HPHaralampos Petridis

Haralampos Petridis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Haralampos Petridis has a total of 64 co-authors. Here are the top co-authors by number of shared publications:

  • Hiroshi Hirayama

    3 shared publications
  • Nikolaos M Kafantaris

    3 shared publications
  • Pavlos Garefis

    3 shared publications
  • Anne Margaret Young

    Division of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, London, UK

    2 shared publications
  • Ghada O Alrabeah

    Prosthodontic Unit, Department of Restorative Dentistry, UCL Eastman Dental Institute, University College London, London, UK; Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia,; Division of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, University College London, London, UK

    2 shared publications
  • J. Berry

    Department of Adult Oral Health, Institute of Dentistry, Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London

    2 shared publications

Latest Publications

  • Open Access

    Flexural Strength, Monomer Release, and Wear of Occlusal Splint Materials Fabricated Through Conventional, Milled, or 3D‐Printed Methods

    by Nurul Liyana Aminuddin, Haralampos Petridis

    Objective: To evaluate the flexural strength, monomer release, and wear resistance between conventional, milled polymethylmethacrylate (PMMA), and 3D‐printed resins built at 90° and 60° printing angles for occlusal splints. Materials and Methods: 60‐rectangular and 100‐disc specimens were fabricated from heat‐cured PMMA (Oracryl [HP], Bracon Dental, United Kingdom), milled PMMA (Kerox Premia [KP], Kerox Dental, Hungary), and 3D‐printed resins (FreePrint Splint2.0 [FS], Detax, Ettlingen, Germany, and KeySplint Hard [KS], Keystone Industries, Myerstown, USA) at 90° and 60° printing angles. Specimens for flexural strength and wear tests were immersed immediately in 37°C water for 50 h and thermally aged for 20,000 cycles. Flexural strength was evaluated using a three‐point bend test. Wear was tested using a chewing simulator for 140,000 cycles, and volume loss was calculated using Autodesk MeshMixer software. Monomer release was analyzed via UV spectrophotometry over 7 days. Statistical analysis was performed using the Shapiro–Wilk test and one‐way ANOVA with Tukey's multiple comparison tests. Results: KP showed the highest mean flexural strength (115.5 ± 5.3 MPa, p < 0.0001), followed by HP (86.6 ± 10.8 MPa, p < 0.0001), with 3D‐printed resin showed the lowest. Meanwhile 90° FS showed greater flexural strength (60.5 ± 3.8 MPa) compared to 60° FS ( p < 0.001) and KS ( p < 0.01). The difference between 90° and 60° KS were not statistically significant ( p > 0.05). Monomer release peaked on Day 3 for all groups, with KS consistently showing the highest concentration (29.7 ± 3.6 ppm), followed by FS (28.8 ± 3.8 ppm), HP (27.9 ± 4.9 ppm), and lastly, KP showed the lowest concentration (24.9 ± 3.8 ppm). KP demonstrated the lowest mean volume loss (2.5 ± 1.3 mm 3 , p < 0.01), followed by HP (4.4 ± 1.7 MPa), whereas 3D‐printed resin showed the highest. No significant wear differences were observed between 90° and 60° printing angles. Conclusion: Milled PMMA outperformed other materials, followed by conventional PMMA, while 3D‐printed resin showed inferior performance in flexural strength, wear resistance, and monomer release. Printing angles significantly influenced flexural strength but not wear properties in 3D‐printed resins.


