Tripolar-cuff deviation from ideal model: Assessment by bioelectric field simulations and saline-bath experiments
Authors:
- Iasonas F. TriantisITIasonas F. Triantis
- Andreas DemosthenousADAndreas Demosthenous
- 6 August 2007
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 30 (5) , 550-562
Abstract
Ideally, interference in neural measurements due to signals from nearby muscles can be completely eliminated with the use of tripolar cuffs, in combination with appropriate amplifier configurations, such as the quasi-tripole (QT) and the true-tripole (TT). The operation of these amplifiers, is based on the theoretical property of the nerve cuff to produce a linear relationship of potential versus distance along its length, internally, when external potentials appear between its ends. Thus, in principle, electroneurogram (ENG) recordings from an ideal tripolar cuff would be free from electromyogram (EMG) interference generated by nearby muscles. However, in practice the cuff exhibits non-ideal behaviour leading to "cuff imbalance". The main focus of this paper is to investigate the causes of cuff imbalance, to demonstrate that it should be incorporated as a main parameter in the theoretical ENG-recording cuff electrode model. In addition to cuff asymmetry and tissue growth, the proximity of the interference source to the cuff is shown to result in cuff imbalance. The influence of proximity imbalance on the performance of the QT and TT amplifiers is also considered. Proximity imbalance is studied using bioelectric field simulations and saline-bath experiments. Variation is observed with both distance (40 mm and 70 mm was examined) and orientation (0-180 degrees), with the latter causing a more severe effect especially when the source dipole and the cuff are vertical to each other. The simulations and measurements are in close agreement. Tissue growth imbalance and asymmetry imbalance are also investigated in vitro. Finally, the signal-to-interference ratio (SIR; ENG/EMG) of the QT and TT amplifiers is examined in the presence of cuff imbalance. It is shown that proximity imbalance results in their SIR to peak only at certain cuff orientation values. This important finding offers an insight as to why in practice ENG recordings using these amplifiers have been widely reported to be degraded by EMG interference.Keywords
This publication has 26 references indexed in Scilit:
- An adaptive ENG amplifier for tripolar cuff electrodesIEEE Journal of Solid-State Circuits, 2005
- Implementation of natural sensory feedback in a portable control system for a hand grasp neuroprosthesisMedical Engineering & Physics, 2004
- Skin contact forces extracted from human nerve signals-a possible feedback signal for FES-aided control of standingIEEE Transactions on Biomedical Engineering, 2003
- Biopotentials as command and feedback signals in functional electrical stimulation systemsMedical Engineering & Physics, 2002
- Real Time Foot Drop Correction using Machine Learning and Natural SensorsNeuromodulation: Technology at the Neural Interface, 2002
- An improved configuration for the reduction of EMG in electrode cuff recordings: a theoretical approachIEEE Transactions on Biomedical Engineering, 2000
- Control of FES thumb force using slip information obtained from the cutaneous electroneurogram in quadriplegic manIEEE Transactions on Rehabilitation Engineering, 1999
- Cuff electrodes for long-term recording of natural sensory informationIEEE Engineering in Medicine and Biology Magazine, 1999
- Instrumentation for ENG and EMG recordings in FES systemsIEEE Transactions on Biomedical Engineering, 1994
- Sensory nerve recording for closed-loop control to restore motor functionsIEEE Transactions on Biomedical Engineering, 1993