Lachlan S. Huntington
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Lachlan S. Huntington has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- David Charles Ackland
Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria 3010, Australia
4 shared publications Brian M. Devitt
Epworth HealthCare, OrthoSport Victoria, OrthoSport Victoria Res Unit, Melbourne, Vic 3121, Australia
2 shared publicationsJonathon Caldow
Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria, 3010, Australia
2 shared publicationsLachlan Batty
Department of Orthopaedic Surgery, Western Health, Footscray Hospital, Melbourne, Australia
2 shared publicationsMartin Richardson
Department of Orthopaedic Surgery, Epworth Healthcare, Richmond, Victoria, 3121, Australia
2 shared publications- Stephen K. Tham
Victorian Hand Surgery Associates, Fitzroy, Australia
2 shared publications
Latest Publications
- Open Access
- 24 March 2023
- Published by Springer Nature in Trials
- Vol. 24 (1) , 1-15
Suture-tape augmentation of anterior cruciate ligament reconstruction: a prospective, randomised controlled trial (STACLR)
Background: Anterior cruciate ligament (ACL) reconstruction aims to restore anteroposterior and rotatory stability to the knee following ACL injury. This requires the graft to withstand the forces applied during the process of ligamentisation and the rehabilitative period. We hypothesise that the use of suture tape augmentation of single bundle ACL reconstruction (ACLR) will reduce residual knee laxity and improve patient-reported outcomes at 2-year follow-up. We will conduct a 1:1 parallel arm single-centre randomised controlled trial comparing suture tape augmented ACLR to standard ACLR technique. Methods: The study design will be a parallel arm 1:1 allocation ratio randomised controlled trial. Sixty-six patients aged 18 and over waitlisted for primary ACLR will be randomised. Patients requiring osteotomy and extra-articular tenodesis and who have had previous contralateral ACL rupture or repair of meniscal or cartilage pathology that modifies the post-operative rehabilitation will be excluded. The primary outcome measure will be the side-to-side difference in anterior tibial translation (measured on the GNRB arthrometer) at 24 months post-surgery. GNRB arthrometer measures will also be taken preoperatively, at 3 months and 12 months post-surgery. Secondary outcomes will include patient-reported outcome measures (PROMs) collected online, including quality of life, activity and readiness to return to sport, complication rates (return to theatre, graft failure and rates of sterile effusion), examination findings and return to sport outcomes. Participants will be seen preoperatively, at 6 weeks, 3 months, 12 months and 24 months post-surgery. Participants and those taking arthrometer measures will be blinded to allocation. Discussion: This will be the first randomised trial to investigate the effect of suture-tape augmentation of ACLR on either objective or subjective outcome measures. The use of suture-tape augmentation in ACLR has been associated with promising biomechanical and animal-level studies, exhibiting equivalent complication profiles to the standard technique, with initial non-comparative clinical studies establishing possible areas of advantage for the technique. The successful completion of this trial will allow for an improved understanding of the in situ validity of tape augmentation whilst potentially providing a further platform for surgical stabilisation of the ACL graft. Trial registration: Australia New Zealand Clinical Trial Registry ACTRN12621001162808. Universal Trial Number (UTN): U1111-1268-1487. Registered prospectively on 27 August 2021
- 24 March 2023
- Published by Springer Nature in Trials
- Vol. 24 (1) , 1-15
Open AccessSuture-tape augmentation of anterior cruciate ligament reconstruction: a prospective, randomised controlled trial (STACLR)
