmidt
Open Access
- 23 July 2020
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 10 (8) , 82
Abstract
We counted bacterial cells of E. coli strain K12 in several-microliter DI water or in several-microliter PBS in the low optical density (OD) range (OD = 0.05–1.08) in contact with the surface of Si-based impedance biochips with ring electrodes by impedance measurements. The multiparameter fit of the impedance data allowed calibration of the impedance data with the concentration cb of the E. coli cells in the range of cb = 0.06 to 1.26 × 109 cells/mL. The results showed that for E. coli in DI water and in PBS, the modelled impedance parameters depend linearly on the concentration of cells in the range of cb = 0.06 to 1.26 × 109 cells/mL, whereas the OD, which was independently measured with a spectrophotometer, was only linearly dependent on the concentration of the E. coli cells in the range of cb = 0.06 to 0.50 × 109 cells/mL.Keywords
Funding Information
- Sächsische Aufbaubank (100260515)
- Bundesministerium für Wirtschaft und Energie (03THW12K11)
- Deutsche Forschungsgemeinschaft (FKZ: PO 563/29-1, BA 1601/10-1)
This publication has 22 references indexed in Scilit:
- P-N Junction-Based Si Biochips with Ring Electrodes for Novel Biosensing ApplicationsBiosensors, 2019
- Development of a Miniaturized and Selective Impedance Sensor for Real-Time Slime Monitoring in Pipes and TanksSensors and Actuators B: Chemical, 2019
- General calibration of microbial growth in microplate readersScientific Reports, 2016
- Characterization of subcellular morphology of single yeast cells using high frequency microfluidic impedance cytometerLab on a Chip, 2013
- Selective detection of bacteria by a dielectrophoretic impedance measurement method using an antibody-immobilized electrode chipSensors and Actuators B: Chemical, 2006
- Monitoring of yeast cell concentration using a micromachined impedance sensorSensors and Actuators B: Chemical, 2006
- Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizingLab on a Chip, 2001
- Impedance microbiology: quantification of bacterial content in milk by means of capacitance growth curvesJournal of Microbiological Methods, 1999
- Quantitative reflection contrast microscopy of living cells.Journal of Cell Biology, 1979
- Accuracy and Speed in Counting Agar PlatesJournal of Food Protection, 1977