Andrew Kerr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Andrew Kerr has a total of 172 co-authors. Here are the top co-authors by number of shared publications:
- Philip Rowe
Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
25 shared publications - Madeleine Grealy
Psychology University of Strathclyde Glasgow UK
10 shared publications - Milena Slachetka
Biomedical Engineering University of Strathclyde Glasgow UK
9 shared publications - Gillian Sweeney
Occupational Therapy Department, University Hospital Wishaw, NHS Lanarkshire, Wishaw, United Kingdom
8 shared publications - Lina Stankovic
Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow G1 1XW, UK
8 shared publications - Vladimir Stankovic
University of Strathclyde
8 shared publications
Latest Publications
- Open Access
- 17 October 2026
- Published by Elsevier in SSRN Electronic Journal
Baseline gait biomechanics distinguish responders from poor responders following technology-enriched rehabilitation in chronic stroke
BackgroundWalking recovery is a major goal after stroke, but outcomes vary considerably. Understanding the biomechanical factors associated with this variability may identify individuals more likely to benefit from rehabilitation and inform personalised interventions. This study examined whether baseline gait biomechanics distinguished individuals who achieved clinically meaningful improvements in walking speed (>0.16 m/s) following rehabilitation and characterised biomechanical changes associated with improvement.MethodsAdults with chronic stroke (>12 months post ictus) and residual motor impairment participated in an eight-week technology-enriched rehabilitation programme incorporating treadmill-based gait training, balance, strength and upper-limb rehabilitation within supervised circuit-based classes. Three-dimensional motion capture of comfortable overground walking was performed before and after rehabilitation to derive measures of trailing limb angle, foot clearance, cadence, smoothness, single-limb support and temporal gait symmetry.FindingsWalking speed increased (0.20 m/s, p<0.001) across the group (n=43), accompanied by increased cadence (4.17 steps/min, p<0.01). Gait pattern showed little change, including trailing limb angle (p=0.941) and temporal symmetry (p=0.29). Participants achieving clinically meaningful improvement demonstrated a more favourable biomechanical profile at baseline, including greater trailing limb angles and improved temporal symmetry. Logistic regression identified baseline trailing limb angles and single-limb support symmetry as significant predictors of clinically meaningful improvement.InterpretationTechnology-enriched rehabilitation improved walking speed in people with chronic stroke, primarily through increased cadence rather than substantial changes in gait mechanics. A more favourable baseline biomechanical profile was associated with clinically meaningful improvement, suggesting gait biomechanics may help identify individuals most likely to benefit from rehabilitation and support personalised treatment approaches.
- 17 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBaseline gait biomechanics distinguish responders from poor responders following technology-enriched rehabilitation in chronic stroke
BackgroundWalking recovery is a major goal after stroke, but outcomes vary considerably. Understanding the biomechanical factors associated with this variability may identify individuals more likely to benefit from rehabilitation and inform personalised interventions. This study examined whether baseline gait biomechanics distinguished individuals who achieved clinically meaningful improvements in walking speed (>0.16 m/s) following rehabilitation and characterised biomechanical changes associated with improvement.MethodsAdults with chronic stroke (>12 months post ictus) and residual motor impairment participated in an eight-week technology-enriched rehabilitation programme incorporating treadmill-based gait training, balance, strength and upper-limb rehabilitation within supervised circuit-based classes. Three-dimensional motion capture of comfortable overground walking was performed before and after rehabilitation to derive measures of trailing limb angle, foot clearance, cadence, smoothness, single-limb support and temporal gait symmetry.FindingsWalking speed increased (0.20 m/s, p<0.001) across the group (n=43), accompanied by increased cadence (4.17 steps/min, p<0.01). Gait pattern showed little change, including trailing limb angle (p=0.941) and temporal symmetry (p=0.29). Participants achieving clinically meaningful improvement demonstrated a more favourable biomechanical profile at baseline, including greater trailing limb angles and improved temporal symmetry. Logistic regression identified baseline trailing limb angles and single-limb support symmetry as significant predictors of clinically meaningful improvement.InterpretationTechnology-enriched rehabilitation improved walking speed in people with chronic stroke, primarily through increased cadence rather than substantial changes in gait mechanics. A more favourable baseline biomechanical profile was associated with clinically meaningful improvement, suggesting gait biomechanics may help identify individuals most likely to benefit from rehabilitation and support personalised treatment approaches.