Background: Anterior cruciate ligament (ACL) reconstruction aims to restore anteroposterior and rotatory stability to the knee following ACL injury. This requires the graft to withstand the forces applied during the process of ligamentisation and the rehabilitative period. We hypothesise that the use of suture tape augmentation of single bundle ACL reconstruction (ACLR) will reduce residual knee laxity and improve patient-reported outcomes at 2-year follow-up. We will conduct a 1:1 parallel arm single-centre randomised controlled trial comparing suture tape augmented ACLR to standard ACLR technique. Methods: The study design will be a parallel arm 1:1 allocation ratio randomised controlled trial. Sixty-six patients aged 18 and over waitlisted for primary ACLR will be randomised. Patients requiring osteotomy and extra-articular tenodesis and who have had previous contralateral ACL rupture or repair of meniscal or cartilage pathology that modifies the post-operative rehabilitation will be excluded. The primary outcome measure will be the side-to-side difference in anterior tibial translation (measured on the GNRB arthrometer) at 24 months post-surgery. GNRB arthrometer measures will also be taken preoperatively, at 3 months and 12 months post-surgery. Secondary outcomes will include patient-reported outcome measures (PROMs) collected online, including quality of life, activity and readiness to return to sport, complication rates (return to theatre, graft failure and rates of sterile effusion), examination findings and return to sport outcomes. Participants will be seen preoperatively, at 6 weeks, 3 months, 12 months and 24 months post-surgery. Participants and those taking arthrometer measures will be blinded to allocation. Discussion: This will be the first randomised trial to investigate the effect of suture-tape augmentation of ACLR on either objective or subjective outcome measures. The use of suture-tape augmentation in ACLR has been associated with promising biomechanical and animal-level studies, exhibiting equivalent complication profiles to the standard technique, with initial non-comparative clinical studies establishing possible areas of advantage for the technique. The successful completion of this trial will allow for an improved understanding of the in situ validity of tape augmentation whilst potentially providing a further platform for surgical stabilisation of the ACL graft. Trial registration: Australia New Zealand Clinical Trial Registry ACTRN12621001162808. Universal Trial Number (UTN): U1111-1268-1487. Registered prospectively on 27 August 2021
- Open Access
- 7 February 2023
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- Vol. 5 (2) , e337-e343
The Effect of Tibial Tunnel Drilling Technique on Retained Intra‐Articular Bone Debris Following Anterior Cruciate Ligament Reconstruction
Purpose: To assess the effect of tibial tunnel drilling technique (retro‐drilled bone socket vs full tibial tunnel) on the presence and grade of postoperative, intra‐articular bone debris following primary hamstring anterior cruciate ligament (ACL) reconstruction. Methods: This was a retrospective cohort study of primary hamstring autograft ACL reconstructions performed by 2 surgeons. Two blinded independent reviewers assessed the presence and length of retained intra‐articular bone debris on the immediate postoperative lateral radiograph. Debris was graded according to a predefined 5‐point ordinal grading system: grade 0 (no debris) to IV (severe debris). Results were analyzed according to the type of tibial tunnel; retro‐drilled socket or full tibial tunnel using Kappa statistics and the Mann–Whitney U test. Results: Sixty‐five patients undergoing primary hamstring ACL were included (39 tibial socket: 26 full tibial tunnel). Bone debris was observed among the tibial socket technique in 29 of 39 instances (74.3%), compared with 14 of 26 (53.8%) instances for the full tibial tunnel technique ( P = .09). Where there was measurable debris present, the tibial socket group had a mean length of bone debris of 13.7 ± 6.2 mm as compared with the full tibial tunnel, 10.0 ± 4.7 mm ( P = .165). There were significant differences in bone debris gradings between the 2 treatment groups, with tibial sockets having an overall greater grade ( P = .04). Conclusions: A difference in the presence of, or length of, retained bone debris on the postoperative lateral radiograph was not demonstrated between the retro‐drilled bone socket and full tibial tunnel techniques. However, when bone debris was present, greater grades of debris were seen in the retro‐drilled socket group. Level of Evidence: III, retrospective, comparative study.
