High spatial resolution spiral first‐pass myocardial perfusion imaging with whole‐heart coverage at 3 T
- 11 March 2021
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (2) , 648-662
Abstract
Purpose: To develop and evaluate a high spatial resolution (1.25 × 1.25 mm2) spiral first‐pass myocardial perfusion imaging technique with whole‐heart coverage at 3T, to better assess transmural differences in perfusion between the endocardium and epicardium, to quantify the myocardial ischemic burden, and to improve the detection of obstructive coronary artery disease.Methods: Whole‐heart high‐resolution spiral perfusion pulse sequences and corresponding motion‐compensated reconstruction techniques for both interleaved single‐slice (SS) and simultaneous multi‐slice (SMS) acquisition with or without outer‐volume suppression (OVS) were developed. The proposed techniques were evaluated in 34 healthy volunteers and 8 patients (55 data sets). SS and SMS images were reconstructed using motion‐compensated L1‐SPIRiT and SMS‐Slice‐L1‐SPIRiT, respectively. Images were blindly graded by 2 experienced cardiologists on a 5‐point scale (5, excellent; 1, poor).Results: High‐quality perfusion imaging was achieved for both SS and SMS acquisitions with or without OVS. The SS technique without OVS had the highest scores (4.5 [4, 5]), which were greater than scores for SS with OVS (3.5 [3.25, 3.75], P < .05), MB = 2 without OVS (3.75 [3.25, 4], P < .05), and MB = 2 with OVS (3.75 [2.75, 4], P < .05), but significantly higher than those for MB = 3 without OVS (4 [4, 4], P = .95). SMS image quality was improved using SMS‐Slice‐L1‐SPIRiT as compared to SMS‐L1‐SPIRiT (P < .05 for both reviewers).Conclusion: We demonstrated the successful implementation of whole‐heart spiral perfusion imaging with high resolution at 3T. Good image quality was achieved, and the SS without OVS showed the best image quality. Evaluation in patients with expected ischemic heart disease is warranted.Keywords
Funding Information
- National Institutes of Health (R01 HL131919, R01 NIH HL147104)
This publication has 47 references indexed in Scilit:
- Reduced field of view single‐shot spiral perfusion imagingMagnetic Resonance in Medicine, 2017
- First‐pass myocardial perfusion imaging with whole‐heart coverage using L1‐SPIRiT accelerated variable density spiral trajectoriesMagnetic Resonance in Medicine, 2015
- Towards elimination of the dark-rim artifact in first-pass myocardial perfusion MRI: Removing Gibbs ringing effects using optimized radial imagingMagnetic Resonance in Medicine, 2013
- Prognostic Value of Stress Cardiac Magnetic Resonance Imaging in Patients With Known or Suspected Coronary Artery DiseaseJACC, 2013
- Improved first‐pass spiral myocardial perfusion imaging with variable density trajectoriesMagnetic Resonance in Medicine, 2012
- Diagnostic Performance of Noninvasive Myocardial Perfusion Imaging Using Single-Photon Emission Computed Tomography, Cardiac Magnetic Resonance, and Positron Emission Tomography Imaging for the Detection of Obstructive Coronary Artery DiseaseJACC, 2012
- Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trialThe Lancet, 2012
- Optimization of spiral‐based pulse sequences for first‐pass myocardial perfusion imagingMagnetic Resonance in Medicine, 2011
- Noninvasive Assessment of Myocardial PerfusionCirculation: Cardiovascular Imaging, 2009
- Acquisition and reconstruction of undersampled radial data for myocardial perfusion magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2009