Yaser Damchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yaser Damchi has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Javad Sadeh
Department of Electrical Engineering, Faculty of Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
10 shared publications - Habib Rajabi Mashhadi
Department of Electrical Engineering, Faculty of Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
6 shared publications Matin Golpayegani
2 shared publicationsMohammad Dolatabadi
Department of Mathematics Vali‐e‐Asr University of Rafsanjan Rafsanjan Iran
2 shared publicationsMohammad Hossein Sadeghi
2 shared publications- Ahmadreza Eivazi
Faculty of Electrical Engineering, Shahrood University of Technology, Shahrood, Iran
1 shared publication
Latest Publications
- 4 September 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
A one-end current-based method for single line to ground fault location in the stitched transmission lines
- 4 September 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
A one-end current-based method for single line to ground fault location in the stitched transmission lines
- 9 July 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 263
Hybrid FDOST-based statistical approach for power transformer differential protection
- 9 July 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 263
Hybrid FDOST-based statistical approach for power transformer differential protection
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1) , e70465
A New Hybrid Method for Adaptive and Online Faulted Phase Selection in Power Transmission Lines
Faulted phase selection (FPS) is critical for the proper operation of protection systems. FPS is performed after fault detection, during which the relay observes signals whose characteristics vary depending on the fault detection time (FDT), including different levels of decaying induced transients mixed with the post‐fault cosine signal. However, numerous existing FPS methods overlook that fixed post‐fault sampling windows implicitly assume a known or fixed FDT and therefore do not address the variation or uncertainty in FDT encountered in relays. In this paper, it is demonstrated that the difference between the post‐fault and pre‐fault energy of voltage signals effectively represents the voltage drop component, based on which the voltage drop index (VDI) is proposed. Additionally, the induced transient index (ITI) is introduced based on the variance of the post‐fault voltage energy to estimate induced transients. By combining VDI and ITI, an adaptive fault classification index (AFCI) is proposed, in which the contribution of each index is adaptively adjusted using the Chatterjee correlation. By incorporating both aspects of fault characteristics, AFCI demonstrates the ability to classify faults across varying FDTs. The results indicate that the method accurately classifies faults across varying FDTs, even under noise and power swing conditions.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1) , e70465
Open AccessA New Hybrid Method for Adaptive and Online Faulted Phase Selection in Power Transmission Lines
Faulted phase selection (FPS) is critical for the proper operation of protection systems. FPS is performed after fault detection, during which the relay observes signals whose characteristics vary depending on the fault detection time (FDT), including different levels of decaying induced transients mixed with the post‐fault cosine signal. However, numerous existing FPS methods overlook that fixed post‐fault sampling windows implicitly assume a known or fixed FDT and therefore do not address the variation or uncertainty in FDT encountered in relays. In this paper, it is demonstrated that the difference between the post‐fault and pre‐fault energy of voltage signals effectively represents the voltage drop component, based on which the voltage drop index (VDI) is proposed. Additionally, the induced transient index (ITI) is introduced based on the variance of the post‐fault voltage energy to estimate induced transients. By combining VDI and ITI, an adaptive fault classification index (AFCI) is proposed, in which the contribution of each index is adaptively adjusted using the Chatterjee correlation. By incorporating both aspects of fault characteristics, AFCI demonstrates the ability to classify faults across varying FDTs. The results indicate that the method accurately classifies faults across varying FDTs, even under noise and power swing conditions.
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1) , e70396
A Negative‐Sequence Current‐Based Method for Asymmetrical Fault Location in Stitched Transmission Lines
Due to economic issues and the shortage of bays in high‐voltage substations, a special type of double‐circuit line called ‘stitched lines’ is used, which is connected to a bay at both ends. However, the connection of these lines to high‐voltage substations makes the current of each circuit unavailable separately. Therefore, fault location in these lines is challenging. In this paper, a new method based on a negative‐sequence network is proposed for locating asymmetrical faults using the current from the two ends of the line. It is notable that the proposed method is not affected by the mutual coupling between the two circuits and the transposition of the lines due to the use of a negative‐sequence network. The accuracy of the method for different asymmetrical faults at various locations with different fault resistances is evaluated by considering noise; uncertainty of the stitched line; and Thevenin impedances; sampling frequency change; fault inception angle; current transformer saturation; and fault clearing time, considering line shunt capacitance in all conditions. The obtained results indicate that the proposed method has appropriate performance in all scenarios, with an average error of less than 1% and a standard deviation of less than 0.5%.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1) , e70396
Open AccessA Negative‐Sequence Current‐Based Method for Asymmetrical Fault Location in Stitched Transmission Lines
Due to economic issues and the shortage of bays in high‐voltage substations, a special type of double‐circuit line called ‘stitched lines’ is used, which is connected to a bay at both ends. However, the connection of these lines to high‐voltage substations makes the current of each circuit unavailable separately. Therefore, fault location in these lines is challenging. In this paper, a new method based on a negative‐sequence network is proposed for locating asymmetrical faults using the current from the two ends of the line. It is notable that the proposed method is not affected by the mutual coupling between the two circuits and the transposition of the lines due to the use of a negative‐sequence network. The accuracy of the method for different asymmetrical faults at various locations with different fault resistances is evaluated by considering noise; uncertainty of the stitched line; and Thevenin impedances; sampling frequency change; fault inception angle; current transformer saturation; and fault clearing time, considering line shunt capacitance in all conditions. The obtained results indicate that the proposed method has appropriate performance in all scenarios, with an average error of less than 1% and a standard deviation of less than 0.5%.
