Katrien Vermeire
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Katrien Vermeire has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Paul Van de Heyning
Department of Otorhinolaryngology, Head and Neck Surgery, Antwerp University Hospital (UZA)
4 shared publications Ellen Cochet
2 shared publicationsAnouk Hofkens
1 shared publicationD De Ridder
1 shared publicationFloris L. Wuyts
1 shared publicationHilde Carpentier
Department of Otorhinolaryngology & Communication Disorders, University of Antwerp, Wilrijkstraat 10, 2650 Antwerp (Edegem), Belgium
1 shared publication
Latest Publications
- 1 January 2008
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 29 (1) , 76-86
The Influence of Different Speech Processor and Hearing Aid Settings on Speech Perception Outcomes in Electric Acoustic Stimulation Patients
Objective: Electric acoustic stimulation (EAS) is an increasingly popular means of treating individuals with a steeply sloping mid-to-high frequency hearing loss, who traditionally do not benefit from hearing instruments. These persons often have too much residual hearing to be considered for a cochlear implant. Several studies have demonstrated the ability both to preserve the remaining low-frequency hearing in these individuals, and to provide significant benefit through combining a cochlear implant with a hearing aid to amplify the same ear. These improvements in performance have been especially noted in noise. Often overlooked is that these outcomes may be influenced by the fitting parameters of both the cochlear implant and the hearing aid. Design: This study assessed four EAS subjects, with a minimum of 1 month's EAS use, on eight different fitting parameters. Sentence testing in different noise levels (+15, +10, and +5 dB SPL) was conducted. Subjects also evaluated each condition using a visual analogue scale. Results: Results demonstrated that a reduced overlap of cochlear implant and hearing aid amplification produced best results across listening conditions. Conclusions: The hearing aid should be fit to a patient-specific modified audiogram at least up to the point where low-frequency hearing is not measurable. The cochlear implant should be fit from a higher frequency point than is standard in patients without residual hearing in the implanted ear, to provide reduced overlap with the amplification provided by the hearing aid. Therefore, a small amount of overlap between the frequency ranges used by the hearing aid and the cochlear implant seems beneficial.
- 1 January 2008
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 29 (1) , 76-86
The Influence of Different Speech Processor and Hearing Aid Settings on Speech Perception Outcomes in Electric Acoustic Stimulation Patients
Objective: Electric acoustic stimulation (EAS) is an increasingly popular means of treating individuals with a steeply sloping mid-to-high frequency hearing loss, who traditionally do not benefit from hearing instruments. These persons often have too much residual hearing to be considered for a cochlear implant. Several studies have demonstrated the ability both to preserve the remaining low-frequency hearing in these individuals, and to provide significant benefit through combining a cochlear implant with a hearing aid to amplify the same ear. These improvements in performance have been especially noted in noise. Often overlooked is that these outcomes may be influenced by the fitting parameters of both the cochlear implant and the hearing aid. Design: This study assessed four EAS subjects, with a minimum of 1 month's EAS use, on eight different fitting parameters. Sentence testing in different noise levels (+15, +10, and +5 dB SPL) was conducted. Subjects also evaluated each condition using a visual analogue scale. Results: Results demonstrated that a reduced overlap of cochlear implant and hearing aid amplification produced best results across listening conditions. Conclusions: The hearing aid should be fit to a patient-specific modified audiogram at least up to the point where low-frequency hearing is not measurable. The cochlear implant should be fit from a higher frequency point than is standard in patients without residual hearing in the implanted ear, to provide reduced overlap with the amplification provided by the hearing aid. Therefore, a small amount of overlap between the frequency ranges used by the hearing aid and the cochlear implant seems beneficial.
- 1 January 2007
- p. 65-9
Phase-shift tinnitus treatment: an open prospective clinical trial.
We report on a novel treatment for tinnitus using phase-shift pure tone sound treatment in patients with predominantly pure tone tinnitus. Thirty-five patients with pure tone tinnitus unresponsive to all previous treatment were enrolled in the study. All patients were treated three times in one week. If the patient noticed an improvement, the therapy was continued for six weeks with a home device customised to their specific treatment frequency. Twenty-one of the 35 patients (60%) responded positively to the initial therapy sessions. Tinnitus was assessed before treatment, after three in-office Tinnitus Phase-Out System therapy sessions, and after six weeks of home use of the Patient Treatment Device. The assessment instruments were a VAS loudness scale and the quality of life Tinnitus Questionnaire. Significant tinnitus reduction was obtained on VAS after three office Tinnitus Phase-Out System therapy sessions (before treatment: mean VAS = 6.4; after three therapy sessions: mean VAS = 4.9; p = 0.042) and after six weeks of home use of the Patient Treatment Device (mean VAS = 4.9; p = 0.005). When analysing the mean TQ score over treatment, there was a significant improvement in total score from pretreatment (mean TQ score = 41.9) to six weeks after home use of the Patient Treatment Device use (mean TQ score = 36.4) (p = 0.003). In view of the results obtained, the Phase-Out Treatment for tinnitus may provide the majority of patients with a significant improvement in their symptoms. Further evaluation, comparing this specific Phase-Out Treatment with more general noise stimulation treatment, will further specify the indications for this treatment option.
