Harmonic Multiple Loop Detection (HMLD) Algorithm for Not-Contact Vital Sign Monitoring Based on Ultra-Wideband (UWB) Radar
Open Access
- 24 February 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 38786-38793
Abstract
In this paper, the harmonic multiple loop detection (HMLD) algorithm for heart rate (HR) and respiration rate (RR) estimation with impulse radio ultrawideband (IR-UWB) radar is introduced. The algorithm includes two parts: one is the harmonic multiple discriminant principle and the other is the cyclic spectrum updating process. The harmonic multiple discriminant principle is used to detect whether the peak point in the fundamental frequency band is the true vital sign signal. The cyclic spectrum updating process can remove the error peak point according to the results obtained from the part one. In this algorithm, threshold setting is not needed and the estimation error caused by the erroneous threshold can be reduced. Only the fundamental and second harmonic frequencies are needed for HR and RR estimation, so the algorithm has strong environmental robustness and low requirement of radar hardwares. Compared with other algorithms, HMLD algorithm provides reasonable average error rates (4.95% and 5.06%) compared to real data from the oximeter in RR and HR detection. The real-time vital signs detection experiment shows that HMLD algorithm can not only detect the vital signs rate and record the historical curve in real time, but also detect the location information, which proves the validity of HMLD algorithm in real-time vital signs detection.Keywords
This publication has 36 references indexed in Scilit:
- Remote monitoring of vital signs using a CMOS UWB radar transceiver2016
- Phase-Based Methods for Heart Rate Detection Using UWB Impulse Doppler RadarIEEE Transactions on Microwave Theory and Techniques, 2016
- Fast Acquisition of Heart Rate in Noncontact Vital Sign Radar Measurement Using Time-Window-Variation TechniqueIEEE Transactions on Instrumentation and Measurement, 2015
- Noncontact Multiple Heartbeats Detection and Subject Localization Using UWB Impulse Doppler RadarIEEE Microwave and Wireless Components Letters, 2015
- Estimation of Respiratory Rate From Photoplethysmographic Imaging Videos Compared to Pulse OximetryIEEE Journal of Biomedical and Health Informatics, 2015
- Spectrum-averaged Harmonic Path (SHAPA) algorithm for non-contact vital sign monitoring with ultra-wideband (UWB) radar2014
- Eulerian video magnification for revealing subtle changes in the worldACM Transactions on Graphics, 2012
- Vital SignsAJN, American Journal of Nursing, 2010
- ANALYSIS OF VITAL SIGNS MONITORING USING AN IR-UWB RADARProgress In Electromagnetics Research, 2010
- UWB radars in medicineIEEE Aerospace and Electronic Systems Magazine, 2002