BCBarry G. Clarke

Barry G. Clarke

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Barry G. Clarke has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Electrical conductivity of sand–clay mixtures

    by Muataz M. Al-Moadhen, Barry G. Clarke, Xiaohui Chen

    This paper presents the results of the electrical conductivity measurements of sand–clay mixtures that were formed of three types of sands and five pure clays and prepared with water of low salinity. The results show that an increase in clay content results in an increase in the overall electrical conductivity. Moreover, a direct or inverse relationship between the overall soil electrical conductivity (σ T) and porosity (n) is observed depending on whether the water conductivity (σw) is higher or lower than the clay particle surface conductivity (σ s). Common predictive models for electrical conductivity were developed for sands and clayey sands with a clay content of less than 20%. This research extended these studies to include clays, sandy clays and clayey sands to show that it is possible to predict the electrical conductivity of a soil from its composition and fabric.


  • Introduction

    by B.G. Clarke

    A pressuremeter is a cylindrical probe with an expandable flexible membrane designed to apply a uniform pressure to the walls of a borehole. A form of pressuremeter can be installed in any ground condition ranging from soft organic clays to hard rocks. The parameters obtained from a pressuremeter test are a function of the probe, the method of installation, the method of testing and the chosen method of analysis and interpretation. Improvements in equipment, data monitoring, analysis and interpretation have created a robust system that provides a basis for consistency in the operation of pressuremeters to produce either intrinsic ground properties or design parameters. Manufacturers’ guidelines and international standards are available. It is important to understand the differences in type of pressuremeters, the site operations and the limitations of the methods of interpretation. This book covers the equipment, the site operations including test procedures, the theory of cavity expansion, methods of interpreting tests and the application of the results in design.

  • Analysis of expanding cavities

    by B.G. Clarke

    A brief description of the simple theories of cavity expansion, which can be used to interpret pressuremeter tests, are used to show the assumptions made and the limitations of the methods. Analytical methods of the loading and unloading curves include linear and non-linear elastic, perfectly plastic, strain-hardening and strain-softening incompressible and dilatant materials. Most of the analyses assume the material to be a continuum, but in many practical cases the ground either contains discontinuities or discontinuities are created during a test. Pressuremeter tests undertaken as part of routine investigations are interpreted using empirical rules or linear and non-linear elastic and perfectly plastic models. More complex constitutive models in association with numerical methods are used to study expanding cavities and determine the sensitivity of the expansion to the probe geometry, the installation method, the test procedure, the ground response and the characteristics of the ground.

  • Design rules and applications

    by B.G. Clarke

    A form of pressuremeter can be used in all ground conditions, and ground properties are obtained either directly, theoretically or empirically from a pressuremeter test. The results of pressuremeter tests are used to produce design properties directly, to determine intrinsic properties by applying constitutive models to interpret the data, to validate more complex constitutive models used in numerical methods and as a means of control in ground-improvement schemes. Bearing resistance and settlements of shallow and deep foundations can be predicted with a degree of confidence using the Ménard pressuremeter. Ground properties including total horizontal stress, stiffness and total and effective strength parameters from pressuremeter tests are used to create site-specific empirical correlations, validate constitutive models, and produce profiles of mechanical properties to be used in design. The pressuremeter is used in conjunction with other tests to produce comprehensive ground models.

  • Factors affecting the interpretation of pressuremeter tests

    by B.G. Clarke

    It is assumed that the probe is ‘wished’ into place causing no change to the properties of the ground, that the initial pressure acting on the probe is equal to the in situ stress, that the ground contains no discontinuities and that the material is uniform over the length of the expanding section when analysing pressuremeter tests. This is not the case, as all pressuremeters disturb the ground to some extent during installation and the ground is spatially variable. A review of the effects that installation, probe geometry and ground properties have upon the derived parameters suggests that their influence can be significant. These facts should be taken into account when interpreting a test but, given the level of uncertainty of the spatial variation of the composition and properties of the ground after a probe is installed, it is better to use the simple models to determine the ground properties or determine design parameters directly.

  • Pressuremeter probes and testing equipment

    by B.G. Clarke

    Pressuremeters are designed to simulate the expansion of an infinitely long cylindrical cavity. Tricells have inflatable guard cells to ensure that the central section expands as a cylinder; the lengths of monocells means that the end restriction has little effect on the assumption of a cylindrical expansion. The control and monitoring systems depend on whether changes in volume or displacement are measured; the test is stress- or strain-controlled; the monitoring and control systems are downhole or at the surface; oil, gas or water are used to expand the membrane; and the method to record the data. Examples of commercially available pressuremeters are used to highlight the differences between the probes. Prebored pressuremeters can be used in any ground condition. Self-boring pressuremeters were developed for soils, though they can be used in weak rocks if sufficiently robust. Pushed-in pressuremeters are used in soils.

  • Site operations

    by B.G. Clarke

    The results of a pressuremeter test are a function of the instrument used, the installation procedure, the test procedure and the methods of analysis and interpretation. The installation procedure should produce repeatable, minimum disturbance to the ground regardless of whether a pocket is created for a prebored pressuremeter, or the pressuremeter is drilled or pushed into place. Transducers, membranes and system compliance have to be calibrated at the beginning and end of a project and when there is a major change to the probe. Membrane calibrations are also carried out when a membrane is changed. Tests are designed to measure different parameters including in situ stress, modulus, strength, permeability and creep which are derived from the test curve using theories of cavity expansion. There are several test procedures some of which are set out in national and international standards.

  • Choosing and specifying a pressuremeter

    by B.G. Clarke

    There is a range of pressuremeters such that a form of pressuremeter can be chosen for any ground condition. There are a number of national and international standards that specify the probe and its calibrations, installation and test procedures and methods of interpretation. Tests can be used to obtain design parameters directly, determine ground properties, as a control for ground improvement schemes and to validate constitutive models. An aim is to install a pressuremeter with minimum or repeatable disturbance. Hence, skilled operators should be employed. A site investigation should be designed at the outset to drill boreholes and test pockets to undertake quality pressuremeter tests. Tests can be interpreted using empirical, semi-theoretical, theoretical and numerical methods. There are many published case studies of ground properties produced from pressuremeter tests in establishing site-specific correlations with results from other test types, in predicting ground response to loading or unloading, and in design of geotechnical structures.