- 7 February 2023
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- Vol. 5 (2) , e337-e343
Open AccessThe Effect of Tibial Tunnel Drilling Technique on Retained Intra‐Articular Bone Debris Following Anterior Cruciate Ligament Reconstruction
Purpose: To assess the effect of tibial tunnel drilling technique (retro‐drilled bone socket vs full tibial tunnel) on the presence and grade of postoperative, intra‐articular bone debris following primary hamstring anterior cruciate ligament (ACL) reconstruction. Methods: This was a retrospective cohort study of primary hamstring autograft ACL reconstructions performed by 2 surgeons. Two blinded independent reviewers assessed the presence and length of retained intra‐articular bone debris on the immediate postoperative lateral radiograph. Debris was graded according to a predefined 5‐point ordinal grading system: grade 0 (no debris) to IV (severe debris). Results were analyzed according to the type of tibial tunnel; retro‐drilled socket or full tibial tunnel using Kappa statistics and the Mann–Whitney U test. Results: Sixty‐five patients undergoing primary hamstring ACL were included (39 tibial socket: 26 full tibial tunnel). Bone debris was observed among the tibial socket technique in 29 of 39 instances (74.3%), compared with 14 of 26 (53.8%) instances for the full tibial tunnel technique ( P = .09). Where there was measurable debris present, the tibial socket group had a mean length of bone debris of 13.7 ± 6.2 mm as compared with the full tibial tunnel, 10.0 ± 4.7 mm ( P = .165). There were significant differences in bone debris gradings between the 2 treatment groups, with tibial sockets having an overall greater grade ( P = .04). Conclusions: A difference in the presence of, or length of, retained bone debris on the postoperative lateral radiograph was not demonstrated between the retro‐drilled bone socket and full tibial tunnel techniques. However, when bone debris was present, greater grades of debris were seen in the retro‐drilled socket group. Level of Evidence: III, retrospective, comparative study.
- Open Access
- 1 November 2021
- Published by Elsevier in Journal of ISAKOS
- Vol. 6 (6) , 333-338
Risk assessment and management of primary patellar dislocation is complex and multifactorial: a survey of Australian knee surgeons
Objectives Recurrent patellar instability following first-time lateral patellar dislocation is associated with a variety of bony, soft tissue and patient-related risk factors. The specific management of recurrent dislocation may vary depending on the presence and combination of these factors as well as the treating physician’s interpretation of these. Therefore, this study aimed to determine which factors Australian knee surgeons regard as increasing the risk of recurrence following first-time patellar dislocation and to characterise the surgical decision-making process of these surgeons in the management of lateral patellar instability. Methods An online survey was sent to all active members of the Australian Knee Society (AKS). The survey addressed (i) risk factors for recurrence following first-time patellar dislocation and (ii) the surgical decision-making process in treating patellar instability. Results Seventy-seven per cent (53 of 69) Australian Knee Society members responded. Factors identified by respondents as significantly increasing the risk of recurrence were a history of contralateral recurrent patellar dislocation (74% respondents), an atraumatic injury mechanism (57%), trochlear dysplasia (49%) younger age (45%), patella alta (43%) and generalised ligamentous laxity (42%). Forty-four per cent replied that there may be an indication for surgical intervention following first-time patellar dislocation with no apparent loose body present. All respondents would recommend operative management of recurrent patellar dislocation after a third episode, with 45% of surgeons recommending surgery after a second episode. The most common surgical procedures performed by respondents were medial patellofemoral ligament (MPFL) reconstruction (94%), tibial tuberosity medialisation (91%) and tibial tuberosity distalisation (85%). Only 23% of respondents consider trochleoplasty for primary surgical intervention. Conclusion Surgeons identified a large number of factors that they use to assess risk of recurrence following first-time patellar dislocation, many of which are not supported by the literature. The two highest ranked factors (history of contralateral recurrent patellar dislocation and an atraumatic injury mechanism) are without a significant evidence base. There was considerable variation in the criteria used to make the decision to perform a patellar stabilisation procedure. MPFL reconstruction was the most commonly used procedure, either in isolation or combined with another procedure. Level of evidence Cross-sectional study; expert opinion (Level V).