  • Open Access

    Direct restorations versus full crowns in endodontically treated molar teeth: A three-year randomized clinical trial

    by Motasum Abu-Awwad, Ruba Halasa, Laila Haikal, Ahmad El-Ma'AIta, Mohammad Hammad, Haralampos Petridis


  • Open Access

    Comparison of Flexural Strength and Wear of Injectable, Flowable and Paste Composite Resins

    by Hadi Rajabi, Michael Denny, Kostas Karagiannopoulos, Haralampos Petridis

    (1) Objectives: This study investigated and compared the wear and flexural strength of two highly filled (injectable), one flowable and one paste composite. (2) Methods: Two highly filled flowable composites (G-aenial Universal Injectable and Beautifil Plus F00), a paste composite (Empress Direct) and a conventional flowable (Tetric EvoFlow) were tested. A two-body wear test was carried out using 10 disc-shaped samples from each group, which were subjected to 200,000 wear machine cycles to simulate wear, followed by Scanning Electron Microscope analysis. Flexural strength was tested using a three-point bend test using 15 beam samples for each of the four groups. Values were statistically compared using one-way analysis of variance (ANOVA) for flexural strength and a Kruskal–Wallis test for wear. (3) Results: The median volume loss for G-aenial Universal Injectable and Beautifil Plus F00 was statistically lower than that of both Empress Direct and Tetric EvoFlow. For flexural strength the two highly filled flowable composites both exhibited statistically higher mean flexural strength values compared to Empress Direct (p < 0.004) and Tetric Evoflow (p < 0.001). There were no statistically significant differences in the values of wear and flexural strength between the two highly filled flowable composites. (4) Conclusions/significance: Highly filled flowable composite resins with nano filler particles outperformed a conventional flowable and a paste composite resin in terms of wear resistance and flexural strength, and may be suitable to use in occlusal, load-bearing areas.


  • Open Access

    Use of Biosensors within the Oral Environment for Systemic Health Monitoring—A Systematic Review

    by Natalie Archer, Sa’ada Ladan, Henry T. Lancashire, Haralampos Petridis

    Scientific advances in biosensor technology are leading to the potential of wearable biosensors for salivary biomarker detection. This review aims to identify the current status of intraoral biosensor technology that can be used to monitor systemic diseases. A total of 11 studies were identified for inclusion, which included nine different devices, including modified mouthguards, retainers, toothbrushes, and dental floss. Out of the 11 studies, 8 studied continuous biomarker monitoring, and the remaining 3 were point-of-care applications. A total of seven biomarkers were studied, six of which investigated the intraoral detection of salivary glucose levels using glucose oxidase enzyme. All the sensors demonstrated excellent sensitivity (minimum R = 0.9928) and selectivity. The study designs were proof of concept, with five studies including in vivo components. We concluded that while there are established links between salivary biomarkers and systemic health, there is a lack of mature intraoral biosensor research. Refinement of biosensor design and data analysis is required to improve patient acceptability by promoting more discrete, real-time, low-cost, and wireless devices. Further research that utilises the biosensor technology in large controlled clinical trials will be required to confirm clinical applicability before intraoral biosensor technology can be integrated into routine health monitoring.


  • Open Access

    Comparisons of analog and digital methods to produce an accurate trial restoration

    by Yun-Shan Koh, Noland Naidoo, Haralampos Petridis


  • Open Access

    Effects of Novel Dental Composites on Streptococcus mutans Biofilms

    by Rayan B. Yaghmoor, Mohammad Abdel-Hadi, Haralampos Petridis, Elaine Allan, Anne M. Young