- Open Access
- 19 August 2026
- Published by Wiley in Physiotherapy Research International
- Vol. 31 (4) , e70321
Intensive, Multi‐Technology Rehabilitation Programme for Chronic Stroke Survivors: Outcomes of a Phase I Single‐Arm Repeated‐Measures Study
Background: Effective rehabilitation interventions are needed to support recovery in people living with long‐term post‐stroke disability. Cocreation has been proposed as a method for enhancing the acceptability of technology‐supported rehabilitation and may improve rehabilitation outcomes. Objective: To observe changes in outcome following participation in a multi‐technology rehabilitation intervention for motor recovery in people with chronic stroke and to explore factors associated with differential response. Design: Pre–post, single‐arm intervention study. Methods: Participants with stroke ≥ 12 months previously and persistent motor impairment, completed an 8‐week, group‐based circuit class incorporating multiple rehabilitation technologies. Standardised measures of activity and participation were collected at baseline, pre‐intervention, and post‐intervention. Results: Sixty‐seven participants (mean age 60.49 ± 14.44 years; mean 41.87 ± 41.31 months post‐stroke) were enroled and 59 (88.06%) completed a mean of 18.52 ± 6.44 sessions. Eight did not complete, mainly due to transport or illness. Statistically significant ( p < 0.05) changes from pre‐to post‐intervention were observed across all outcomes. Subgroup analysis showed that participants with poorer balance, upper‐limb function and global disability at baseline showed greater pre–post improvements than higher‐functioning participants. Conclusions: Improvements in mobility and global function were observed following participation in a cocreated, multi‐technology group rehabilitation programme for people with chronic stroke. Greater pre–post improvements were observed among participants with greater initial disability. These preliminary findings need confirmation in controlled studies. Trial Registration: Clinical Trial registration: NCT06787768.
- 19 August 2026
- Published by Wiley in Physiotherapy Research International
- Vol. 31 (4) , e70321
Open AccessIntensive, Multi‐Technology Rehabilitation Programme for Chronic Stroke Survivors: Outcomes of a Phase I Single‐Arm Repeated‐Measures Study
Background: Effective rehabilitation interventions are needed to support recovery in people living with long‐term post‐stroke disability. Cocreation has been proposed as a method for enhancing the acceptability of technology‐supported rehabilitation and may improve rehabilitation outcomes. Objective: To observe changes in outcome following participation in a multi‐technology rehabilitation intervention for motor recovery in people with chronic stroke and to explore factors associated with differential response. Design: Pre–post, single‐arm intervention study. Methods: Participants with stroke ≥ 12 months previously and persistent motor impairment, completed an 8‐week, group‐based circuit class incorporating multiple rehabilitation technologies. Standardised measures of activity and participation were collected at baseline, pre‐intervention, and post‐intervention. Results: Sixty‐seven participants (mean age 60.49 ± 14.44 years; mean 41.87 ± 41.31 months post‐stroke) were enroled and 59 (88.06%) completed a mean of 18.52 ± 6.44 sessions. Eight did not complete, mainly due to transport or illness. Statistically significant ( p < 0.05) changes from pre‐to post‐intervention were observed across all outcomes. Subgroup analysis showed that participants with poorer balance, upper‐limb function and global disability at baseline showed greater pre–post improvements than higher‐functioning participants. Conclusions: Improvements in mobility and global function were observed following participation in a cocreated, multi‐technology group rehabilitation programme for people with chronic stroke. Greater pre–post improvements were observed among participants with greater initial disability. These preliminary findings need confirmation in controlled studies. Trial Registration: Clinical Trial registration: NCT06787768.
- Open Access
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
Beyond the Clinic: A Comparison of Free-Living and Gait Laboratory Symmetry Measurements in a Chronic Hemiplegic Stroke Population
Laboratory based gait analysis does not provide ecologically valid, or rehabilitation focused, data for practitioners. Wearable sensors have the potential to not only overcome this, enabling greater personalisation of rehabilitation, but also improve the data available for research. The aim of this study was to determine differences in a commonly recorded rehabilitation parameter after stroke, stance duration symmetry, when measured in a laboratory setting compared to free living environments using wearable sensors and a gait event (initial and final foot contact) detection algorithm. Stroke participants (n=34) and a healthy control (n=8) performed a 10m walk, at self-selected comfortable speed, in a gait laboratory equipped with 3D motion capture (Vicon). They then wore two ActivPAL 4+ sensors for four whole days at home. Stance phase symmetry was calculated with the Robinson index, using stance durations (initial contact to final contact) derived from both systems. There was a statistically significant difference in symmetry between FL and gait laboratory (Kruskal-Wallis p < 0.01, H(1) = 20.69) with the Bland-Altman analysis showing an increasing difference as the average symmetry increased (bias = 12.33%, limits of agreement = -19.63%, 44.29%, slope = 1.17). These findings clearly demonstrate the differences in walking performance between a formal testing environment and the real world, with more asymmetrical patterns observed during FL. This finding once again highlights the need to accurately observe real world walking outside the laboratory and has the potential to be developed into tools to support personalised rehabilitation and self-management.
