Design and Development of a Miniaturized Percutaneously Deployable Wireless Left Ventricular Assist Device: Early Prototypes and Feasibility Testing
Authors:
- 1 March 2018
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 64 (2) , 147-153
Abstract
The current left ventricular assist devices (LVADs) are limited by a highly invasive implantation procedure in a severely unstable group of advanced heart failure patients. Additionally, the current transcutaneous power drive line acts as a nidus for infection resulting in significant morbidity and mortality. In an effort to decrease this invasiveness and eliminate drive line complications, we have conceived a wireless miniaturized percutaneous LVAD, capable of being delivered endovascularly with a tether-free operation. The system obviates the need for a transcutaneous fluid purge line required in existing temporary devices by utilizing an incorporated magnetically coupled impeller for a complete seal. The objective of this article was to demonstrate early development and proof-of-concept feasibility testing to serve as the groundwork for future formalized device development. Five early prototypes were designed and constructed to iteratively minimize the pump size and improve fluid dynamic performance. Various magnetic coupling configurations were tested. Using SolidWorks and ANSYS software for modeling and simulation, several geometric parameters were varied. HQ curves were constructed from preliminary in vitro testing to characterize the pump performance. Bench top tests showed no-slip magnetic coupling of the impeller to the driveshaft up to the current limit of the motor. The pump power requirements were tested in vitro and were within the appropriate range for powering via a wireless energy transfer system. Our results demonstrate the proof-of-concept feasibility of a novel endovascular cardiac assist device with the potential to eventually offer patients an untethered, minimally invasive support.Keywords
This publication has 16 references indexed in Scilit:
- National Trends in the Utilization of Short-Term Mechanical Circulatory SupportJACC, 2014
- Sixth INTERMACS annual report: A 10,000-patient databaseThe Journal of Heart and Lung Transplantation, 2014
- Energy Transmission and Power Sources for Mechanical Circulatory Support Devices to Achieve Total ImplantabilityThe Annals of Thoracic Surgery, 2014
- Innovative Free-Range Resonant Electrical Energy Delivery System (FREE-D System) for a Ventricular Assist Device Using Wireless PowerASAIO Journal, 2014
- Toward Total Implantability Using Free-Range Resonant Electrical Energy Delivery System: Achieving Untethered Ventricular Assist Device Operation Over Large DistancesCardiology Clinics, 2011
- 4 National Trends in Readmission(REA) Rates Following Left Ventricular Assist Device (LVAD) TherapyThe Journal of Heart and Lung Transplantation, 2011
- Percutaneous left ventricular assist in ischemic cardiac arrestCritical Care Medicine, 2009
- The diameter of the common femoral artery in healthy human: Influence of sex, age, and body sizeJournal of Vascular Surgery, 1999
- Effect of the hemopump left ventricular assist device on regional myocardial perfusion and function. Reduction of ischemia during coronary occlusion.1989
- Prevention of postischemic cardiac injury by the orally active iron chelator 1,2-dimethyl-3-hydroxy-4-pyridone (L1) and the antioxidant (+)-cyanidanol-3.Circulation, 1989