Computational Characterization of Microwave Planar Cutoff Probes for Non-Invasive Electron Density Measurement in Low-Temperature Plasma: Ring- and Bar-Type Cutoff Probes
Open Access
- 12 October 2020
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 10 (20) , 7066
Abstract
The microwave planar cutoff probe, recently proposed by Kim et al. is designed to measure the cutoff frequency in a transmission (S21) spectrum. For real-time electron density measurement in plasma processing, three different types have been demonstrated: point-type, ring-type (RCP), and bar-type (BCP) planar cutoff probes. While Yeom et al. has shown that the RCP and BCP are more suitable than the point-type probe for process monitoring, the basic characteristics of the ring- and bar-type probes have yet to be investigated. The current work includes a computational characterization of a RCP and BCP with various geometrical parameters, as well as a plasma parameter, through a commercial three-dimensional electromagnetic simulation. The parameters of interest include antenna size, antenna distance, dielectric thickness of the transmission line, and input electron density. Simulation results showed that the RCP has several resonance frequencies originating from standing-wave resonance in the S21 spectrum that the BCP does not. Moreover, the S21 signal level increased with antenna size and dielectric thickness but decreased with antenna distance. Among the investigated parameters, antenna distance was found to be the most important parameter to improve the accuracy of both RCP and BCP.Keywords
Funding Information
- National Research Council of Science and Technology (CAP-17-02-NFRI)
- Korea Institute of Energy Technology Evaluation and Planning (20172010105910)
- Korea Institute for Advancement of Technology (P0008458)
- National Research Foundation of Korea (NRF-2020R1A6A1A03047771)
- the Defense Acquisition Program Administration and the Agency for Defense Development of Republic of Korea (the Aerospace Low Observable Technology Laboratory Program)
This publication has 22 references indexed in Scilit:
- Foundations of optical diagnostics in low-temperature plasmasPlasma Sources Science and Technology, 2020
- Advanced Process Control Using Virtual Metrology to Cope With Etcher Condition ChangeIEEE Transactions on Semiconductor Manufacturing, 2019
- A transmission line model of the cutoff probePlasma Sources Science and Technology, 2019
- Development of the Virtual Metrology for the Nitride Thickness in Multi-Layer Plasma-Enhanced Chemical Vapor Deposition Using Plasma-Information VariablesIEEE Transactions on Semiconductor Manufacturing, 2018
- The 2017 Plasma Roadmap: Low temperature plasma science and technologyJournal of Physics D: Applied Physics, 2017
- A simple and straightforward expression for curling probe electron density diagnosis in reactive plasmasPlasma Sources Science and Technology, 2017
- Measurement of electron density using reactance cutoff probePhysics of Plasmas, 2016
- Modeling Microwave Resonance of Curling Probe for Density Measurements in Reactive PlasmasApplied Physics Express, 2011
- Real-time In-situ Plasma Etch Process Monitoring for Sensor Based-Advanced Process ControlJOURNAL OF SEMICONDUCTOR TECHNOLOGY AND SCIENCE, 2011
- Wave cutoff method to measure absolute electron density in cold plasmaReview of Scientific Instruments, 2004