Diagnosis of Ruptured Breast Implants Through High-Resolution Ultrasound Combined With Real-Time Elastography
Open Access
- 24 March 2015
- journal article
- Published by Oxford University Press (OUP) in Aesthetic Surgery Journal
- Vol. 35 (4) , 410-418
Abstract
Implant rupture as a late complication of breast implant surgery is often a silent phenomenon that is difficult to diagnose. Sonoelastography is a new ultrasound-based technique that allows assessment of tissue elasticity. This study was undertaken to evaluate elastographic findings in normal and ruptured breast implants. This prospective study included 28 implants in 16 patients, all of whom underwent high-resolution ultrasound and real-time elastography. The diagnosis of implant rupture was confirmed by surgery. Implant rupture was diagnosed in 5 out of 28 implants (17.9%). In those patients with ruptured implants, 3 had no symptoms, 1 presented with pain, and 1 complained of ipsilateral axillary lymph node swelling. Implants with a homogenous anechoic interior were considered to be intact. Ultrasound findings indicating implant rupture included multiple parallel echogenic lines in the implant interior in 2 cases and a mix of hyperechoic and hypoechoic masses in 3 cases. The feasibility of real-time elastography of implants was demonstrated in all cases. Elastograms of intact implants revealed a typical blue-green-red pattern familiar from cystic lesions. In all 5 ruptured implants, elastography revealed yellow-green figures without typical layering. To the authors’ knowledge this is the first series to combine high-resolution ultrasound with real-time elastography for the diagnosis of implant rupture. Since there are distinct differences between elastograms of intact and ruptured implants, addition of real-time elastography to conventional ultrasound may improve implant surveillance and obviate the need for magnetic resonance imaging. 3 TherapeuticKeywords
This publication has 25 references indexed in Scilit:
- Cosmetic Surgery National Data Bank: Statistics 2013Aesthetic Surgery Journal, 2014
- The sonographic appearances of breast implant ruptureClinical Radiology, 2013
- High-Resolution Ultrasound in the Detection of Silicone Gel Breast Implant Shell Failure: Background, In Vitro Studies, and Early Clinical ResultsAesthetic Surgery Journal, 2012
- Ultrasonographic differentiation of malignant from benign breast lesions: a meta-analytic comparison of elasticity and BIRADS scoringBreast Cancer Research and Treatment, 2011
- The Utility of the "Bull's-Eye" Artifact on Breast Elasticity Imaging in Reducing Breast Lesion Biopsy RateUltrasound Quarterly, 2011
- The Effect of Study Design Biases on the Diagnostic Accuracy of Magnetic Resonance Imaging for Detecting Silicone Breast Implant Ruptures: A Meta-AnalysisPlastic and Reconstructive Surgery, 2011
- Comparative Study of Breast Implant Rupture Using Mammography, Sonography, and Magnetic Resonance Imaging: Correlation with Surgical FindingsThe Breast Journal, 2008
- Imaging and Estimation of Tissue Elasticity by UltrasoundUltrasound Quarterly, 2007
- Breast Disease: Clinical Application of US Elastography for DiagnosisRadiology, 2006
- Ultrasonographic Appearance of Breast Implant ComplicationsAnnals of Plastic Surgery, 2006