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBeyond the Clinic: A Comparison of Free-Living and Gait Laboratory Symmetry Measurements in a Chronic Hemiplegic Stroke Population
Laboratory based gait analysis does not provide ecologically valid, or rehabilitation focused, data for practitioners. Wearable sensors have the potential to not only overcome this, enabling greater personalisation of rehabilitation, but also improve the data available for research. The aim of this study was to determine differences in a commonly recorded rehabilitation parameter after stroke, stance duration symmetry, when measured in a laboratory setting compared to free living environments using wearable sensors and a gait event (initial and final foot contact) detection algorithm. Stroke participants (n=34) and a healthy control (n=8) performed a 10m walk, at self-selected comfortable speed, in a gait laboratory equipped with 3D motion capture (Vicon). They then wore two ActivPAL 4+ sensors for four whole days at home. Stance phase symmetry was calculated with the Robinson index, using stance durations (initial contact to final contact) derived from both systems. There was a statistically significant difference in symmetry between FL and gait laboratory (Kruskal-Wallis p < 0.01, H(1) = 20.69) with the Bland-Altman analysis showing an increasing difference as the average symmetry increased (bias = 12.33%, limits of agreement = -19.63%, 44.29%, slope = 1.17). These findings clearly demonstrate the differences in walking performance between a formal testing environment and the real world, with more asymmetrical patterns observed during FL. This finding once again highlights the need to accurately observe real world walking outside the laboratory and has the potential to be developed into tools to support personalised rehabilitation and self-management.
- Open Access
- 6 May 2026
- Published by Wiley in Advanced Functional Materials
Texoskeletons: Developing the Fundamental Technologies for Creating Intelligent Soft Robotic Clothing With Integrated 1D Sensors and Actuators
Traditional wearable exoskeletons rely on rigid structures, which limit comfort, flexibility, and everyday usability. This work introduces the fundamental technologies to create the first soft, lightweight, intelligent textile‐based exoskeletons (Texoskeletons) built using 1D sensors and actuators. This new approach ensures that the textiles maintain most of its conformability and allows the devices to be positioned anywhere on the body. Two different structural architectures of pneumatic 1D actuators are evaluated: single‐material and two‐material actuators. The two‐material actuators display intrinsic bending behavior and perform better when positioned within knitted textiles, while single‐material actuators deliver superior lifting performance. When three of these actuators are grouped within the textile, they lift loads exceeding 300 g. Additionally, the Texoskeleton comprises of novel 1D triboelectric sensors to capture user movements. After training a machine learning algorithm, the 1D triboelectric sensors classify wrist flexion–extension, ulnar–radial deviation, supination, and pronation with an accuracy of 85.71%. A wrist‐worn prototype Texoskeleton sleeve incorporating 14 actuators and 4 sensors is created to demonstrate the device's lightweight and wearability. This technology has the potential to revolutionize personalized rehabilitation, immersive training, and human–machine interaction, paving the way for intelligent everyday clothing that adapts to user movements and needs in real‐time.
- 6 May 2026
- Published by Wiley in Advanced Functional Materials
Open AccessTexoskeletons: Developing the Fundamental Technologies for Creating Intelligent Soft Robotic Clothing With Integrated 1D Sensors and Actuators
Traditional wearable exoskeletons rely on rigid structures, which limit comfort, flexibility, and everyday usability. This work introduces the fundamental technologies to create the first soft, lightweight, intelligent textile‐based exoskeletons (Texoskeletons) built using 1D sensors and actuators. This new approach ensures that the textiles maintain most of its conformability and allows the devices to be positioned anywhere on the body. Two different structural architectures of pneumatic 1D actuators are evaluated: single‐material and two‐material actuators. The two‐material actuators display intrinsic bending behavior and perform better when positioned within knitted textiles, while single‐material actuators deliver superior lifting performance. When three of these actuators are grouped within the textile, they lift loads exceeding 300 g. Additionally, the Texoskeleton comprises of novel 1D triboelectric sensors to capture user movements. After training a machine learning algorithm, the 1D triboelectric sensors classify wrist flexion–extension, ulnar–radial deviation, supination, and pronation with an accuracy of 85.71%. A wrist‐worn prototype Texoskeleton sleeve incorporating 14 actuators and 4 sensors is created to demonstrate the device's lightweight and wearability. This technology has the potential to revolutionize personalized rehabilitation, immersive training, and human–machine interaction, paving the way for intelligent everyday clothing that adapts to user movements and needs in real‐time.