    With the phase-out of amalgam and the increase in minimally invasive dentistry, there is a growing need for high-strength composite materials that can kill residual bacteria and promote tooth remineralization. This study quantifies how antibacterial polylysine (PLS) and re-mineralizing monocalcium phosphate monohydrate (MCPM) affect Streptococcus mutans biofilms and the strength of dental composites. For antibacterial studies, the MCPM-PLS filler percentages were 0-0, 8-4, 12-6, and 16-8 wt% of the composite filler phase. Composite discs were immersed in 0.1% sucrose-supplemented broth containing Streptococcus mutans (UA159) and incubated in an anaerobic chamber for 48 h. Surface biomass was determined by crystal violet (CV) staining. Growth medium pH was measured at 24 and 48 h. Biofilm bacterial viability (CFU), exo-polysaccharide (water-soluble glucan (WSG) and water-insoluble glucan (WIG)), and extracellular DNA (eDNA) were quantified. This was by serial dilution plate counting, phenol-sulfuric acid microassay, and fluorometry, respectively. The biaxial flexural strengths were determined after water immersion for 1 week, 1 month, and 1 year. The MCPM-PLS wt% were 8-4, 8-8, 16-4 and 16-8. The normalized biomass, WSG, and WIG showed a linear decline of 66%, 64%, and 55%, respectively, as the PLS level increased up to 8%. The surrounding media pH (4.6) was all similar. A decrease in bacterial numbers with the 12-6 formula and a significant reduction with 16-8 compared to the 0-0 formulation was observed. The eDNA concentrations in biofilms formed on 12-6 and 16-8 formulations were significantly less than the 0-0 control and 8-4 formulations. Doubling MCPM and PLS caused a 14 and 19% reduction in strength in 1 week, respectively. Average results were lower at 1 month and 1 year but affected less upon doubling MCPM and PLS levels. Moreover, a 4% PLS may help to reduce total biomass and glucan levels in biofilms on the above composites. Higher levels are required to reduce eDNA and provide bactericidal action, but these can decrease early strength.


  • Open Access

    Surface Corrosion from Implant–Abutment Couplings with Different Connection Designs Influences Osteoblasts’ Function: A Novel Technique

    by Ghada Alrabeah, Jonathan C. Knowles, Haralampos Petridis

    The improved peri-implant bone response demonstrated when utilizing the platform-switching concept may result from the reduced levels of metal ions released from implant–abutment surfaces to the surrounding tissues. These corrosion products may play a major role in crestal bone remodeling around dental implants. This study evaluated the effect of different implant–abutment couplings (platform-matched vs. platform-switched) on osteoblasts’ function. Titanium alloy and cobalt–chrome alloy abutments were coupled with titanium cylinders, forming either platform-switched or platform-matched groups, and were incubated in human osteoblast cultures utilizing a novel direct-exposure technique. Viability was evaluated over 21 days using Alamar Blue assay. Apoptosis was measured after 24 h using flow cytometry. The expression of genes related to bone resorption was analysed over 21 days using a real-time quantitative polymerase chain reaction assay. Cell viability was reduced from day 4 to day 21 (p < 0.05), with higher rates of early apoptosis (p < 0.05) compared to the controls. Apoptosis was higher in the platform-matched groups (p < 0.05). The tested genes’ expression was up-regulated after 1 and 3 days of exposure to implant–abutment couplings (p < 0.05). The upregulation was more pronounced in platform-matched groups (p < 0.05). Exposure of osteoblasts to implant–abutment couplings induced adverse biological responses, which were more pronounced with platform-matched couplings. These reactions might be related to the increased amounts of metal ions released from the platform-matched couplings, highlighting the possible role of corrosion products in the mediation of crestal bone loss around dental implants.

  • Open Access

    Biomarkers associated with periodontitis and peri-implantitis: a systematic review

    by Amardip Singh Kalsi, Federico Moreno, Haralampos Petridis

    Kalsi AS, et al. J Periodontal Implant Sci. 2019 Nov;50:e39. https://doi.org/10.5051/jpis.1902840142


  • Open Access

    Polymerization Kinetics Stability, Volumetric Changes, Apatite Precipitation, Strontium Release and Fatigue of Novel Bone Composites for Vertebroplasty

    by Piyaphong Panpisut, Kirsty Main, Muhammad Adnan Khan, Mayda Arshad, Wendy Xia, Haralampos Petridis, Anne Margaret Young

