Abstract
Pressuremeters are designed to simulate the expansion of an infinitely long cylindrical cavity. Tricells have inflatable guard cells to ensure that the central section expands as a cylinder; the lengths of monocells means that the end restriction has little effect on the assumption of a cylindrical expansion. The control and monitoring systems depend on whether changes in volume or displacement are measured; the test is stress- or strain-controlled; the monitoring and control systems are downhole or at the surface; oil, gas or water are used to expand the membrane; and the method to record the data. Examples of commercially available pressuremeters are used to highlight the differences between the probes. Prebored pressuremeters can be used in any ground condition. Self-boring pressuremeters were developed for soils, though they can be used in weak rocks if sufficiently robust. Pushed-in pressuremeters are used in soils.