BIST for Measuring Clock Jitter of Charge-Pump Phase-Locked Loops
Authors:
- 7 January 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 57 (2) , 276-285
Abstract
This paper presents a built-in self-test (BIST) circuit that measures the clock jitter of the charge-pump phase-locked loops (PLLs). The jitter-measurement structure is based on a novel time-to-digital converter (TDC) which has a high resolution. A small area overhead is also achieved using the voltage-controlled oscillator and the loop filter of the PLL under test as parts of the TDC. The experiment result shows that the resolution is about 1 ps and that the measurement error is smaller than 20%.Keywords
This publication has 11 references indexed in Scilit:
- A Digital BIST Methodology for Spread Spectrum Clock Generators2006
- An on-chip jitter measurement circuit with sub-picosecond resolution2005
- High accuracy jitter measurement using cyclic pulse width modulation structure2005
- A programmable on-chip picosecond jitter-measurement circuit without a reference-clock input2005
- Self-Refereed On-Chip Jitter Measurement Circuit Using Vernier Oscillators2005
- Experimental results for high-speed jitter measurement technique2005
- On-chip calibration technique for delay line based BIST jitter measurement2004
- Time-to-voltage converter for on-chip jitter measurementIEEE Transactions on Instrumentation and Measurement, 2003
- BIST for phase-locked loops in digital applications2003
- Circuits for on-chip sub-nanosecond signal capture and characterization2002