- Open Access
- 30 October 2025
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 10, e80308
Thigh-Worn Sensor for Measuring Initial and Final Contact During Gait in a Mobility Impaired Population: Validation Study
Background: Adapting physical activity monitors to detect gait events (ie, at initial and final contact) has the potential to build a more personalized approach to gait rehabilitation after stroke. Meeting laboratory standards for detecting these events in impaired populations is challenging, without resorting to a multisensor solution. The Teager-Kaiser energy operator (TKEO) estimates the instantaneous energy of a signal; its enhanced sensitivity has successfully detected gait events from the acceleration signals of individuals with impaired mobility, but has not been applied to stroke. Objective: This study aimed to test the criterion validity of TKEO gait event detection (and derived spatiotemporal metrics) using data from thigh mounted physical activity monitors compared with concurrent 3D motion capture in chronic survivors of stroke. Methods: Participants with a history of stroke(n=13, mean age 59, SD 14 years), time since stroke (mean 1.5, SD 0.5 years), walking speed (mean 0.93 ms −1 , SD 0.38 m/s) performed two 10m walks at their comfortable speed, while wearing two ActivPAL 4+ (AP4) sensors (anterior of both thighs) and LED cluster markers on the pelvis and ankles which were tracked by a motion capture system. The TKEO signal processing technique was then used to extract gait events (initial and final contact) and calculate stance durations which were compared with motion capture data. Results: There was very good agreement between the AP4 and motion capture data for stance duration (AP4 0.85s, motion capture system 0.88s, 95% CI of difference −0.07 to 0.13, intraclass correlation coefficient [3,1]=0.79). Conclusions: The TKEO method for gait event detection using AP4 data provides stance time durations that are comparable with laboratory-based systems in a population with chronic stroke. Providing accurate stance time durations from wearable sensors could extend gait training out of clinical environments. Limitations include ecological and external validity. Future work should confirm findings with a larger sample of participants with a history of stroke.
- 30 October 2025
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 10, e80308
Open AccessThigh-Worn Sensor for Measuring Initial and Final Contact During Gait in a Mobility Impaired Population: Validation Study
Background: Adapting physical activity monitors to detect gait events (ie, at initial and final contact) has the potential to build a more personalized approach to gait rehabilitation after stroke. Meeting laboratory standards for detecting these events in impaired populations is challenging, without resorting to a multisensor solution. The Teager-Kaiser energy operator (TKEO) estimates the instantaneous energy of a signal; its enhanced sensitivity has successfully detected gait events from the acceleration signals of individuals with impaired mobility, but has not been applied to stroke. Objective: This study aimed to test the criterion validity of TKEO gait event detection (and derived spatiotemporal metrics) using data from thigh mounted physical activity monitors compared with concurrent 3D motion capture in chronic survivors of stroke. Methods: Participants with a history of stroke(n=13, mean age 59, SD 14 years), time since stroke (mean 1.5, SD 0.5 years), walking speed (mean 0.93 ms −1 , SD 0.38 m/s) performed two 10m walks at their comfortable speed, while wearing two ActivPAL 4+ (AP4) sensors (anterior of both thighs) and LED cluster markers on the pelvis and ankles which were tracked by a motion capture system. The TKEO signal processing technique was then used to extract gait events (initial and final contact) and calculate stance durations which were compared with motion capture data. Results: There was very good agreement between the AP4 and motion capture data for stance duration (AP4 0.85s, motion capture system 0.88s, 95% CI of difference −0.07 to 0.13, intraclass correlation coefficient [3,1]=0.79). Conclusions: The TKEO method for gait event detection using AP4 data provides stance time durations that are comparable with laboratory-based systems in a population with chronic stroke. Providing accurate stance time durations from wearable sensors could extend gait training out of clinical environments. Limitations include ecological and external validity. Future work should confirm findings with a larger sample of participants with a history of stroke.
