Olanrewaju Solomon Banjo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Olanrewaju Solomon Banjo has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Bukola Olalekan Bolaji
Mechanical Engineering Department, Federal University, Oye-Ekiti, Nigeria
3 shared publications A.S. Afolalu
Department of Mechanical and Mechatronics Engineering, Afe Babalola University, Ado-Ekiti, Nigeria
1 shared publication- Anthony Ogochukwu Onokwai
Department of Mechanical and Mechatronics Engineering, Tshwane University of Technology, Pretoria 0183, South Africa
1 shared publication Babalola P. Olufemi
Mechanical Engineering Department, Covenant University, P.M.B. 1023, Ota, Nigeria
1 shared publicationBukola O. Bolaji
1 shared publicationE.Y. Salawu
Department of Mechanical Engineering, Covenant University, P.M.B. 1023, Ota, Nigeria
1 shared publication
Latest Publications
- Open Access
- 24 September 2026
- Published by University Library in Kragujevac in Applied Engineering Letters : Journal of Engineering and Applied Sciences
- Vol. 11 (3) , 143
Energy Performance Evaluation of a Refrigeration System under Synthesized Biodegradable Material Enhancement
This study investigates the impact of optimizing refrigeration systems using an environmentally friendly refrigerant, isobutane (R600a), which has a low global warming potential (GWP) and zero ozone depletion potential (ODP), coupled with bio-nanofluid. The utilization of this natural refrigerant, combined with a bio-nanofluid developed from agricultural produce, introduces the innovative concept of this study and has the potential to enhance the global market. The incorporation of synthesized biodegradable waste significantly enhances the performance characteristics, including the coefficient of performance (COP), reduced compressor energy consumption, and improved refrigerating effect (RE). Bio-nanoparticles from mango peels (MP) and mango leaves (ML) were extracted using aluminium sulphate (Al₂(SO₄)₃) as the inorganic salt, and experimental examination was achieved with 0.1, 0.5, and 1.0% volume concentrations of the bio-nanofluid. The vapour compression refrigeration system (VCRS) performance was evaluated under an ambient temperature value of 26 °C. The results indicate that the system’s performance operating with a 0.5% volume concentration of aluminium oxide (Al₂O₃) nanoparticles from MP improved significantly compared to the base fluid, with 62% COP enhancement and 17.6% reduction in energy consumption. The lowest evaporator temperature of -23 °C was attained in 120 min.
- 24 September 2026
- Published by University Library in Kragujevac in Applied Engineering Letters : Journal of Engineering and Applied Sciences
- Vol. 11 (3) , 143
Open AccessEnergy Performance Evaluation of a Refrigeration System under Synthesized Biodegradable Material Enhancement
This study investigates the impact of optimizing refrigeration systems using an environmentally friendly refrigerant, isobutane (R600a), which has a low global warming potential (GWP) and zero ozone depletion potential (ODP), coupled with bio-nanofluid. The utilization of this natural refrigerant, combined with a bio-nanofluid developed from agricultural produce, introduces the innovative concept of this study and has the potential to enhance the global market. The incorporation of synthesized biodegradable waste significantly enhances the performance characteristics, including the coefficient of performance (COP), reduced compressor energy consumption, and improved refrigerating effect (RE). Bio-nanoparticles from mango peels (MP) and mango leaves (ML) were extracted using aluminium sulphate (Al₂(SO₄)₃) as the inorganic salt, and experimental examination was achieved with 0.1, 0.5, and 1.0% volume concentrations of the bio-nanofluid. The vapour compression refrigeration system (VCRS) performance was evaluated under an ambient temperature value of 26 °C. The results indicate that the system’s performance operating with a 0.5% volume concentration of aluminium oxide (Al₂O₃) nanoparticles from MP improved significantly compared to the base fluid, with 62% COP enhancement and 17.6% reduction in energy consumption. The lowest evaporator temperature of -23 °C was attained in 120 min.
