Hemocompatibility and Hemodynamics of Novel Hyaluronan–Polyethylene Materials for Flexible Heart Valve Leaflets
- 20 November 2013
- journal article
- research article
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 5 (1) , 70-81
Abstract
Polymeric heart valves (PHVs) hold the promise to be more durable than bioprosthetic heart valves and less thrombogenic than mechanical heart valves. We introduce a new framework to manufacture hemocompatible polymeric leaflets for HV (PHV) applications using a novel material comprised of interpenetrating networks (IPNs) of hyaluronan (HA) and linear low density polyethylene (LLDPE). We establish and characterize the feasibility of the material as a substitute leaflet material through basic hemodynamic measurements in a trileaflet configuration, in addition to demonstrating superior platelet response and clotting characteristics. Plain LLDPE sheets were swollen in a solution of silylated-HA, the silylated-HA was then crosslinked to itself before it was reverted back to native HA via hydrolysis. Leaflets were characterized with respect to (1) bending stiffness, (2) hydrophilicity, (3) whole blood clotting, and (4) cell (platelet and leukocyte) adhesion under static conditions using fresh human blood. In vitro hemodynamic testing of prototype HA/LLDPE IPN PHVs was used to assess feasibility as functional HVs. Bending stiffness was not significantly different from natural fresh leaflets. HA/LLDPE IPNs were more hydrophilic than LLDPE controls. HA/LLDPE IPNs caused less whole blood clotting and reduced cell adhesion compared to the plain LLDPE control. Prototype PHVs made with HA/LLDPE IPNs demonstrated an acceptable regurgitation fraction of 4.77 ± 0.42%, and effective orifice area in the range 2.34 ± 0.5 cm2. These results demonstrate strong potential for IPNs between HA and polymers as future hemocompatible HV leaflets. Further studies are necessary to assess durability and calcification resistance.Keywords
This publication has 38 references indexed in Scilit:
- The anti-calcification potential of a silsesquioxane nanocomposite polymer under in vitro conditions: Potential material for synthetic leaflet heart valve☆Acta Biomaterialia, 2010
- Prosthetic aortic heart valves: Modeling and designMedical Engineering & Physics, 2010
- Engineering Nanoassemblies of PolysaccharidesAdvanced Materials, 2010
- A novel nanocomposite polymer for development of synthetic heart valve leafletsActa Biomaterialia, 2009
- FLUID MECHANICS OF ARTIFICIAL HEART VALVESClinical and Experimental Pharmacology and Physiology, 2009
- Heart valve function: a biomechanical perspectivePhilosophical Transactions of the Royal Society B: Biological Sciences, 2007
- Spatio-temporal Flow Analysis in Bileaflet Heart Valve Hinge Regions: Potential Analysis for Blood Element DamageAnnals of Biomedical Engineering, 2007
- Fluid Dynamic Assessment of Three Polymeric Heart Valves Using Particle Image VelocimetryAnnals of Biomedical Engineering, 2006
- Bioprosthetic tissue preservation by filling with a poly(acrylamide) hydrogelBiomaterials, 2006
- International Cardiac SurgerySeminars in Thoracic and Cardiovascular Surgery, 2002