- Open Access
- 8 October 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Intensive, Multi-Technology Rehabilitation programme for Chronic Stroke Survivors: A Phase I single-arm repeated-measures study (Preprint)
BACKGROUND The need to meet minimum guideline recommendations for rehabilitation after stroke motivated the cocreation of a multi-technology enriched rehabilitation gym (TERG). Previous research has established the feasibility and acceptability of this approach in chronic and sub-acute stroke populations. OBJECTIVE This study aimed to gather preliminary evidence, and effect sizes, on the effectiveness of a multi-technology intervention for motor recovery in a chronic stroke population and identify factors that explain variation in response. METHODS This was a Pre-Post, single arm study design located in a rehabilitation research centre. Participants had a diagnosis of stroke, at least 12 months previously, with consequent motor disability. Following baseline measures, an 8-week exercise program using the TERG (e.g., virtual reality treadmills, power-assisted equipment, balance trainers, and upper limb training systems) was individually tailored by a physiotherapist in partnership with participants. Standard measures of activity and participation were recorded two weeks before (baseline), immediately before and immediately post (outcome) intervention. RESULTS Sixty-seven individuals participated, mean age 60.49 (SD 14.44) years, 41.87 (41.31) months since stroke, 51 were male, 26 had aphasia, mean MoCa score of 25.56 (6 to 30). Eight individuals (11.94%) did not complete the programme (transport difficulties n=5, illness n=1, unknown n=2), five withdrawing before baseline. The remaining 59 participants (88.06%) completed an average of 18.12 (SD 6.49,10-38) two-hour sessions. There were statistically significant (p <.05) improvements from baseline to outcome on every variable, with varying effect sizes. Cluster analysis distinguished two sub-groups. Group 1 (n = 20) had poorer balance, arm function and global disability scores at baseline but showed greater improvement than group 1 (n=47) who were younger with higher functioning at baseline. CONCLUSIONS This study assessed the impact of a novel cocreated, multi-technology, rehabilitation intervention on mobility and global function of people in the chronic phase of stroke recover. The results show overall improvement with the greatest improvement observed among participants with greater initial levels of disability. CLINICALTRIAL NCT06787768
- 8 October 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessIntensive, Multi-Technology Rehabilitation programme for Chronic Stroke Survivors: A Phase I single-arm repeated-measures study (Preprint)
BACKGROUND The need to meet minimum guideline recommendations for rehabilitation after stroke motivated the cocreation of a multi-technology enriched rehabilitation gym (TERG). Previous research has established the feasibility and acceptability of this approach in chronic and sub-acute stroke populations. OBJECTIVE This study aimed to gather preliminary evidence, and effect sizes, on the effectiveness of a multi-technology intervention for motor recovery in a chronic stroke population and identify factors that explain variation in response. METHODS This was a Pre-Post, single arm study design located in a rehabilitation research centre. Participants had a diagnosis of stroke, at least 12 months previously, with consequent motor disability. Following baseline measures, an 8-week exercise program using the TERG (e.g., virtual reality treadmills, power-assisted equipment, balance trainers, and upper limb training systems) was individually tailored by a physiotherapist in partnership with participants. Standard measures of activity and participation were recorded two weeks before (baseline), immediately before and immediately post (outcome) intervention. RESULTS Sixty-seven individuals participated, mean age 60.49 (SD 14.44) years, 41.87 (41.31) months since stroke, 51 were male, 26 had aphasia, mean MoCa score of 25.56 (6 to 30). Eight individuals (11.94%) did not complete the programme (transport difficulties n=5, illness n=1, unknown n=2), five withdrawing before baseline. The remaining 59 participants (88.06%) completed an average of 18.12 (SD 6.49,10-38) two-hour sessions. There were statistically significant (p <.05) improvements from baseline to outcome on every variable, with varying effect sizes. Cluster analysis distinguished two sub-groups. Group 1 (n = 20) had poorer balance, arm function and global disability scores at baseline but showed greater improvement than group 1 (n=47) who were younger with higher functioning at baseline. CONCLUSIONS This study assessed the impact of a novel cocreated, multi-technology, rehabilitation intervention on mobility and global function of people in the chronic phase of stroke recover. The results show overall improvement with the greatest improvement observed among participants with greater initial levels of disability. CLINICALTRIAL NCT06787768
- Open Access
- 14 May 2025
- Published by JMIR Publications Inc. in JMIR Rehabilitation and Assistive Technologies
- Vol. 12 (1) , e68129
Co-Designed Digital Device for Tracking Rehabilitation Dosage in a Clinical Environment After Stroke: Mixed Methods Validity and Feasibility Study
Background: In 2023, the National Clinical Guidelines for Stroke revised the recommended daily multidisciplinary therapy dose from 45 minutes per therapy to 3 hours of therapy overall. To monitor the achievement of these guidelines, there is a need for accurate measurement. This study introduces a novel co-designed digital dosage tracking system that uses Near Field Communication technology to log rehabilitation activities and demonstrates its feasibility and accuracy in a clinical setting through comparison with the current clinical method of manual recording. Objective: This study aimed to assess the validity, feasibility, and usability of a novel co-designed digital tracker using Near Field Communication technology to automatically log rehabilitation dosage in people with stroke history, providing an objective and low-burden solution for clinical environments. Methods: This pilot mixed methods study included 2 phases. Phase 1 involved a usability trial with 9 participants conducted at a university research center, assessing usability with the System Usability Scale (SUS) and Intrinsic Motivation Inventory (IMI). Phase 2 consisted of a clinical trial in a National Health Service stroke ward with 15 inpatients, comparing the digital tracker with manual therapist recordings for validity and feasibility using paired t tests, Cohen d, and Bland-Altman plots. An acceptable discrepancy range was set at ±5%‐10%. Results: The digital tracker demonstrated high usability with a mean SUS score of 91.43 (SD 9.53) and strong user satisfaction (IMI score 6.29/7, SD 1.50). Clinical trial results showed a strong agreement between the digital and manual methods (t206=−1.60; P=.11; Cohen d=−0.06), with a small mean time discrepancy of 1.23 (SD 11.01) minutes across 207 activities. The Bland-Altman plot indicated good accuracy and consistency between methods, with limits of agreement within the clinically acceptable range. Conclusions: The co-designed digital tracker has been shown to agree with a manual method for recording rehabilitation dosage. This development presents the opportunity for objective, automated, and low-burden recording of rehabilitation dose to support prescription, monitoring, and research.