- 4 May 2022
- Published by Springer Nature
- p. 223-236
Overview of Nano-agro-composite Additives for Wastewater and Effluent Treatment
- 4 May 2022
- Published by Springer Nature
- p. 223-236
Overview of Nano-agro-composite Additives for Wastewater and Effluent Treatment
- Open Access
- 16 September 2021
- Published by IntechOpen
Impact of Working Fluids and Performance of Isobutane in the Refrigeration System
The effect of heat transfer medium (HTM) on the environment is associated with ozone layer depletion and global warming. The role of HTM (working fluid) in the heating and air conditioning industries is paramount, which cannot be underestimated. The conventional refrigerant has been predominantly used over decades due to their thermodynamic properties. However, hydrocarbon refrigerants such as isobutane are considered substitutes because they have negligible global warming potential and zero ozone depletion. That makes it eco-friendly among other existing refrigerants. The investigation of the refrigeration system’s performance characteristics required consideration for the coefficient of performance, refrigerating effect, and the compressor work; this enables the determination of the system’s efficiency without any assumption. Another factor that suggests a better absorption of refrigerant (working fluid) into a refrigeration system is an increase in the coefficient of performance (COP). The effect will cause a reduction in the rate of energy consumption by the compressor. The result shows that the system’s coefficient of performance when using R600a was 27.1% higher than when working with R134a, with an energy reduction of 23.3%.
- 16 September 2021
- Published by IntechOpen
Open AccessImpact of Working Fluids and Performance of Isobutane in the Refrigeration System
The effect of heat transfer medium (HTM) on the environment is associated with ozone layer depletion and global warming. The role of HTM (working fluid) in the heating and air conditioning industries is paramount, which cannot be underestimated. The conventional refrigerant has been predominantly used over decades due to their thermodynamic properties. However, hydrocarbon refrigerants such as isobutane are considered substitutes because they have negligible global warming potential and zero ozone depletion. That makes it eco-friendly among other existing refrigerants. The investigation of the refrigeration system’s performance characteristics required consideration for the coefficient of performance, refrigerating effect, and the compressor work; this enables the determination of the system’s efficiency without any assumption. Another factor that suggests a better absorption of refrigerant (working fluid) into a refrigeration system is an increase in the coefficient of performance (COP). The effect will cause a reduction in the rate of energy consumption by the compressor. The result shows that the system’s coefficient of performance when using R600a was 27.1% higher than when working with R134a, with an energy reduction of 23.3%.
- Open Access
- 1 December 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1378 (4) , 042033
Experimental analysis of the performance characteristic of an eco-friendly HC600a as a retrofitting refrigerant in a thermal system
The negative influence of refrigerants on the climate and the immediate environment in terms of their higher global warming potential (GWP) and ozone depletion potential (ODP) has prompted this study. Currently, natural refrigerants are the preferred alternative refrigerants and hydrocarbon is numbered among these natural refrigerants with zero ODP and negligible GWP. In order to improve and enhance the performance of the refrigeration system, the performance characteristics of the system were investigated experimentally using eco-friendly refrigerant HC600a as alternative to HFC134a. In addition, comparisons were made using refrigerant mass charge of 46 g of isobutane (HC600a) and 70 g of conventional refrigerant (HFC134a). Thermodynamic parametric analysis was conducted using electric power consumption, coefficient of performance (COP), cooling load and pull-down time (PDT) for the used mass charges. REFPROP software was applied to capture the thermodynamic properties of the vapour compression system (VCS). The results showed that the COP increased by 32.2 % when using 46g charge of hydrocarbon refrigerant with energy reduction of 4.5 %. Furthermore, the vapour compression system while using 46 g of isobutane (HC600a) attained an evaporating temperature of -21 °C in 60 minutes while 70 g of HFC134a attained the same temperature in 2 hours 15 minutes, which makes HC600a alternative refrigerant to run in the traditional refrigerator.
