Impact of Working Fluids and Performance of Isobutane in the Refrigeration System
Authors:
- Solomon O. BanjoSBSolomon O. Banjo
- Bukola O. BolajiBBBukola O. Bolaji
- Oluseyi O. AjayiOAOluseyi O. Ajayi
- Olatunde A. OyelaranOOOlatunde A. Oyelaran
Open Access
- 16 September 2021
- book chapter
- Published by IntechOpen
Abstract
The effect of heat transfer medium (HTM) on the environment is associated with ozone layer depletion and global warming. The role of HTM (working fluid) in the heating and air conditioning industries is paramount, which cannot be underestimated. The conventional refrigerant has been predominantly used over decades due to their thermodynamic properties. However, hydrocarbon refrigerants such as isobutane are considered substitutes because they have negligible global warming potential and zero ozone depletion. That makes it eco-friendly among other existing refrigerants. The investigation of the refrigeration system’s performance characteristics required consideration for the coefficient of performance, refrigerating effect, and the compressor work; this enables the determination of the system’s efficiency without any assumption. Another factor that suggests a better absorption of refrigerant (working fluid) into a refrigeration system is an increase in the coefficient of performance (COP). The effect will cause a reduction in the rate of energy consumption by the compressor. The result shows that the system’s coefficient of performance when using R600a was 27.1% higher than when working with R134a, with an energy reduction of 23.3%.Keywords
This publication has 39 references indexed in Scilit:
- Raw Gas Transmission2012
- Experimental study of R152a and R32 to replace R134a in a domestic refrigeratorEnergy, 2010
- Vapour condensation of R22 retrofit substitutes R417A, R422A and R422D on CuNi turbo C tubesInternational Journal of Refrigeration, 2010
- HFC134a/HC600a/HC290 mixture a retrofit for CFC12 systemsInternational Journal of Refrigeration, 2005
- Environmental implications of hydrocarbon refrigerants applied to the hermetic compressorMaterials & Design (1980-2015), 2005
- Experimental study of hydrocarbon mixtures to replace HFC-134a in a domestic refrigeratorEnergy Conversion and Management, 2005
- Assessment of LPG as a possible alternative to R-12 in domestic refrigeratorsEnergy Conversion and Management, 2003
- Experimental study of new refrigerant mixtures to replace R12 in domestic refrigeratorsApplied Thermal Engineering, 2002
- Refrigeration and the environment — issues and strategies for the futureInternational Journal of Refrigeration, 2002
- Thermodynamic behaviour of an air-conditioning system employing combined evaporative-water and air coolersApplied Energy, 2001