Flexural Strength, Monomer Release, and Wear of Occlusal Splint Materials Fabricated Through Conventional, Milled, or 3D‐Printed Methods
Open Access
- 26 April 2026
- journal article
- research article
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 12 (2) , e70361
Abstract
Objective: To evaluate the flexural strength, monomer release, and wear resistance between conventional, milled polymethylmethacrylate (PMMA), and 3D‐printed resins built at 90° and 60° printing angles for occlusal splints. Materials and Methods: 60‐rectangular and 100‐disc specimens were fabricated from heat‐cured PMMA (Oracryl [HP], Bracon Dental, United Kingdom), milled PMMA (Kerox Premia [KP], Kerox Dental, Hungary), and 3D‐printed resins (FreePrint Splint2.0 [FS], Detax, Ettlingen, Germany, and KeySplint Hard [KS], Keystone Industries, Myerstown, USA) at 90° and 60° printing angles. Specimens for flexural strength and wear tests were immersed immediately in 37°C water for 50 h and thermally aged for 20,000 cycles. Flexural strength was evaluated using a three‐point bend test. Wear was tested using a chewing simulator for 140,000 cycles, and volume loss was calculated using Autodesk MeshMixer software. Monomer release was analyzed via UV spectrophotometry over 7 days. Statistical analysis was performed using the Shapiro–Wilk test and one‐way ANOVA with Tukey's multiple comparison tests. Results: KP showed the highest mean flexural strength (115.5 ± 5.3 MPa, p < 0.0001), followed by HP (86.6 ± 10.8 MPa, p < 0.0001), with 3D‐printed resin showed the lowest. Meanwhile 90° FS showed greater flexural strength (60.5 ± 3.8 MPa) compared to 60° FS ( p < 0.001) and KS ( p < 0.01). The difference between 90° and 60° KS were not statistically significant ( p > 0.05). Monomer release peaked on Day 3 for all groups, with KS consistently showing the highest concentration (29.7 ± 3.6 ppm), followed by FS (28.8 ± 3.8 ppm), HP (27.9 ± 4.9 ppm), and lastly, KP showed the lowest concentration (24.9 ± 3.8 ppm). KP demonstrated the lowest mean volume loss (2.5 ± 1.3 mm 3 , p < 0.01), followed by HP (4.4 ± 1.7 MPa), whereas 3D‐printed resin showed the highest. No significant wear differences were observed between 90° and 60° printing angles. Conclusion: Milled PMMA outperformed other materials, followed by conventional PMMA, while 3D‐printed resin showed inferior performance in flexural strength, wear resistance, and monomer release. Printing angles significantly influenced flexural strength but not wear properties in 3D‐printed resins.Keywords
This publication has 29 references indexed in Scilit:
- Mechanical and physical properties of splint materials for oral appliances produced by additive, subtractive and conventional manufacturingDental Materials, 2024
- Cytotoxicity of 3D‐printed, milled, and conventional oral splint resins to L929 cells and human gingival fibroblastsClinical and Experimental Dental Research, 2022
- Evaluation of wear behaviour of various occlusal splint materials and manufacturing processesJournal of the Mechanical Behavior of Biomedical Materials, 2022
- A digital method for wear volume loss analysis using a single-scan three-dimensional datasetJournal of Dental Sciences, 2021
- A Literature Review on Chewing Simulation and Wear Mechanisms of Dental BiomaterialsJournal of Bio- and Tribo-Corrosion, 2021
- Elution behavior of a 3D-printed, milled and conventional resin-based occlusal splint materialDental Materials, 2021
- Evaluation of the mechanical properties and degree of conversion of 3D printed splint materialJournal of the Mechanical Behavior of Biomedical Materials, 2021
- Impact of fabrication procedures on residual monomer elution of conventional polymethyl methacrylate (PMMA)—a measurement approach by UV/Vis spectrophotometryClinical Oral Investigations, 2020
- Biocompatibility of polymethylmethacrylate resins used in dentistryJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2012
- Residual monomer content and its release into water from denture base materialsDental Materials, 1995