Abstract
Power transformer protection has a high sensitivity due to its important role in power systems. Various factors such as inrush and sympathetic inrush currents may result in the inappropriate performance of protective relays and cause problems such as power outage or blocking of sensitive loads. Until now, several studies have been performed on the detection and reduction of inrush current, however, the effect of sympathetic inrush current on transformer protection has not been addressed. In this study, the operation of the protection system during the sympathetic inrush current is comprehensively analysed. Furthermore, the use of a fault current limiter is proposed to reduce the undesirable effects of the phenomena. The effects of the limiter on the saturation of power and current transformers are investigated. A real transmission station is simulated using DIgSILENT Power Factory Software to perform these studies by considering the resistive and impedance fault current limiter. Results show that protective relays do not have an improper operation during the phenomena with limiters. Moreover, with the resistive fault current limiter, sympathetic inrush and inrush currents are decreased by 5 and 15% more than the impedance fault current limiter, respectively. Saturation of power and current transformers is significantly reduced with limiters, especially with a resistive fault current limiter.Keywords
This publication has 21 references indexed in Scilit:
- Using mathematical morphology to discriminate between internal fault and inrush current of transformersIET Generation, Transmission & Distribution, 2016
- Superconducting Fault Current Limiter Application for Reduction of the Transformer Inrush Current: A Decision Scheme of the Optimal Insertion ResistanceIEEE Transactions on Applied Superconductivity, 2010
- Characteristics of Inrush Current of Present Designs of Power Transformers2007 IEEE Power Engineering Society General Meeting, 2007
- Inrush-Current-Limiting With High$rm T_rm c$SuperconductorIEEE Transactions on Applied Superconductivity, 2005
- A current-based solution for transformer differential protection. II. Relay description and evaluationIEEE Transactions on Power Delivery, 2002
- Computation of inrush current forces on transformer windingsIEEE Transactions on Magnetics, 2001
- Elimination of transformer inrush currents by controlled switching. I. Theoretical considerationsIEEE Transactions on Power Delivery, 2001
- Elimination of transformer inrush currents by controlled switching. II. Application and performance considerationsIEEE Transactions on Power Delivery, 2001
- Reduction of inrush current in single-phase transformer using virtual air gap techniqueIEEE Transactions on Magnetics, 1998
- A Proposed Method of Harmonic Restraint Differential Protecting of Transformers by Digital ComputerIEEE Transactions on Power Apparatus and Systems, 1972