Abstract
The aim of this retrospective study was to evaluate the cumulative survival rate of tapered implant with a sandblasted and acid-etched surface placed in edentulous patients. A retrospective study was performed by evaluating MIS seven implants consecutively placed from December 2004 to January 2008. Patient records were reviewed to determine gender, age at implant placement, implant location, prosthesis type, marginal bone loss according to treatment procedure, number of implants, and number of failed implants. The survival rate of the implants was analyzed, and radiographic evaluation was performed. A total of 294 implants were placed in 92 patients at the 3 centers. The observation period after implantation ranged from 22 to 59 months, with a mean of 38 months. The cumulative survival rate of MIS seven implants was 97.3%. After 1 year of functional loading, the mean marginal bone loss was 0.33 mm. This retrospective, multicenter study demonstrates that this dental implant system gives clinically reliable results.Keywords
This publication has 22 references indexed in Scilit:
- A rough surface implant neck with microthreads reduces the amount of marginal bone loss: a prospective clinical studyClinical Oral Implants Research, 2009
- New Bone Formation in the Maxillary Sinus Without Bone GraftsImplant Dentistry, 2008
- A 10‐year prospective study of ITI dental implants placed in the posterior region. I: Clinical and radiographic resultsClinical Oral Implants Research, 2007
- Significance of primary stability for osseointegration of dental implantsClinical Oral Implants Research, 2006
- One‐Year Results of a Prospective Multicenter Study on Brånemark System® Implants with a TiUnite™ SurfaceClinical Implant Dentistry and Related Research, 2005
- Influence of implant taper on the primary and secondary stability of osseointegrated titanium implantsClinical Oral Implants Research, 2004
- Brånemark System® and ITI Dental Implant System® for treatment of mandibular edentulismClinical Oral Implants Research, 2001
- A 5‐year prospective clinical and radiographic study of non‐submerged dental implantsClinical Oral Implants Research, 2000
- Osseointegrated Oral ImplantsJournal of Periodontology, 1988
- Osseointegrated Titanium Implants:Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Anchorage in ManActa Orthopaedica, 1981