On Human Life Risk-Assessment and Sensitive Ground Fault Protection in MV Distribution Networks
Authors:
- 9 August 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 25 (4) , 2319-2327
Abstract
The minimum phase-to-ground fault current required to be sensed by protection systems in medium-voltage (MV) networks can be as low as 0.7 A in a few countries, leading to a lot of undesired relay trips and poor service quality to costumers. However, these settings raise the protection threshold above the minimum fault current that concerns network operators regarding human safety, although they cannot be practiced when grounding is distributed. The purpose of this paper is to present a risk assessment foundation to determine the required protection sensitivity to ensure human safety in MV distribution networks. The proposed approach is based on a biophysical model included in IEC standards, the consideration of current paths models for typical faults and Monte Carlo methods to deal with nonlinearity, and the many involved random variables. Downed conductors and line-to-concrete pole faults are investigated and sensitivity analysis performed to highlight some important determinants of the results.Keywords
This publication has 14 references indexed in Scilit:
- Arc Flash Hazard Calculations: Myths, Facts and Solutions2006
- Electrical injury: mechanisms, manifestations, and therapyIEEE Transactions on Dielectrics and Electrical Insulation, 2003
- Improved protection scheme for selective high resistance earth fault clearing in Slovenian distribution networks2003
- A method for detection and location of high resistance earth faults2002
- A review of techniques to detect downed conductors in overhead distribution systems2001
- Arcing fault detection for distribution feeders: security assessment in long term field trialsIEEE Transactions on Power Delivery, 1995
- Sensitive ground-fault relayingIEEE Transactions on Industry Applications, 1988
- New considerations on the threshold of ventricular fibrillation for a.c.shocks at 50–60 HzIEE Proceedings A Physical Science, Measurement and Instrumentation, Management and Education, Reviews, 1980
- Reevaluation of Lethal Electric CurrentsIEEE Transactions on Industry and General Applications, 1968
- Voltage Gradients Through the Ground under Fault ConditionsTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1958