- 14 May 2025
- Published by JMIR Publications Inc. in JMIR Rehabilitation and Assistive Technologies
- Vol. 12 (1) , e68129
Open AccessCo-Designed Digital Device for Tracking Rehabilitation Dosage in a Clinical Environment After Stroke: Mixed Methods Validity and Feasibility Study
Background: In 2023, the National Clinical Guidelines for Stroke revised the recommended daily multidisciplinary therapy dose from 45 minutes per therapy to 3 hours of therapy overall. To monitor the achievement of these guidelines, there is a need for accurate measurement. This study introduces a novel co-designed digital dosage tracking system that uses Near Field Communication technology to log rehabilitation activities and demonstrates its feasibility and accuracy in a clinical setting through comparison with the current clinical method of manual recording. Objective: This study aimed to assess the validity, feasibility, and usability of a novel co-designed digital tracker using Near Field Communication technology to automatically log rehabilitation dosage in people with stroke history, providing an objective and low-burden solution for clinical environments. Methods: This pilot mixed methods study included 2 phases. Phase 1 involved a usability trial with 9 participants conducted at a university research center, assessing usability with the System Usability Scale (SUS) and Intrinsic Motivation Inventory (IMI). Phase 2 consisted of a clinical trial in a National Health Service stroke ward with 15 inpatients, comparing the digital tracker with manual therapist recordings for validity and feasibility using paired t tests, Cohen d, and Bland-Altman plots. An acceptable discrepancy range was set at ±5%‐10%. Results: The digital tracker demonstrated high usability with a mean SUS score of 91.43 (SD 9.53) and strong user satisfaction (IMI score 6.29/7, SD 1.50). Clinical trial results showed a strong agreement between the digital and manual methods (t206=−1.60; P=.11; Cohen d=−0.06), with a small mean time discrepancy of 1.23 (SD 11.01) minutes across 207 activities. The Bland-Altman plot indicated good accuracy and consistency between methods, with limits of agreement within the clinically acceptable range. Conclusions: The co-designed digital tracker has been shown to agree with a manual method for recording rehabilitation dosage. This development presents the opportunity for objective, automated, and low-burden recording of rehabilitation dose to support prescription, monitoring, and research.
- Open Access
- 18 April 2025
- Published by SAGE Publications in Clinical Rehabilitation
- Vol. 39 (6) , 740-749
A technology-enriched approach to increasing rehabilitation dose after stroke: Clinical feasibility study
Objective: To assess the feasibility of a multi-technology, group based, approach to increasing rehabilitation dose early after stroke. Methods: Mixed methods design reporting recruitment, dropout, safety, dose and acceptability. Setting: Acute Hospital Stroke Unit Participants: Sixty stroke patients, 9.0 median (IQR 12.8) days after stroke, referred for rehabilitation, without contraindications to light exercise. Intervention: Personalised rehabilitation delivered in supervised groups, using a multi-technology rehabilitation gym, in addition to usual care. Main measures: Feasibility was based on achieving recruitment rates over 3.2 per month, dropout rates below 6%, absence of suspected unexpected serious adverse reactions and shoulder pain prevalence below 60%. Acceptability was derived from interviews with the clinical team. Dose (rehabilitation time) was recorded manually. Function was measured with the modified Rivermead Mobility Index and Therapy Outcome Measure. Results: Feasibility was satisfactory with high recruitment rates (6 per month), low dropout (2%), no suspected unexpected serious adverse reactions and low prevalence (19%) of shoulder pain. Thematic analysis of interview data indicated the clinical team (n = 9) found the intervention acceptable and identified organisational constraints to higher doses. Participants attended an average of 9.1 (1–32) sessions during their hospital stay (23.0 days, SD 19.7), with sessions lasting 52 min (SD 15.7), on average. The modified Rivermead Mobility Index and Therapy Outcome Measure increased by 17.9 (SD 8.6) and 5.7 points (SD 2.4), respectively. Conclusions: Strong feasibility findings support future trials of multi-technology, group-based rehabilitation. This novel approach is an encouraging step toward achieving recommended doses of rehabilitation after stroke but needs further investigation.