- 1 November 2021
- Published by Elsevier in Journal of ISAKOS
- Vol. 6 (6) , 333-338
Open AccessRisk assessment and management of primary patellar dislocation is complex and multifactorial: a survey of Australian knee surgeons
Objectives Recurrent patellar instability following first-time lateral patellar dislocation is associated with a variety of bony, soft tissue and patient-related risk factors. The specific management of recurrent dislocation may vary depending on the presence and combination of these factors as well as the treating physician’s interpretation of these. Therefore, this study aimed to determine which factors Australian knee surgeons regard as increasing the risk of recurrence following first-time patellar dislocation and to characterise the surgical decision-making process of these surgeons in the management of lateral patellar instability. Methods An online survey was sent to all active members of the Australian Knee Society (AKS). The survey addressed (i) risk factors for recurrence following first-time patellar dislocation and (ii) the surgical decision-making process in treating patellar instability. Results Seventy-seven per cent (53 of 69) Australian Knee Society members responded. Factors identified by respondents as significantly increasing the risk of recurrence were a history of contralateral recurrent patellar dislocation (74% respondents), an atraumatic injury mechanism (57%), trochlear dysplasia (49%) younger age (45%), patella alta (43%) and generalised ligamentous laxity (42%). Forty-four per cent replied that there may be an indication for surgical intervention following first-time patellar dislocation with no apparent loose body present. All respondents would recommend operative management of recurrent patellar dislocation after a third episode, with 45% of surgeons recommending surgery after a second episode. The most common surgical procedures performed by respondents were medial patellofemoral ligament (MPFL) reconstruction (94%), tibial tuberosity medialisation (91%) and tibial tuberosity distalisation (85%). Only 23% of respondents consider trochleoplasty for primary surgical intervention. Conclusion Surgeons identified a large number of factors that they use to assess risk of recurrence following first-time patellar dislocation, many of which are not supported by the literature. The two highest ranked factors (history of contralateral recurrent patellar dislocation and an atraumatic injury mechanism) are without a significant evidence base. There was considerable variation in the criteria used to make the decision to perform a patellar stabilisation procedure. MPFL reconstruction was the most commonly used procedure, either in isolation or combined with another procedure. Level of evidence Cross-sectional study; expert opinion (Level V).
- 21 May 2021
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 47 (2) , 172-178
Biomechanical comparison of intramedullary screw fixation, dorsal plating and K-wire fixation for stable metacarpal shaft fractures
We compared four methods of metacarpal shaft fixation: 2.2 mm intramedullary headless compression screw; 3.0 mm intramedullary headless compression screw; intramedullary K-wire fixation; and dorsal plate fixation. Transverse mid-diaphyseal fractures were created in 64 metacarpal sawbones and were assigned into four groups. Peak load to failure and stiffness were measured in cantilever bending and torsion. We found that dorsal plating had the highest peak load to failure. However, initial bending stiffness of the 3.0 mm intramedullary headless compression screw was higher than that of the dorsal plates. In torsion testing, dorsal plating had the highest peak torque, but there was no significant difference in torsional stiffness between the plate and intramedullary headless compression screw constructs. We concluded that intramedullary headless compression screw fixation is biomechanically superior to K-wires in cantilever bending and torsion; however, it is less stable than dorsal plating. In our study, the initial stability provided by K-wire fixation was sufficient to cope with expected loads in the early rehabilitation period, whereas dorsal plates and IHCS constructs provided stability far in excess of what is required.
- 21 May 2021
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 47 (2) , 172-178
Biomechanical comparison of intramedullary screw fixation, dorsal plating and K-wire fixation for stable metacarpal shaft fractures
We compared four methods of metacarpal shaft fixation: 2.2 mm intramedullary headless compression screw; 3.0 mm intramedullary headless compression screw; intramedullary K-wire fixation; and dorsal plate fixation. Transverse mid-diaphyseal fractures were created in 64 metacarpal sawbones and were assigned into four groups. Peak load to failure and stiffness were measured in cantilever bending and torsion. We found that dorsal plating had the highest peak load to failure. However, initial bending stiffness of the 3.0 mm intramedullary headless compression screw was higher than that of the dorsal plates. In torsion testing, dorsal plating had the highest peak torque, but there was no significant difference in torsional stiffness between the plate and intramedullary headless compression screw constructs. We concluded that intramedullary headless compression screw fixation is biomechanically superior to K-wires in cantilever bending and torsion; however, it is less stable than dorsal plating. In our study, the initial stability provided by K-wire fixation was sufficient to cope with expected loads in the early rehabilitation period, whereas dorsal plates and IHCS constructs provided stability far in excess of what is required.
