The Influence of Different Speech Processor and Hearing Aid Settings on Speech Perception Outcomes in Electric Acoustic Stimulation Patients
- 1 January 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 29 (1) , 76-86
Abstract
Objective: Electric acoustic stimulation (EAS) is an increasingly popular means of treating individuals with a steeply sloping mid-to-high frequency hearing loss, who traditionally do not benefit from hearing instruments. These persons often have too much residual hearing to be considered for a cochlear implant. Several studies have demonstrated the ability both to preserve the remaining low-frequency hearing in these individuals, and to provide significant benefit through combining a cochlear implant with a hearing aid to amplify the same ear. These improvements in performance have been especially noted in noise. Often overlooked is that these outcomes may be influenced by the fitting parameters of both the cochlear implant and the hearing aid. Design: This study assessed four EAS subjects, with a minimum of 1 month's EAS use, on eight different fitting parameters. Sentence testing in different noise levels (+15, +10, and +5 dB SPL) was conducted. Subjects also evaluated each condition using a visual analogue scale. Results: Results demonstrated that a reduced overlap of cochlear implant and hearing aid amplification produced best results across listening conditions. Conclusions: The hearing aid should be fit to a patient-specific modified audiogram at least up to the point where low-frequency hearing is not measurable. The cochlear implant should be fit from a higher frequency point than is standard in patients without residual hearing in the implanted ear, to provide reduced overlap with the amplification provided by the hearing aid. Therefore, a small amount of overlap between the frequency ranges used by the hearing aid and the cochlear implant seems beneficial.Keywords
This publication has 17 references indexed in Scilit:
- Kochleaimplantat mit TieftonrestgehörerhaltHNO, 2005
- Combined Electric and Acoustic Stimulation of the Auditory System: Results of a Clinical StudyAudiology and Neurotology, 2005
- Preservation of residual hearing with cochlear implantation: How and whyActa Oto-Laryngologica, 2005
- Preservation of Hearing in Cochlear Implant Surgery: Advantages of Combined Electrical and Acoustical Speech ProcessingThe Laryngoscope, 2005
- Hearing preservation in cochlear implantation for electric acoustic stimulationActa Oto-Laryngologica, 2004
- Conservation of low-frequency hearing in cochlear implantationActa Oto-Laryngologica, 2004
- Combining acoustic and electrical hearingThe Laryngoscope, 2003
- Effects of low pass filtering on the intelligibility of speech in noise for people with and without dead regions at high frequenciesThe Journal of the Acoustical Society of America, 2002
- High-frequency audibility: Benefits for hearing-impaired listenersThe Journal of the Acoustical Society of America, 1998
- Speech recognition of hearing-impaired listeners: Predictions from audibility and the limited role of high-frequency amplificationThe Journal of the Acoustical Society of America, 1998