- 18 April 2025
- Published by SAGE Publications in Clinical Rehabilitation
- Vol. 39 (6) , 740-749
Open AccessA technology-enriched approach to increasing rehabilitation dose after stroke: Clinical feasibility study
Objective: To assess the feasibility of a multi-technology, group based, approach to increasing rehabilitation dose early after stroke. Methods: Mixed methods design reporting recruitment, dropout, safety, dose and acceptability. Setting: Acute Hospital Stroke Unit Participants: Sixty stroke patients, 9.0 median (IQR 12.8) days after stroke, referred for rehabilitation, without contraindications to light exercise. Intervention: Personalised rehabilitation delivered in supervised groups, using a multi-technology rehabilitation gym, in addition to usual care. Main measures: Feasibility was based on achieving recruitment rates over 3.2 per month, dropout rates below 6%, absence of suspected unexpected serious adverse reactions and shoulder pain prevalence below 60%. Acceptability was derived from interviews with the clinical team. Dose (rehabilitation time) was recorded manually. Function was measured with the modified Rivermead Mobility Index and Therapy Outcome Measure. Results: Feasibility was satisfactory with high recruitment rates (6 per month), low dropout (2%), no suspected unexpected serious adverse reactions and low prevalence (19%) of shoulder pain. Thematic analysis of interview data indicated the clinical team (n = 9) found the intervention acceptable and identified organisational constraints to higher doses. Participants attended an average of 9.1 (1–32) sessions during their hospital stay (23.0 days, SD 19.7), with sessions lasting 52 min (SD 15.7), on average. The modified Rivermead Mobility Index and Therapy Outcome Measure increased by 17.9 (SD 8.6) and 5.7 points (SD 2.4), respectively. Conclusions: Strong feasibility findings support future trials of multi-technology, group-based rehabilitation. This novel approach is an encouraging step toward achieving recommended doses of rehabilitation after stroke but needs further investigation.
- Open Access
- 29 October 2024
- Published by JMIR Publications Inc. in JMIR Preprints
A Co-designed Digital Device for Tracking Rehabilitation Dosage After Stroke: Validity and Feasibility Study in a Clinical Environment (Preprint)
BACKGROUND In 2023, the National Clinical Guidelines for Stroke revised the recommended daily multidisciplinary therapy dose from 45 minutes to 3 hours. To monitor the achievement of these guidelines there is a need for accurate measurement. This study introduces a novel co-designed digital dosage tracking system that utilises Near Field Communication (NFC) technology to log rehabilitation activities and demonstrates its feasibility and accuracy in a clinical setting through comparison with the current clinical method of manual recording. OBJECTIVE This study aimed to assess the validity, feasibility, and usability of a novel co-designed digital tracker using Near Field Communication (NFC) technology to automatically log rehabilitation dosage in stroke patients, providing an objective and low-burden solution for clinical environments. METHODS This pilot mixed-methods study included two phases. Phase 1 involved a usability trial with nine participants conducted at a university research centre, assessing usability with the System Usability Scale (SUS) and Intrinsic Motivation Inventory (IMI). Phase 2 consisted of a clinical trial in an NHS stroke ward with 15 inpatients, comparing the digital tracker with manual therapist recordings for validity and feasibility using paired t-tests, Cohen's D, and Bland-Altman plots. An acceptable discrepancy range was set at ±5-10%. RESULTS The digital tracker demonstrated high usability with a mean SUS score of 91.43 (SD = 9.53) and strong user satisfaction (IMI score 6.29/7, SD = 1.50). Clinical trial results showed a strong agreement between the digital and manual methods (t(207)=-1.55, P=.12, Cohen’s D=-0.06), with a small mean time discrepancy of 1.18 minutes (SD = 10.98) across 208 activities. The Bland-Altman plot indicated good accuracy and consistency between methods, with limits of agreement within the clinically acceptable range. CONCLUSIONS The co-designed digital tracker has been shown to agree with a manual method for recording rehabilitation dosage. This development presents the opportunity for objective, automated and low-burden recording of rehabilitation dose to support prescription, monitoring and research. CLINICALTRIAL ClinicalTrials.gov: NCT05981729 IRAS ID No. 329156
- 29 October 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessA Co-designed Digital Device for Tracking Rehabilitation Dosage After Stroke: Validity and Feasibility Study in a Clinical Environment (Preprint)