- 1 December 2020
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 45 (12) , 1185.e1-1185.e8
Measurement of Scaphoid Bone Microarchitecture: A Computed Tomography Imaging Study and Implications for Screw Placement
- 1 December 2020
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 45 (12) , 1185.e1-1185.e8
Measurement of Scaphoid Bone Microarchitecture: A Computed Tomography Imaging Study and Implications for Screw Placement
- Top Cited Papers
- 11 December 2019
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 48 (10) , 2552-2562
Factors Associated With an Increased Risk of Recurrence After a First-Time Patellar Dislocation: A Systematic Review and Meta-analysis
Recurrent dislocations after a first-time lateral patellar dislocation may occur in more than 50% of patients and can cause long-term disability. Many factors have been suggested to influence the risk of recurrence. To systematically review and quantitatively synthesize the literature for factors associated with an increased risk of recurrence after a first-time patellar dislocation. Systematic review and meta-analysis of observational studies. A total of 4 electronic databases were searched to identify relevant studies published before February 7, 2019. A quality assessment was performed with the National Heart, Lung, and Bone Institute quality assessment score. Factors assessed for their effect on the recurrence rate were documented, and the rates of recurrence were compared. Pooled dichotomous data were analyzed using random-effects meta-analysis with odds ratios (ORs). A total of 17 studies met the criteria for inclusion. The overall rate of recurrent dislocations after a first-time lateral patellar dislocation was 33.6%. An increased risk of recurrence was reported in patients with a younger age (OR, 2.61; P < .00001), open physes (OR, 2.72; P < .00001), trochlear dysplasia (OR, 4.15; P = .009), an elevated tibial tuberosity–trochlear groove (TT-TG) distance (OR, 2.87; P < .00001), and patella alta (OR, 2.38; P = .004). Sex, patterns of medial patellofemoral ligament injury, and history of contralateral dislocations were not found to be associated with an increased recurrence rate (P≥ .05). In studies that reported on the presence of multiple risk factors, recurrence rates were 7.7% to 13.8% when no risk factors were present but increased to 29.6% to 60.2% when 2 risk factors were present and to 70.4% to 78.5% when 3 risk factors were present. Younger age, open physes, trochlear dysplasia, elevated TT-TG distance, and patella alta were key risk factors for the recurrence of lateral patellar dislocations. Despite being not infrequently cited as risk factors, patient sex and a history of contralateral dislocations were not found to be significant risk factors. The presence of multiple risk factors increased the risk, and the development of predictive instability scores in large patient cohorts using all established risk factors should be a focus of future studies.
- 11 December 2019
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 48 (10) , 2552-2562
Top Cited PapersFactors Associated With an Increased Risk of Recurrence After a First-Time Patellar Dislocation: A Systematic Review and Meta-analysis
Recurrent dislocations after a first-time lateral patellar dislocation may occur in more than 50% of patients and can cause long-term disability. Many factors have been suggested to influence the risk of recurrence. To systematically review and quantitatively synthesize the literature for factors associated with an increased risk of recurrence after a first-time patellar dislocation. Systematic review and meta-analysis of observational studies. A total of 4 electronic databases were searched to identify relevant studies published before February 7, 2019. A quality assessment was performed with the National Heart, Lung, and Bone Institute quality assessment score. Factors assessed for their effect on the recurrence rate were documented, and the rates of recurrence were compared. Pooled dichotomous data were analyzed using random-effects meta-analysis with odds ratios (ORs). A total of 17 studies met the criteria for inclusion. The overall rate of recurrent dislocations after a first-time lateral patellar dislocation was 33.6%. An increased risk of recurrence was reported in patients with a younger age (OR, 2.61; P < .00001), open physes (OR, 2.72; P < .00001), trochlear dysplasia (OR, 4.15; P = .009), an elevated tibial tuberosity–trochlear groove (TT-TG) distance (OR, 2.87; P < .00001), and patella alta (OR, 2.38; P = .004). Sex, patterns of medial patellofemoral ligament injury, and history of contralateral dislocations were not found to be associated with an increased recurrence rate (P≥ .05). In studies that reported on the presence of multiple risk factors, recurrence rates were 7.7% to 13.8% when no risk factors were present but increased to 29.6% to 60.2% when 2 risk factors were present and to 70.4% to 78.5% when 3 risk factors were present. Younger age, open physes, trochlear dysplasia, elevated TT-TG distance, and patella alta were key risk factors for the recurrence of lateral patellar dislocations. Despite being not infrequently cited as risk factors, patient sex and a history of contralateral dislocations were not found to be significant risk factors. The presence of multiple risk factors increased the risk, and the development of predictive instability scores in large patient cohorts using all established risk factors should be a focus of future studies.