- 1 December 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1378 (4) , 042033
Open AccessExperimental analysis of the performance characteristic of an eco-friendly HC600a as a retrofitting refrigerant in a thermal system
The negative influence of refrigerants on the climate and the immediate environment in terms of their higher global warming potential (GWP) and ozone depletion potential (ODP) has prompted this study. Currently, natural refrigerants are the preferred alternative refrigerants and hydrocarbon is numbered among these natural refrigerants with zero ODP and negligible GWP. In order to improve and enhance the performance of the refrigeration system, the performance characteristics of the system were investigated experimentally using eco-friendly refrigerant HC600a as alternative to HFC134a. In addition, comparisons were made using refrigerant mass charge of 46 g of isobutane (HC600a) and 70 g of conventional refrigerant (HFC134a). Thermodynamic parametric analysis was conducted using electric power consumption, coefficient of performance (COP), cooling load and pull-down time (PDT) for the used mass charges. REFPROP software was applied to capture the thermodynamic properties of the vapour compression system (VCS). The results showed that the COP increased by 32.2 % when using 46g charge of hydrocarbon refrigerant with energy reduction of 4.5 %. Furthermore, the vapour compression system while using 46 g of isobutane (HC600a) attained an evaporating temperature of -21 °C in 60 minutes while 70 g of HFC134a attained the same temperature in 2 hours 15 minutes, which makes HC600a alternative refrigerant to run in the traditional refrigerator.
- Open Access
- 1 September 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 331 (1) , 012025
Performance enhancement using appropriate mass charge of R600a in a developed domestic refrigerator
This paper presents performance analysis of a domestic refrigeration system using R600a as refrigerant. Investigation was conducted experimentally to select an appropriate refrigerant mass charge for the system and to compute the cooling system performance characteristics under ambient temperature of 29°C. The choice of the hydrocarbon refrigerant (R600a) became so imperative due to notable influence of chlorofluorocarbons (CFCs), hydrochlorofluorocarbons (HCFCs) and hydrofluorocarbons (HFCs) on global warming and ozone depletion. UNFCCC and Montreal Protocol regulation have banned the use of halogenated refrigerants in cooling and heating systems. The paper reveals that the power consumed by the system using mass charge of 15 g refrigerant was reduced by 9.3 and 10.9% compared with the 10 and 25 g refrigerant mass charges respectively. In addition, the results show that the coefficient of performance (COP) of the refrigeration system while working with 15 g is 24.7 and 20.2% higher than when the system worked with 10 and 25 g refrigerants mass charge respectively. More so, the system attained an evaporator air temperature of -12 °C in 2 hours, which makes 15 g charge refrigerant appropriate for the running of the developed system that has a volume capacity of 68 liters.
- 1 September 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 331 (1) , 012025
Open AccessPerformance enhancement using appropriate mass charge of R600a in a developed domestic refrigerator
This paper presents performance analysis of a domestic refrigeration system using R600a as refrigerant. Investigation was conducted experimentally to select an appropriate refrigerant mass charge for the system and to compute the cooling system performance characteristics under ambient temperature of 29°C. The choice of the hydrocarbon refrigerant (R600a) became so imperative due to notable influence of chlorofluorocarbons (CFCs), hydrochlorofluorocarbons (HCFCs) and hydrofluorocarbons (HFCs) on global warming and ozone depletion. UNFCCC and Montreal Protocol regulation have banned the use of halogenated refrigerants in cooling and heating systems. The paper reveals that the power consumed by the system using mass charge of 15 g refrigerant was reduced by 9.3 and 10.9% compared with the 10 and 25 g refrigerant mass charges respectively. In addition, the results show that the coefficient of performance (COP) of the refrigeration system while working with 15 g is 24.7 and 20.2% higher than when the system worked with 10 and 25 g refrigerants mass charge respectively. More so, the system attained an evaporator air temperature of -12 °C in 2 hours, which makes 15 g charge refrigerant appropriate for the running of the developed system that has a volume capacity of 68 liters.