Compact dual-mode diffuse optical system for blood perfusion monitoring in a porcine model of microvascular tissue flaps
Open Access
- 14 December 2017
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (12) , 121609-14
Abstract
In reconstructive surgery, the ability to detect blood flow interruptions to grafted tissue represents a critical step in preventing postsurgical complications. We have developed and pilot tested a compact, fiber-based device that combines two complimentary modalities—diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy—to quantitatively monitor blood perfusion. We present a proof-of-concept study on an in vivo porcine model ( ). With a controllable arterial blood flow supply, occlusion studies ( ) were performed on surgically isolated free flaps while the device simultaneously monitored blood flow through the supplying artery as well as flap perfusion from three orientations: the distal side of the flap and two transdermal channels. Further studies featuring long-term monitoring, arterial failure simulations, and venous failure simulations were performed on flaps that had undergone an anastomosis procedure ( ). Additionally, benchtop verification of the DCS system was performed on liquid flow phantoms. Data revealed relationships between diffuse optical measures and state of occlusion as well as the ability to detect arterial and venous compromise. The compact construction of the device, along with its noninvasive and quantitative nature, would make this technology suitable for clinical translation.
Keywords
Funding Information
- National Institutes of Health (R44-DE021935)
This publication has 40 references indexed in Scilit:
- Quantitative assessment of partial vascular occlusions in a swine pedicle flap model using spatial frequency domain imagingBiomedical Optics Express, 2013
- Diagnostic power of diffuse reflectance spectroscopy for targeted detection of breast lesions with microcalcificationsProceedings of the National Academy of Sciences, 2012
- Validation of diffuse correlation spectroscopic measurement of cerebral blood flow using phase-encoded velocity mapping magnetic resonance imagingJournal of Biomedical Optics, 2012
- Influences of tissue absorption and scattering on diffuse correlation spectroscopy blood flow measurementsBiomedical Optics Express, 2011
- Diffuse optics for tissue monitoring and tomographyReports on Progress in Physics, 2010
- Advances in quantitative UV–visible spectroscopy for clinical and pre-clinical application in cancerCurrent Opinion in Biotechnology, 2009
- 25 ns software correlator for photon and fluorescence correlation spectroscopyReview of Scientific Instruments, 2003
- Differentiation Between Arterial and Venous Vessel Occlusion by Simultaneous Measurement with Laser Doppler Flowmetry and PhotoplethysmographyJournal of Reconstructive Microsurgery, 1999
- Spatially varying dynamical properties of turbid media probed with diffusing temporal light correlationJournal of the Optical Society of America A, 1997
- Effects of finite laser coherence in quasielastic multiple scatteringPhysical Review A, 1991