Leadless Pacing of the Heart Using Induction Technology: A Feasibility Study
- 23 January 2009
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 32 (2) , 177-183
Abstract
Objectives: To develop a leadless pacemaker system based on induction technology and to investigate its feasibility and safety in the pig model. Background: Despite tremendous technical advances during the last decades, cardiac pacing is still associated with a considerable rate of complications that can be primarily attributed to the leads. Methods: The device consists of a transmitter unit implanted subcutaneously just above the heart and an endocardial receiver unit implanted in the apex of the right ventricle. The transmitter unit generates an alternating magnetic field that is converted into a voltage pulse by the receiver unit. In order to test feasibility, the receiver unit was attached to an electrophysiology catheter for signal recording and placed in the apex of the right ventricle of a pig. Subsequently, the receiver unit was implanted without external connection in the right ventricle. Results: An alternating magnetic field of about 0.5 mT was generated by the transmitter unit in a distance of 3 cm. Voltage pulses with a duration of 0.4 ms and voltage amplitude of 0.6–1.0 V were generated. Using these pulse characteristics, a reliable stimulation of the heart could be achieved. A secure fixation of the receiver unit in the apex of the right ventricle could be obtained for the duration of this short‐term study by using screw fixation. Conclusions: This study shows that induction technology is feasible for cardiac pacing. Typical voltage pulses could be generated by which an effectively stimulation in vivo could be achieved.Keywords
This publication has 13 references indexed in Scilit:
- First Human Demonstration of Cardiac Stimulation With Transcutaneous Ultrasound Energy DeliveryJACC, 2007
- Right Ventricular Pacing Can Induce Ventricular Dyssynchrony in Patients With Atrial Fibrillation After Atrioventricular Node AblationJACC, 2006
- Feasibility and safety of a novel technology for pacing without leadsHeart Rhythm, 2006
- Dilated Cardiomyopathy Following Right Ventricular Pacing for AV Block in Young Patients: Resolution After Upgrading to Biventricular Pacing SystemsJournal of Cardiovascular Electrophysiology, 2006
- Cardiac pacing: the state of the artThe Lancet, 2004
- Impact of Coronary Sinus Lead Position on Biventricular Pacing:Journal of Cardiovascular Electrophysiology, 2004
- Left ventricular septal and apex pacing for optimal pump function in canine heartsJACC, 2003
- Transvenous Defibrillation Leads: High Incidence of Failure During Long‐Term Follow‐UpJournal of Cardiovascular Electrophysiology, 2003
- Permanent Epicardial Pacing in Pediatric PatientsCirculation, 2001
- Updated Appraisal of Pacing Lead Performance from the Danish Pacemaker Register: The Reliability of Bipolar Pacing Leads Has ImprovedPacing and Clinical Electrophysiology, 2000