BACKGROUND In 2023, the National Clinical Guidelines for Stroke revised the recommended daily multidisciplinary therapy dose from 45 minutes to 3 hours. To monitor the achievement of these guidelines there is a need for accurate measurement. This study introduces a novel co-designed digital dosage tracking system that utilises Near Field Communication (NFC) technology to log rehabilitation activities and demonstrates its feasibility and accuracy in a clinical setting through comparison with the current clinical method of manual recording. OBJECTIVE This study aimed to assess the validity, feasibility, and usability of a novel co-designed digital tracker using Near Field Communication (NFC) technology to automatically log rehabilitation dosage in stroke patients, providing an objective and low-burden solution for clinical environments. METHODS This pilot mixed-methods study included two phases. Phase 1 involved a usability trial with nine participants conducted at a university research centre, assessing usability with the System Usability Scale (SUS) and Intrinsic Motivation Inventory (IMI). Phase 2 consisted of a clinical trial in an NHS stroke ward with 15 inpatients, comparing the digital tracker with manual therapist recordings for validity and feasibility using paired t-tests, Cohen's D, and Bland-Altman plots. An acceptable discrepancy range was set at ±5-10%. RESULTS The digital tracker demonstrated high usability with a mean SUS score of 91.43 (SD = 9.53) and strong user satisfaction (IMI score 6.29/7, SD = 1.50). Clinical trial results showed a strong agreement between the digital and manual methods (t(207)=-1.55, P=.12, Cohen’s D=-0.06), with a small mean time discrepancy of 1.18 minutes (SD = 10.98) across 208 activities. The Bland-Altman plot indicated good accuracy and consistency between methods, with limits of agreement within the clinically acceptable range. CONCLUSIONS The co-designed digital tracker has been shown to agree with a manual method for recording rehabilitation dosage. This development presents the opportunity for objective, automated and low-burden recording of rehabilitation dose to support prescription, monitoring and research. CLINICALTRIAL ClinicalTrials.gov: NCT05981729 IRAS ID No. 329156
- Open Access
A Novel Online Position Estimation Method and Movement Sonification System: The Soniccup
Existing methods to obtain position from inertial sensors typically use a combination of multiple sensors and orientation modeling; thus, obtaining position from a single inertial sensor is highly desirable given the decreased setup time and reduced complexity. The dead reckoning method is commonly chosen to obtain position from acceleration; however, when applied to upper limb tracking, the accuracy of position estimates are questionable, which limits feasibility. A new method of obtaining position estimates through the use of zero velocity updates is reported, using a commercial IMU, a push-to-make momentary switch, and a 3D printed object to house the sensors. The generated position estimates can subsequently be converted into sound through sonification to provide audio feedback on reaching movements for rehabilitation applications. An evaluation of the performance of the generated position estimates from a system labeled ‘Soniccup’ is presented through a comparison with the outputs from a Vicon Nexus system. The results indicate that for reaching movements below one second in duration, the Soniccup produces positional estimates with high similarity to the same movements captured through the Vicon system, corresponding to comparable audio output from the two systems. However, future work to improve the performance of longer-duration movements and reduce the system latency to produce real-time audio feedback is required to improve the acceptability of the system.
Open AccessA Novel Online Position Estimation Method and Movement Sonification System: The Soniccup
Existing methods to obtain position from inertial sensors typically use a combination of multiple sensors and orientation modeling; thus, obtaining position from a single inertial sensor is highly desirable given the decreased setup time and reduced complexity. The dead reckoning method is commonly chosen to obtain position from acceleration; however, when applied to upper limb tracking, the accuracy of position estimates are questionable, which limits feasibility. A new method of obtaining position estimates through the use of zero velocity updates is reported, using a commercial IMU, a push-to-make momentary switch, and a 3D printed object to house the sensors. The generated position estimates can subsequently be converted into sound through sonification to provide audio feedback on reaching movements for rehabilitation applications. An evaluation of the performance of the generated position estimates from a system labeled ‘Soniccup’ is presented through a comparison with the outputs from a Vicon Nexus system. The results indicate that for reaching movements below one second in duration, the Soniccup produces positional estimates with high similarity to the same movements captured through the Vicon system, corresponding to comparable audio output from the two systems. However, future work to improve the performance of longer-duration movements and reduce the system latency to produce real-time audio feedback is required to improve the acceptability of the system.