- 3 September 2019
- Published by Wiley in Anz Journal of Surgery
- Vol. 89 (10) , 1308-1313
Biomechanical performance of an intramedullary Echidna pin for fixation of comminuted mid‐shaft clavicle fractures
Background Surgical fixation of comminuted mid‐shaft clavicle fractures commonly employs intramedullary devices; however, pins with smooth surfaces are prone to migration, whilst threaded pins can be challenging to remove post‐operatively. The aim of this study was to evaluate the biomechanical performance of fractured clavicles repaired using a novel intramedullary Echidna pin device and a non‐threaded Knowles pin. The Echidna pin features retractable spines that engage with the bone to minimize migration and facilitate ease of device removal. Methods A total of 28 cadaveric clavicle specimens were harvested and a mid‐shaft wedge‐shaped osteotomy was performed to simulate a comminuted butterfly fragment. Specimens were allocated randomly to either the Echidna pin or Knowles pin fracture repair groups. Following surgery, eight specimens in each group underwent 200 cycles of four‐point bending, whilst six specimens in each group underwent torsional testing and pull‐out. Cyclic construct bending stiffness, torsional stiffness and ultimate strength were recorded. Results Echidna pin intramedullary repair constructs showed significantly greater bending stiffness (mean difference 0.55 N.m/°, 95% confidence interval −0.96, −0.14, P = 0.01) and pull‐out strength (mean difference 146.03 N, 95% confidence interval 29.14, 262.92, P = 0.019) in comparison to Knowles pin constructs. There was no significant difference in torsional stiffness between Echidna pin and Knowles pin repair constructs (P > 0.05). Conclusion The intramedullary Echidna pin device, which exhibits greater bending strength and pull‐out strength than that of the Knowles pin, may produce a more stable clavicle fracture reduction compared to that of commercially available threadless intramedullary pins.
- 3 September 2019
- Published by Wiley in Anz Journal of Surgery
- Vol. 89 (10) , 1308-1313
Biomechanical performance of an intramedullary Echidna pin for fixation of comminuted mid‐shaft clavicle fractures
Background Surgical fixation of comminuted mid‐shaft clavicle fractures commonly employs intramedullary devices; however, pins with smooth surfaces are prone to migration, whilst threaded pins can be challenging to remove post‐operatively. The aim of this study was to evaluate the biomechanical performance of fractured clavicles repaired using a novel intramedullary Echidna pin device and a non‐threaded Knowles pin. The Echidna pin features retractable spines that engage with the bone to minimize migration and facilitate ease of device removal. Methods A total of 28 cadaveric clavicle specimens were harvested and a mid‐shaft wedge‐shaped osteotomy was performed to simulate a comminuted butterfly fragment. Specimens were allocated randomly to either the Echidna pin or Knowles pin fracture repair groups. Following surgery, eight specimens in each group underwent 200 cycles of four‐point bending, whilst six specimens in each group underwent torsional testing and pull‐out. Cyclic construct bending stiffness, torsional stiffness and ultimate strength were recorded. Results Echidna pin intramedullary repair constructs showed significantly greater bending stiffness (mean difference 0.55 N.m/°, 95% confidence interval −0.96, −0.14, P = 0.01) and pull‐out strength (mean difference 146.03 N, 95% confidence interval 29.14, 262.92, P = 0.019) in comparison to Knowles pin constructs. There was no significant difference in torsional stiffness between Echidna pin and Knowles pin repair constructs (P > 0.05). Conclusion The intramedullary Echidna pin device, which exhibits greater bending strength and pull‐out strength than that of the Knowles pin, may produce a more stable clavicle fracture reduction compared to that of commercially available threadless intramedullary pins.
