Aa Susan James
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aa Susan James has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Ketul Chandrakant Popat
Department of Bioengineering George Mason University Fairfax Virginia USA
4 shared publications Min Zhang
University of Washington, Seattle, Washington
3 shared publicationsDavid A. Prawel
Department of Mechanical Engineering, Colorado State University, Fort Collins, USA
2 shared publications- Hieu T. Bui
School of Biomedical Engineering, Colorado State University, Fort Collins, CO, USA
2 shared publications Lakshmi Prasad Dasi
Department of Biomedical Engineering
2 shared publications- Melissa M. Reynolds
Department of Chemistry, Colorado State University, 301 W. Pitkin, Chemistry Research Building, Fort Collins, Colorado, 80521, USA
2 shared publications
Latest Publications
- 30 April 2025
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 11 (5) , 3058-3070
Polymeric Heart Valve Leaflets Tested in an Accelerated Wear Tester Revealed a Stable Craze Microstructure
Rheumatic and calcified aortic heart valve disease is a global health concern, impacting millions of individuals across various age groups. The gold standard medical treatments recommend replacing the sick heart valves with bioprosthetic valves that are chemically fixed using glutaraldehyde, commonly sourced from bovines or porcines. Clinical investigations over more than two decades have revealed that fixed tissues are prone to premature calcification and tearing, thereby limiting their durability. An innovative alternative approach involves biomolecule-enhanced polyethylene-based linear low-density polyethylene. LLDPE thin films have high tear strength and excellent flexibility, making them an appealing choice for developing heart valves. Nonetheless, during durability testing according to the ISO 5840-2005 standards, these leaflets exhibited premature failure. The leaflets consistently wear and tear around highly stressed commissure posts. Nine of these worn leaflets were retrieved from the failed valves and chemically etched. The semicrystalline LLDPE polymer underwent chemical etching using a standard 2% w/v permanganate etching solution, followed by multistep washing. SEM analysis of virgin LLDPE unveiled distinctive spherulitic structures consisting of well-organized lamellae with diameters of approximately 3 μm and dimensions below 100 nm. The etching process effectively eliminated low-energy amorphous regions, revealing the spherulites. A similar study was carried out on the damaged leaflets. The SEM images displayed signs of surface wear and aligned areas of polymeric material oriented perpendicular to the principal stress direction. Following etching, some of the built-up remained partially intact, while other areas exposed the crystals beneath them. Remarkably, one of the worn samples unveiled the Kramer craze microstructure "cross-tie" composed of aligned fibrils and interlinked fibrils. The spacing between cross-tie lamella ranges between 100 and 200 nm and the thickness remains at 40-80 nm. To the best of the author's knowledge, a cross-tie structure has only been theorized with indirect evidence collected from laboratory-grown crazes. These findings are further confirmed with SAXS.
- 30 April 2025
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 11 (5) , 3058-3070
Polymeric Heart Valve Leaflets Tested in an Accelerated Wear Tester Revealed a Stable Craze Microstructure
Rheumatic and calcified aortic heart valve disease is a global health concern, impacting millions of individuals across various age groups. The gold standard medical treatments recommend replacing the sick heart valves with bioprosthetic valves that are chemically fixed using glutaraldehyde, commonly sourced from bovines or porcines. Clinical investigations over more than two decades have revealed that fixed tissues are prone to premature calcification and tearing, thereby limiting their durability. An innovative alternative approach involves biomolecule-enhanced polyethylene-based linear low-density polyethylene. LLDPE thin films have high tear strength and excellent flexibility, making them an appealing choice for developing heart valves. Nonetheless, during durability testing according to the ISO 5840-2005 standards, these leaflets exhibited premature failure. The leaflets consistently wear and tear around highly stressed commissure posts. Nine of these worn leaflets were retrieved from the failed valves and chemically etched. The semicrystalline LLDPE polymer underwent chemical etching using a standard 2% w/v permanganate etching solution, followed by multistep washing. SEM analysis of virgin LLDPE unveiled distinctive spherulitic structures consisting of well-organized lamellae with diameters of approximately 3 μm and dimensions below 100 nm. The etching process effectively eliminated low-energy amorphous regions, revealing the spherulites. A similar study was carried out on the damaged leaflets. The SEM images displayed signs of surface wear and aligned areas of polymeric material oriented perpendicular to the principal stress direction. Following etching, some of the built-up remained partially intact, while other areas exposed the crystals beneath them. Remarkably, one of the worn samples unveiled the Kramer craze microstructure "cross-tie" composed of aligned fibrils and interlinked fibrils. The spacing between cross-tie lamella ranges between 100 and 200 nm and the thickness remains at 40-80 nm. To the best of the author's knowledge, a cross-tie structure has only been theorized with indirect evidence collected from laboratory-grown crazes. These findings are further confirmed with SAXS.
