Abstract
Background: In 2023, the National Clinical Guidelines for Stroke revised the recommended daily multidisciplinary therapy dose from 45 minutes per therapy to 3 hours of therapy overall. To monitor the achievement of these guidelines, there is a need for accurate measurement. This study introduces a novel co-designed digital dosage tracking system that uses Near Field Communication technology to log rehabilitation activities and demonstrates its feasibility and accuracy in a clinical setting through comparison with the current clinical method of manual recording. Objective: This study aimed to assess the validity, feasibility, and usability of a novel co-designed digital tracker using Near Field Communication technology to automatically log rehabilitation dosage in people with stroke history, providing an objective and low-burden solution for clinical environments. Methods: This pilot mixed methods study included 2 phases. Phase 1 involved a usability trial with 9 participants conducted at a university research center, assessing usability with the System Usability Scale (SUS) and Intrinsic Motivation Inventory (IMI). Phase 2 consisted of a clinical trial in a National Health Service stroke ward with 15 inpatients, comparing the digital tracker with manual therapist recordings for validity and feasibility using paired t tests, Cohen d, and Bland-Altman plots. An acceptable discrepancy range was set at ±5%‐10%. Results: The digital tracker demonstrated high usability with a mean SUS score of 91.43 (SD 9.53) and strong user satisfaction (IMI score 6.29/7, SD 1.50). Clinical trial results showed a strong agreement between the digital and manual methods (t206=−1.60; P=.11; Cohen d=−0.06), with a small mean time discrepancy of 1.23 (SD 11.01) minutes across 207 activities. The Bland-Altman plot indicated good accuracy and consistency between methods, with limits of agreement within the clinically acceptable range. Conclusions: The co-designed digital tracker has been shown to agree with a manual method for recording rehabilitation dosage. This development presents the opportunity for objective, automated, and low-burden recording of rehabilitation dose to support prescription, monitoring, and research.Keywords
This publication has 17 references indexed in Scilit:
- An Intensive Exercise Program Using a Technology-Enriched Rehabilitation Gym for the Recovery of Function in People With Chronic Stroke: Usability StudyJMIR Rehabilitation and Assistive Technologies, 2023
- Investigating and Measuring Usability in Wearable Systems: A Structured Methodology and Related ProtocolApplied Sciences, 2023
- A new framework for developing and evaluating complex interventions: update of Medical Research Council guidanceBMJ, 2021
- Stroke survivors’ priorities for research related to life after strokeTopics in Stroke Rehabilitation, 2020
- Factors influencing the amount of therapy received during inpatient stroke care: an analysis of data from the UK Sentinel Stroke National Audit ProgrammeClinical Rehabilitation, 2020
- Comparing the Usability and Acceptability of Wearable Sensors Among Older Irish Adults in a Real-World Context: Observational StudyJMIR mHealth and uHealth, 2020
- Human Factors and Usability for Health Information Technology: Old and New ChallengesYearbook of Medical Informatics, 2019
- Usability and Clinical Application Design2010
- Intracranial pressure monitoring in intensive care: clinical advantages of a computerized system over manual recordingCritical Care, 2007
- Rehabilitation after StrokeNew England Journal of Medicine, 2005