- 26 January 2017
- Published by Wiley in Anz Journal of Surgery
- Vol. 87 (6) , 483-487
Load response and gap formation in a single‐row cruciate suture rotator cuff repair
Background: Double‐row rotator cuff tendon repair techniques may provide superior contact area and strength compared with single‐row repairs, but are associated with higher material expenses and prolonged operating time. The purpose of this study was to evaluate gap formation, ultimate tensile strength and stiffness of a single‐row cruciate suture rotator cuff repair construct, and to compare these results with those of the Mason‐Allen and SutureBridge repair constructs.Methods: Infraspinatus tendons from 24 spring lamb shoulders were harvested and allocated to cruciate suture, Mason‐Allen and SutureBridge repair groups. Specimens were loaded cyclically between 10 and 62 N for 200 cycles, and gap formation simultaneously measured using a high‐speed digital camera. Specimens were then loaded in uniaxial tension to failure, and construct stiffness and repair strength were evaluated.Results: Gap formation in the cruciate suture repair was significantly lower than that of the Mason‐Allen repair (mean difference = 0.6 mm, P = 0.009) and no different from that of the SutureBridge repair (P > 0.05). Both the cruciate suture repair (mean difference = 15.7 N/mm, P = 0.002) and SutureBridge repair (mean difference = 15.8 N/mm, P = 0.034) were significantly stiffer than that of the Mason‐Allen repair; however, no significant differences in ultimate tensile strength between repair groups were discerned (P > 0.05).Conclusion: The cruciate suture repair construct, which may represent a simple and cost‐effective alternative to double‐row and double‐row equivalent rotator cuff repairs, has comparable biomechanical strength and integrity with that of the SutureBridge repair, and may result in improved construct longevity and tendon healing compared with the Mason‐Allen repair.
- 26 January 2017
- Published by Wiley in Anz Journal of Surgery
- Vol. 87 (6) , 483-487
Load response and gap formation in a single‐row cruciate suture rotator cuff repair
Background: Double‐row rotator cuff tendon repair techniques may provide superior contact area and strength compared with single‐row repairs, but are associated with higher material expenses and prolonged operating time. The purpose of this study was to evaluate gap formation, ultimate tensile strength and stiffness of a single‐row cruciate suture rotator cuff repair construct, and to compare these results with those of the Mason‐Allen and SutureBridge repair constructs.Methods: Infraspinatus tendons from 24 spring lamb shoulders were harvested and allocated to cruciate suture, Mason‐Allen and SutureBridge repair groups. Specimens were loaded cyclically between 10 and 62 N for 200 cycles, and gap formation simultaneously measured using a high‐speed digital camera. Specimens were then loaded in uniaxial tension to failure, and construct stiffness and repair strength were evaluated.Results: Gap formation in the cruciate suture repair was significantly lower than that of the Mason‐Allen repair (mean difference = 0.6 mm, P = 0.009) and no different from that of the SutureBridge repair (P > 0.05). Both the cruciate suture repair (mean difference = 15.7 N/mm, P = 0.002) and SutureBridge repair (mean difference = 15.8 N/mm, P = 0.034) were significantly stiffer than that of the Mason‐Allen repair; however, no significant differences in ultimate tensile strength between repair groups were discerned (P > 0.05).Conclusion: The cruciate suture repair construct, which may represent a simple and cost‐effective alternative to double‐row and double‐row equivalent rotator cuff repairs, has comparable biomechanical strength and integrity with that of the SutureBridge repair, and may result in improved construct longevity and tendon healing compared with the Mason‐Allen repair.