- 2 January 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 163, 106884
Parametric finite element modeling of reinforced polymeric leaflets for improved durability
- 2 January 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 163, 106884
Parametric finite element modeling of reinforced polymeric leaflets for improved durability
- Open Access
- 31 December 2022
- Published by Iowa State University
- Vol. 79 (1)
Surface Treatment of Non-woven Polypropylene Used in Personal Protective Equipment to Reduce SARS-CoV-2 Spread
- 31 December 2022
- Published by Iowa State University
- Vol. 79 (1)
Open AccessSurface Treatment of Non-woven Polypropylene Used in Personal Protective Equipment to Reduce SARS-CoV-2 Spread
- 12 September 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 135, 105434
Design consideration of a novel polymeric transcatheter heart valve through computational modeling
- 12 September 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 135, 105434
Design consideration of a novel polymeric transcatheter heart valve through computational modeling
- Open Access
- 25 August 2022
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 3 (20) , 7501-7507
Treatment of nonwoven polypropylene to increase adsorption of SARS-CoV-2 spike protein
Two techniques for increasing adsorption of SARS-CoV-2 spike protein to nonwoven polypropylene used in over-the-counter face masks.
- 25 August 2022
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 3 (20) , 7501-7507
Open AccessTreatment of nonwoven polypropylene to increase adsorption of SARS-CoV-2 spike protein
Two techniques for increasing adsorption of SARS-CoV-2 spike protein to nonwoven polypropylene used in over-the-counter face masks.
- 1 March 2022
- Published by Weston Medical Publishing in Journal of Emergency Management
- Vol. 20 (7) , 71-76
Innovative public health staff augmentation concepts during a global pandemic
At the onset of the COVID-19 global pandemic, Florida’s State Emergency Response Team’s Emergency Support Function 8 (ESF-8) Health and Medical Staffing Unit faced a surge of personnel requests from the field. The unit found that, given the scope of requests, standard disaster staffing practices could not always accommodate the requirements of the requests. With full support of leadership, the ESF-8 Staffing Unit developed new and innovative practices to streamline the cumbersome hiring process including coordinating with internal and external partners to expedite staff identification and implementing just-in-time training.
- 1 March 2022
- Published by Weston Medical Publishing in Journal of Emergency Management
- Vol. 20 (7) , 71-76
Innovative public health staff augmentation concepts during a global pandemic
At the onset of the COVID-19 global pandemic, Florida’s State Emergency Response Team’s Emergency Support Function 8 (ESF-8) Health and Medical Staffing Unit faced a surge of personnel requests from the field. The unit found that, given the scope of requests, standard disaster staffing practices could not always accommodate the requirements of the requests. With full support of leadership, the ESF-8 Staffing Unit developed new and innovative practices to streamline the cumbersome hiring process including coordinating with internal and external partners to expedite staff identification and implementing just-in-time training.
- 22 November 2019
- Published by Springer Nature in Journal of Materials Science
- Vol. 55 (8) , 3668-3683
Master sintering curves of nickel-titanium and nickel-titanium open-cell foams fabricated by spark plasma sintering
- 22 November 2019
- Published by Springer Nature in Journal of Materials Science
- Vol. 55 (8) , 3668-3683
Master sintering curves of nickel-titanium and nickel-titanium open-cell foams fabricated by spark plasma sintering
- 7 May 2019
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (21) , 18930-18941
Development and Fabrication of Vapor Cross-Linked Hyaluronan–Polyethylene Interpenetrating Polymer Network as a Biomaterial
Flexible heart valve leaflets made from hyaluronan enhanced linear low-density polyethylene interpenetrating polymeric network (HA-LLDPE IPN) films have been shown to provide good hemodynamics, but the resulting surfaces were not consistent; therefore, the present work tries to mitigate this problem by developing a vapor crosslinked HA-LLDPE IPN. Herein, the HA-LLDPE fabrication process is studied, and its parameters are varied to assess their effects on the IPN formation. Thermal analysis and gas chromatography-mass spectrometry were used to quantify the effects of different treatment conditions on material properties. Water contact angle goniometry, infrared spectroscopy, and toluidine blue O (TBO) staining were used to characterize the surface of the HA-LLDPE IPN. The results show a hydrophilic surface is formed on HA-LLDPE, which is indicative of HA. HA surface density data from TBO staining show consistent HA distribution on the surface. The IPN fabrication process does not affect the tensile properties that make LLDPE an attractive material for use in flexible heart valve leaflets. The 28-day in vitro biological assays show HA-LLDPE to be non-cytotoxic and resistant to enzymatic degradation. The HA-LLDPE showed less platelet adhesion and caused less platelet activation than the plain LLDPE or tissue culture polystyrene. All the results indicate that vapor crosslinked HA-LLDPE IPN is a promising material to use as flexible leaflets for heart valve replacements.