- 1 January 2007
- p. 65-9
Phase-shift tinnitus treatment: an open prospective clinical trial.
We report on a novel treatment for tinnitus using phase-shift pure tone sound treatment in patients with predominantly pure tone tinnitus. Thirty-five patients with pure tone tinnitus unresponsive to all previous treatment were enrolled in the study. All patients were treated three times in one week. If the patient noticed an improvement, the therapy was continued for six weeks with a home device customised to their specific treatment frequency. Twenty-one of the 35 patients (60%) responded positively to the initial therapy sessions. Tinnitus was assessed before treatment, after three in-office Tinnitus Phase-Out System therapy sessions, and after six weeks of home use of the Patient Treatment Device. The assessment instruments were a VAS loudness scale and the quality of life Tinnitus Questionnaire. Significant tinnitus reduction was obtained on VAS after three office Tinnitus Phase-Out System therapy sessions (before treatment: mean VAS = 6.4; after three therapy sessions: mean VAS = 4.9; p = 0.042) and after six weeks of home use of the Patient Treatment Device (mean VAS = 4.9; p = 0.005). When analysing the mean TQ score over treatment, there was a significant improvement in total score from pretreatment (mean TQ score = 41.9) to six weeks after home use of the Patient Treatment Device use (mean TQ score = 36.4) (p = 0.003). In view of the results obtained, the Phase-Out Treatment for tinnitus may provide the majority of patients with a significant improvement in their symptoms. Further evaluation, comparing this specific Phase-Out Treatment with more general noise stimulation treatment, will further specify the indications for this treatment option.
- 1 March 2005
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 26 (2) , 188-195
Quality-of-Life Benefit from Cochlear Implantation in the Elderly
To compare the audiologic results of geriatric patients receiving cochlear implants with younger age groups and to evaluate the quality of life after cochlear implantation in the geriatric population by means of validated quality-of-life questionnaires. Cross-sectional study involving 89 postlingually deafened cochlear implant subjects. Tertiary referral center. A total of 89 postlingually deafened patients were included in the study, among which were 25 patients who were aged 70 years or older. All patients received a cochlear implant. Subjects were implanted with either the Laura, Nucleus 24, or Med-el Combi 40+ cochlear implant systems implementing the SPEAK, ACE, CIS, or CIS+ coding strategies. Speech recognition was determined by means of phonetically balanced monosyllabic word lists. The Hearing Handicap Inventory for Adults, the Glasgow Benefit Inventory, and the scale for the prediction of hearing disability in sensorineural hearing loss were used to quantify the quality of life. Mean audiologic performance for the three groups increased significantly after implantation (p < 0.001). Postoperative audiologic performance of the geriatric population led to useful hearing, but these scores were significantly lower than for the younger age groups (p = 0.002). However, the quality-of-life outcomes for the geriatric group were similar to those of the younger age groups (p = 0.411 for the Hearing Handicap Inventory for Adults; p = 0.886 for the Glasgow Benefit Inventory). The results of this study prove that cochlear implantation in the elderly provides improvements in quality of life and speech understanding, similar to those for younger adult cochlear implant recipients.
- 1 March 2005
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 26 (2) , 188-195
Quality-of-Life Benefit from Cochlear Implantation in the Elderly
To compare the audiologic results of geriatric patients receiving cochlear implants with younger age groups and to evaluate the quality of life after cochlear implantation in the geriatric population by means of validated quality-of-life questionnaires. Cross-sectional study involving 89 postlingually deafened cochlear implant subjects. Tertiary referral center. A total of 89 postlingually deafened patients were included in the study, among which were 25 patients who were aged 70 years or older. All patients received a cochlear implant. Subjects were implanted with either the Laura, Nucleus 24, or Med-el Combi 40+ cochlear implant systems implementing the SPEAK, ACE, CIS, or CIS+ coding strategies. Speech recognition was determined by means of phonetically balanced monosyllabic word lists. The Hearing Handicap Inventory for Adults, the Glasgow Benefit Inventory, and the scale for the prediction of hearing disability in sensorineural hearing loss were used to quantify the quality of life. Mean audiologic performance for the three groups increased significantly after implantation (p < 0.001). Postoperative audiologic performance of the geriatric population led to useful hearing, but these scores were significantly lower than for the younger age groups (p = 0.002). However, the quality-of-life outcomes for the geriatric group were similar to those of the younger age groups (p = 0.411 for the Hearing Handicap Inventory for Adults; p = 0.886 for the Glasgow Benefit Inventory). The results of this study prove that cochlear implantation in the elderly provides improvements in quality of life and speech understanding, similar to those for younger adult cochlear implant recipients.
- 10 January 2003
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 67 (1) , 67-70
Bilateral cochlear implantation in children
- 10 January 2003
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 67 (1) , 67-70
Bilateral cochlear implantation in children