  • Imaging Results From a Direct Conversion X-Ray Detector With TlBr and CMOS Pixel Array

    by J. F. Christian, M. S. Squillante, M. J. Breen, O. Maksimov, H. Kim, E. Weststrate, A. Kargar, V. Nagarkar, M. Dallimore, A. Pil-Ali, et al.

    This work explores the fabrication and characterization of X-ray imaging devices using a single-crystal TlBr sample (8 mm × 8 mm × 10 mm) and polycrystalline TlBr film (approximately 0.38-mm thick), both bonded to a Libra-1 Complementary Metal-Oxide-Semiconductor (CMOS) readout chip connected to the BrillianSe 1M readout system. The BrillianSe 1M, designed for X-ray radiography by KA Imaging, features a 10 mm × 11 mm readout chip with a 7.8 μm pixel pitch and a 7.8 mm × 7.8 mm active area. The work below describes the characterization of test and imaging devices. The characterization includes current-voltage (IV) curves and impedance spectra, longevity measurements of the X-ray response and leakage current, and imaging characterization with light-emitting diodes (LED) and X-rays. The resistivity of 3x1010 Ω-cm was estimated for a polycrystalline film sample. Following five weeks, the leakage current decreased from 670 to 6.4 nA, while the X-ray photocurrent decreased from 28 to 4 nA. Both the single crystal and polycrystalline imaging devices resolved 0.3-mm-diameter holes in a Tungsten composite mask when irradiated with 90 kVp (100 μA tube current) X-rays. Effects at the interface can be seen with both LED and X-rays. The images provide critical information for optimizing the fabrication process and device longevity.

  • TlBr Films for Direct Digital Radiography

    by M. S. Squillante, M. J. Breen, J. F. Christian, A. Kargar, Y. Ogorodnik, F. Robertson, V. Nagarkar, M. R. Squillante, L. Cirignano, O. Maksimov, et al.

    The detector that converts X-ray intensity into a digitized electronic signal, processed into an image, often limits the performance of modern X-ray imaging systems, whether for medical, research, or industrial applications. Digital radiography (DR) uses the following two types of detectors: 1) indirect detectors, where a scintillating film converts X-rays into an optical signal read by an optical detector, and 2) direct detectors using semiconductors. Semiconductor X-ray detector technology typically uses a silicon wafer, an amorphous selenium (a-Se) film, or a relatively thin cadmium zinc telluride (CZT) crystal bump bonded to a readout platform. Although the use of a-Se and CZT improves the attenuation coefficient beyond that of silicon, a further increase in performance is highly desirable for improved imaging of higher-energy X-rays (greater than 20 keV). This article presents results on thallium bromide (TlBr) films coupled to a read-out integrated circuit (ROIC). TlBr, an attractive material for hard X-ray imaging due to its high atomic number and high density, achieves an image resolution of $20 \mu $ m as a 1 cm ${}^{2} \times 100$ - $\mu $ m-thick columnar film deposited on CMOS ROIC.


  • Performance characterization of 5x5x12 mm3 virtual Frisch-Grid TlBr detectors

    by Aleksey E. Bolotnikov, Conner Brown, Gabriella A. Carini, James F. Christian, Leonard J. Cirignano, Connie-Rose Deane, Alfred Dellapenna, Jack Fried, Sven C. Herrmann, Alireza Kargar, et al.

    We present the results from testing over 100 5x5x12 mm3 TlBr detectors configured as 3D position-sensitive virtual Frisch-grid (VFG) detectors with platinum contacts. The primary objective was to comprehensively understand factors limiting performance and long-term response variations in these detectors. The incorporation of 3D position sensitivity allowed us to monitor internal changes in charge collection efficiency after applying voltage, and to correlate them with device performance changes. The biased detectors underwent defect distribution alterations due to electric field-enhanced ion migration. Our results are based on an extensive dataset obtained from TlBr crystals produced by Radiation Monitoring Devices (RMD). These measurements were part of our development of a handheld isotope identifier based on an array of position-sensitive TlBr detectors, supported by the Department of Homeland Security, Countering Weapons of Mass Destruction Office. The majority of the detectors exhibited a common trend of performance improvement within 1-2 weeks, stabilization for some period of time, then a slow degradation; however, some detectors deviated from this pattern.

  • Open Access

    Compact dual-mode diffuse optical system for blood perfusion monitoring in a porcine model of microvascular tissue flaps

    by Seung Yup Lee, Julia M. Pakela, Michael C. Helton, Karthik Vishwanath, Yooree G. Chung, Noah J. Kolodziejski, Christopher J. Stapels, Daniel R. McAdams, Daniel E. Fernandez, James F. Christian, et al.