    Purpose: The aim was to determine effects of diluent monomer and monocalcium phosphate monohydrate (MCPM) on polymerization kinetics and volumetric stability, apatite precipitation, strontium release and fatigue of novel dual-paste composites for vertebroplasty. Materials and methods: Polypropylene (PPGDMA) or triethylene (TEGDMA) glycol dimethacrylates (25 wt%) diluents were combined with urethane dimethacrylate (70 wt%) and hydroxyethyl methacrylate (5 wt%). 70 wt% filler containing glass particles, glass fibers (20 wt%) and polylysine (5 wt%) was added. Benzoyl peroxide and MCPM (10 or 20 wt%) or N-tolyglycine glycidyl methacrylate and tristrontium phosphate (15 wt%) were included to give initiator or activator pastes. Commercial PMMA (Simplex) and bone composite (Cortoss) were used for comparison. ATR-FTIR was used to determine thermal activated polymerization kinetics of initiator pastes at 50-80 °C. Paste stability, following storage at 4-37 °C, was assessed visually or through mixed paste polymerization kinetics at 25 °C. Polymerization shrinkage and heat generation were calculated from final monomer conversions. Subsequent expansion and surface apatite precipitation in simulated body fluid (SBF) were assessed gravimetrically and via SEM. Strontium release into water was assessed using ICP-MS. Biaxial flexural strength (BFS) and fatigue properties were determined at 37 °C after 4 weeks in SBF. Results: Polymerization profiles all exhibited an inhibition time before polymerization as predicted by free radical polymerization mechanisms. Initiator paste inhibition times and maximum reaction rates were described well by Arrhenius plots. Plot extrapolation, however, underestimated lower temperature paste stability. Replacement of TEGDMA by PPGDMA, enhanced paste stability, final monomer conversion, water-sorption induced expansion and strontium release but reduced polymerisation shrinkage and heat generation. Increasing MCPM level enhanced volume expansion, surface apatite precipitation and strontium release. Although the experimental composite flexural strengths were lower compared to those of commercially available Simplex, the extrapolated low load fatigue lives of all materials were comparable. Conclusions: Increased inhibition times at high temperature give longer predicted shelf-life whilst stability of mixed paste inhibition times is important for consistent clinical application. Increased volumetric stability, strontium release and apatite formation should encourage bone integration. Replacing TEGDMA by PPGDMA and increasing MCPM could therefore increase suitability of the above novel bone composites for vertebroplasty. Long fatigue lives of the composites may also ensure long-term durability of the materials.

  • Reduction of Tribocorrosion Products When Using the Platform-Switching Concept

    by G.O. Alrabeah, J.C. Knowles, H. Petridis

    The reduced marginal bone loss observed when using the platform-switching concept may be the result of reduced amounts of tribocorrosion products released to the peri-implant tissues. Therefore, the purpose of this study was to compare the tribocorrosion product release from various platform-matched and platform-switched implant-abutment couplings under cyclic loading. Forty-eight titanium implants were coupled with pure titanium, gold alloy, cobalt-chrome alloy, and zirconia abutments forming either platform-switched or platform-matched groups ( n = 6). The specimens were subjected to cyclic occlusal forces in a wet acidic environment for 24 h followed by static aqueous immersion for 6 d. The amount of metal ions released was measured using inductively coupled plasma mass spectrometry. Microscopic evaluations were performed pre- and postimmersion under scanning electron microscope (SEM) equipped with energy-dispersive spectroscopy X-ray for corrosion assessment at the interface and wear particle characterization. All platform-switched groups showed less metal ion release compared with their platform-matched counterparts within each abutment material group ( P < 0.001). Implants connected to platform-matched cobalt-chrome abutments demonstrated the highest total mean metal ion release (218 ppb), while the least total mean ion release (11 ppb) was observed in the implants connected to platform-switched titanium abutments ( P ≤ 0.001). Titanium was released from all test groups, with its highest mean release (108 ppb) observed in the implants connected to platform-matched gold abutments ( P < 0.001). SEM images showed surface tribocorrosion features such as pitting and bands of fretting scars. Wear particles were mostly titanium, ranging from submicron to 48 µm in length. The platform-matched groups demonstrated a higher amount of metal ion release and more surface damage. These findings highlight the positive effect of the platform-switching concept in the reduction of tribocorrosion products released from dental implants, which consequently may minimize the adverse tissue reactions that lead to peri-implant bone loss.