- 20 November 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 253
A novel Markov model for reliability evaluation of communication systems in wide-area protection
- 20 November 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 253
A novel Markov model for reliability evaluation of communication systems in wide-area protection
- 28 October 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 252
Optimizing dual settings and operating characteristics of DOCRs, and DGs penetration incorporating PQ constraints
- 28 October 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 252
Optimizing dual settings and operating characteristics of DOCRs, and DGs penetration incorporating PQ constraints
- Open Access
- 8 December 2022
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-11
Reliability-Centered Maintenance for Overhead Transmission Lines in Composite Power System
Reliable overhead transmission lines have a vital role in maintaining the reliability of power systems at a desirable level and ensuring the continuity of electrical energy. In this regard, a proper preventive maintenance program can ensure the reliable functioning of transmission lines. Based on the concept of reliability-centered maintenance, this paper proposes a preventive maintenance strategy that can be implemented in real power systems due to the limited data requirements. The priority of each line for preventive maintenance was obtained by two indices revealing the technical condition and importance of each line in the network. The proposed method was applied to a real transmission network in Khorasan province of Iran. In order to extract the condition index of lines, failure statistics during six recent years as well as technical data of lines were investigated. Moreover, this paper presents a two-stage method to determine the importance index of each line by evaluating the consequences of line failures on the network. The presented results show the efficiency of the proposed approach.
- 8 December 2022
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-11
Open AccessReliability-Centered Maintenance for Overhead Transmission Lines in Composite Power System
Reliable overhead transmission lines have a vital role in maintaining the reliability of power systems at a desirable level and ensuring the continuity of electrical energy. In this regard, a proper preventive maintenance program can ensure the reliable functioning of transmission lines. Based on the concept of reliability-centered maintenance, this paper proposes a preventive maintenance strategy that can be implemented in real power systems due to the limited data requirements. The priority of each line for preventive maintenance was obtained by two indices revealing the technical condition and importance of each line in the network. The proposed method was applied to a real transmission network in Khorasan province of Iran. In order to extract the condition index of lines, failure statistics during six recent years as well as technical data of lines were investigated. Moreover, this paper presents a two-stage method to determine the importance index of each line by evaluating the consequences of line failures on the network. The presented results show the efficiency of the proposed approach.
- Open Access
- 18 July 2022
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-17
Power Swing and Fault Detection in the Presence of Wind Farms Using Generator Speed Zero-Crossing Moment
Nowadays, due to the entry of wind power plants into the power systems, which causes changes in the network parameters, power swing detection has become more important. Changes in the wind speed and noncontinuity of the wind power plants lead to changes in the power swing characteristic. Therefore, the impedance seen by the distance relay is changed, and so the maloperation of the relay during the stable power swing may occur. This paper proposes a new method to detect power fluctuations based on the synchronous generator speed while it is independent of the network parameters. Based on the proposed method, the generator speed at any moment does not pass through zero during the stable power swing. In contrast, it passes through zero by occurring fault types with high and low fault resistance, fault types during power swing, and an unstable power swing. Therefore, the method prevents maloperation of distance protection. It is worth noting that the proposed method is applicable for distance protection in any power system with and without wind power plants, such as in the distance protection of compensated transmission lines. The obtained results indicate that the proposed method detects power fluctuations in a short time.
- 18 July 2022
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-17
Open AccessPower Swing and Fault Detection in the Presence of Wind Farms Using Generator Speed Zero-Crossing Moment
Nowadays, due to the entry of wind power plants into the power systems, which causes changes in the network parameters, power swing detection has become more important. Changes in the wind speed and noncontinuity of the wind power plants lead to changes in the power swing characteristic. Therefore, the impedance seen by the distance relay is changed, and so the maloperation of the relay during the stable power swing may occur. This paper proposes a new method to detect power fluctuations based on the synchronous generator speed while it is independent of the network parameters. Based on the proposed method, the generator speed at any moment does not pass through zero during the stable power swing. In contrast, it passes through zero by occurring fault types with high and low fault resistance, fault types during power swing, and an unstable power swing. Therefore, the method prevents maloperation of distance protection. It is worth noting that the proposed method is applicable for distance protection in any power system with and without wind power plants, such as in the distance protection of compensated transmission lines. The obtained results indicate that the proposed method detects power fluctuations in a short time.