    In reconstructive surgery, the ability to detect blood flow interruptions to grafted tissue represents a critical step in preventing postsurgical complications. We have developed and pilot tested a compact, fiber-based device that combines two complimentary modalities—diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy—to quantitatively monitor blood perfusion. We present a proof-of-concept study on an in vivo porcine model ( n = 8 ). With a controllable arterial blood flow supply, occlusion studies ( n = 4 ) were performed on surgically isolated free flaps while the device simultaneously monitored blood flow through the supplying artery as well as flap perfusion from three orientations: the distal side of the flap and two transdermal channels. Further studies featuring long-term monitoring, arterial failure simulations, and venous failure simulations were performed on flaps that had undergone an anastomosis procedure ( n = 4 ). Additionally, benchtop verification of the DCS system was performed on liquid flow phantoms. Data revealed relationships between diffuse optical measures and state of occlusion as well as the ability to detect arterial and venous compromise. The compact construction of the device, along with its noninvasive and quantitative nature, would make this technology suitable for clinical translation.


  • Open Access

    In vivo preclinical verification of a multimodal diffuse reflectance and correlation spectroscopy system for sensing tissue perfusion

    by Julia M. Pakela, Seung Yup Lee, Taylor L. Hedrick, Karthik Vishwanath, Michael C. Helton, Yooree G. Chung, Noah J. Kolodziejski, Christopher J. Stapels, Daniel R. McAdams, Daniel E. Fernandez, et al.

    In reconstructive surgery, impeded blood flow in microvascular free flaps due to a compromise in arterial or venous patency secondary to blood clots or vessel spasms can rapidly result in flap failures. Thus, the ability to detect changes in microvascular free flaps is critical. In this paper, we report progress on in vivo pre-clinical testing of a compact, multimodal, fiber-based diffuse correlation and reflectance spectroscopy system designed to quantitatively monitor tissue perfusion in a porcine model’s surgically-grafted free flap. We also describe the device’s sensitivity to incremental blood flow changes and discuss the prospects for continuous perfusion monitoring in future clinical translational studies.


  • Effects of Proton Radiation on Noise Performance in Solid-State Photomultipliers

    by Xiao Jie Chen, Erik B. Johnson, Christopher J. Stapels, Dan Fernandez, Matt Podolsky, Sam Vogel, James F. Christian

    Solid-state photomultiplier (SSPM) devices are a viable alternative to photomultiplier tubes for nuclear and space radiation detection and science instruments. Noise terms such as dark noise, cross talk, after-pulsing, and their radiation sensitivity directly affect the photodetector performance for harsh environment applications. This paper presents the results from proton radiation-hardness tests conducted for two sets of SSPMs designed and fabricated in two different commercial complementary metal oxide silicon (CMOS) processes: 0.18-μm and 0.8 μm. Following proton exposures to the SSPMs at 100 krad, 500 krad and 1 Mrad, the measured proton induced dark noise at unity gain is higher in 0.18-μm SSPMs, but the dark current in Geiger mode is higher in 0.8 μm devices. The results and analysis suggest a higher proton-induced surface/sidewall dark current than bulk dark current in 0.18-μm samples. The proton induced bulk defect densities are similar between 0.18-μm and 0.8 μm SSPMs. Reasonable excess noise measurement results were obtained in 0.18-μm SSPM samples, and inter-pixel cross talk and after-pulsing remain statistically unchanged after proton exposure. The radiation insensitivity of after-pulsing noise suggests that shallow trap density responsible for after-pulsing is not significantly affected by proton irradiations in these CMOS high gain photodetectors.


  • Characterization of CMOS Solid-State Photomultiplier for a Digital Radiation Rate Meter

    by C. J. Stapels, F. L. Augustine, M. R. Squillante, J. F. Christian

    An approach to detect the light from scintillation materials using an array of small photon counting detectors, referred to as a "solid-state photomultiplier" (SSPM), detects light from a scintillation material to provide a sensitive radiation monitor. Each pixel acts as a binary photon detector, but the summed output is an analog representation of the total photon intensity, which is proportional to the energy of the gamma ray. We have successfully fabricated arrays of GPD pixels in a CMOS environment, which makes possible the production of miniaturized arrays integrated with the detector electronics in a small silicon chip. This detector technology allows for a substantial cost reduction while preserving the energy resolution needed for radiological measurements. In this work, we demonstrate the operation of a 100-pixel array in reading an LSO scintillation crystal. In addition, we present the energy spectra corrected for saturation effects and examine the effects of cross talk on the performance of the SSPM.