Biomechanical performance of an intramedullary Echidna pin for fixation of comminuted mid‐shaft clavicle fractures
- 3 September 2019
- journal article
- research article
- Published by Wiley in Anz Journal of Surgery
- Vol. 89 (10) , 1308-1313
Abstract
Background Surgical fixation of comminuted mid‐shaft clavicle fractures commonly employs intramedullary devices; however, pins with smooth surfaces are prone to migration, whilst threaded pins can be challenging to remove post‐operatively. The aim of this study was to evaluate the biomechanical performance of fractured clavicles repaired using a novel intramedullary Echidna pin device and a non‐threaded Knowles pin. The Echidna pin features retractable spines that engage with the bone to minimize migration and facilitate ease of device removal. Methods A total of 28 cadaveric clavicle specimens were harvested and a mid‐shaft wedge‐shaped osteotomy was performed to simulate a comminuted butterfly fragment. Specimens were allocated randomly to either the Echidna pin or Knowles pin fracture repair groups. Following surgery, eight specimens in each group underwent 200 cycles of four‐point bending, whilst six specimens in each group underwent torsional testing and pull‐out. Cyclic construct bending stiffness, torsional stiffness and ultimate strength were recorded. Results Echidna pin intramedullary repair constructs showed significantly greater bending stiffness (mean difference 0.55 N.m/°, 95% confidence interval −0.96, −0.14, P = 0.01) and pull‐out strength (mean difference 146.03 N, 95% confidence interval 29.14, 262.92, P = 0.019) in comparison to Knowles pin constructs. There was no significant difference in torsional stiffness between Echidna pin and Knowles pin repair constructs (P > 0.05). Conclusion The intramedullary Echidna pin device, which exhibits greater bending strength and pull‐out strength than that of the Knowles pin, may produce a more stable clavicle fracture reduction compared to that of commercially available threadless intramedullary pins.Keywords
This publication has 30 references indexed in Scilit:
- Excessive Complications of Open Intramedullary Nailing of Midshaft Clavicle Fractures With the Rockwood Clavicle PinClinical Orthopaedics and Related Research, 2011
- Rationale and design of the plate or pin (pop) study for dislocated midshaft clavicular fractures: study protocol for a randomised controlled trialTrials, 2011
- Comparison of Plates versus Intramedullary Nails for Fixation of Displaced Midshaft Clavicular FracturesJournal of Trauma: Injury, Infection & Critical Care, 2010
- Locked intramedullary fixation vs plating for displaced and shortened mid-shaft clavicle fractures: A randomized clinical trialJournal of Shoulder and Elbow Surgery, 2010
- Malunion after midshaft clavicle fractures in adultsActa Orthopaedica, 2010
- A biomechanical study of plate versus intramedullary devices for midshaft clavicle fixationJournal of Orthopaedic Surgery and Research, 2008
- Biomechanical Evaluation of Clavicle Fracture Plating Techniques: Does a Locking Plate Provide Improved Stability?Journal of Orthopaedic Trauma, 2008
- Surgical treatment of midclavicular fractures: a prospective comparison of Knowles pinning and plate fixationInternational Orthopaedics, 2007
- Flexible intramedullary nailing for stabilization of displaced midshaft clavicle fractures: Technique and results in 87 patientsActa Orthopaedica, 2007
- Fixation of mid-third clavicular fractures with Knowles pins: 78 patients followed for 2-7 yearsActa Orthopaedica, 2002