- 7 May 2019
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (21) , 18930-18941
Development and Fabrication of Vapor Cross-Linked Hyaluronan–Polyethylene Interpenetrating Polymer Network as a Biomaterial
Flexible heart valve leaflets made from hyaluronan enhanced linear low-density polyethylene interpenetrating polymeric network (HA-LLDPE IPN) films have been shown to provide good hemodynamics, but the resulting surfaces were not consistent; therefore, the present work tries to mitigate this problem by developing a vapor crosslinked HA-LLDPE IPN. Herein, the HA-LLDPE fabrication process is studied, and its parameters are varied to assess their effects on the IPN formation. Thermal analysis and gas chromatography-mass spectrometry were used to quantify the effects of different treatment conditions on material properties. Water contact angle goniometry, infrared spectroscopy, and toluidine blue O (TBO) staining were used to characterize the surface of the HA-LLDPE IPN. The results show a hydrophilic surface is formed on HA-LLDPE, which is indicative of HA. HA surface density data from TBO staining show consistent HA distribution on the surface. The IPN fabrication process does not affect the tensile properties that make LLDPE an attractive material for use in flexible heart valve leaflets. The 28-day in vitro biological assays show HA-LLDPE to be non-cytotoxic and resistant to enzymatic degradation. The HA-LLDPE showed less platelet adhesion and caused less platelet activation than the plain LLDPE or tissue culture polystyrene. All the results indicate that vapor crosslinked HA-LLDPE IPN is a promising material to use as flexible leaflets for heart valve replacements.
- 20 November 2013
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 5 (1) , 70-81
Hemocompatibility and Hemodynamics of Novel Hyaluronan–Polyethylene Materials for Flexible Heart Valve Leaflets
Polymeric heart valves (PHVs) hold the promise to be more durable than bioprosthetic heart valves and less thrombogenic than mechanical heart valves. We introduce a new framework to manufacture hemocompatible polymeric leaflets for HV (PHV) applications using a novel material comprised of interpenetrating networks (IPNs) of hyaluronan (HA) and linear low density polyethylene (LLDPE). We establish and characterize the feasibility of the material as a substitute leaflet material through basic hemodynamic measurements in a trileaflet configuration, in addition to demonstrating superior platelet response and clotting characteristics. Plain LLDPE sheets were swollen in a solution of silylated-HA, the silylated-HA was then crosslinked to itself before it was reverted back to native HA via hydrolysis. Leaflets were characterized with respect to (1) bending stiffness, (2) hydrophilicity, (3) whole blood clotting, and (4) cell (platelet and leukocyte) adhesion under static conditions using fresh human blood. In vitro hemodynamic testing of prototype HA/LLDPE IPN PHVs was used to assess feasibility as functional HVs. Bending stiffness was not significantly different from natural fresh leaflets. HA/LLDPE IPNs were more hydrophilic than LLDPE controls. HA/LLDPE IPNs caused less whole blood clotting and reduced cell adhesion compared to the plain LLDPE control. Prototype PHVs made with HA/LLDPE IPNs demonstrated an acceptable regurgitation fraction of 4.77 ± 0.42%, and effective orifice area in the range 2.34 ± 0.5 cm2. These results demonstrate strong potential for IPNs between HA and polymers as future hemocompatible HV leaflets. Further studies are necessary to assess durability and calcification resistance.
- 20 November 2013
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 5 (1) , 70-81
Hemocompatibility and Hemodynamics of Novel Hyaluronan–Polyethylene Materials for Flexible Heart Valve Leaflets
Polymeric heart valves (PHVs) hold the promise to be more durable than bioprosthetic heart valves and less thrombogenic than mechanical heart valves. We introduce a new framework to manufacture hemocompatible polymeric leaflets for HV (PHV) applications using a novel material comprised of interpenetrating networks (IPNs) of hyaluronan (HA) and linear low density polyethylene (LLDPE). We establish and characterize the feasibility of the material as a substitute leaflet material through basic hemodynamic measurements in a trileaflet configuration, in addition to demonstrating superior platelet response and clotting characteristics. Plain LLDPE sheets were swollen in a solution of silylated-HA, the silylated-HA was then crosslinked to itself before it was reverted back to native HA via hydrolysis. Leaflets were characterized with respect to (1) bending stiffness, (2) hydrophilicity, (3) whole blood clotting, and (4) cell (platelet and leukocyte) adhesion under static conditions using fresh human blood. In vitro hemodynamic testing of prototype HA/LLDPE IPN PHVs was used to assess feasibility as functional HVs. Bending stiffness was not significantly different from natural fresh leaflets. HA/LLDPE IPNs were more hydrophilic than LLDPE controls. HA/LLDPE IPNs caused less whole blood clotting and reduced cell adhesion compared to the plain LLDPE control. Prototype PHVs made with HA/LLDPE IPNs demonstrated an acceptable regurgitation fraction of 4.77 ± 0.42%, and effective orifice area in the range 2.34 ± 0.5 cm2. These results demonstrate strong potential for IPNs between HA and polymers as future hemocompatible HV leaflets. Further studies are necessary to assess durability and calcification resistance.
- 1 April 2013
- Published by Elsevier in Materials Letters
- Vol. 97, 81-85
Electrohydrodynamic atomization technique for applying phospholipid coatings to titanium implant materials
- 1 April 2013
- Published by Elsevier in Materials Letters
- Vol. 97, 81-85
Electrohydrodynamic atomization technique for applying phospholipid coatings to titanium implant materials