JKJung-Hyung Kim

Jung-Hyung Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jung-Hyung Kim has a total of 119 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Re-deposition and etching characteristics of plasma-exposed ceramics for semiconductor etching equipment

    by Seong-Hyeon Kim, Min Young Yoon, Hee-Jung Yeom, Sijun Kim, Gwang-Seok Chae, Wooram Kim, Chin-Wook Chung, Hyo-Chang Lee, Jung-Hyung Kim

  • Effects of transport loss on quadrupole mass spectrometer measurements in nitrogen plasmas

    by Min Young Yoon, Sijun Kim, Do-Yeon Hwang, Chan-Won Park, Gwang-Seok Chae, Eun-Seok Choe, Young-Gi Kim, Hee-Jung Yeom, Jung Hyung Kim, Hyo-Chang Lee

  • Effect of magnetic-field orientation on electron-density measurement using microwave cutoff probes in weakly magnetized plasma

    by Jae-Heon Lee, Do-Yeon Hwang, Gwang-Seok Chae, Min Young Yoon, Hee-Jung Yeom, Jung-Hyung Kim, Hyo-Chang Lee

    In this study, the wave transmission characteristics and cutoff-frequency shift of the microwave cutoff probes were investigated in weakly magnetized plasma using electromagnetic simulations and a magnetized equivalent circuit model. The external magnetic field was varied from 0 to 200 G, and the relative orientation of the electric field between the probe antennas was changed to examine its effect on cutoff-frequency. For the square cutoff probe, the cutoff frequency coincided with the input plasma frequency under parallel configuration, whereas it shifted toward the upper-hybrid resonance frequency under the perpendicular configuration due to electron cyclotron motion. This field-orientation-dependent shift was well described by the magnetized circuit model using the anisotropic dielectric tensor of magnetized plasma, with the electron-density discrepancy remaining within 2% under the parallel and perpendicular configurations and within 3% under oblique-field orientations. The cylindrical cutoff probe showed the same trend and demonstrated valid electron-density measurement capability, although a slightly increased discrepancy was observed under the perpendicular configuration, reaching up to 6%. Electric-field distribution analysis revealed that this difference originates from the more limited effective antenna-to-antenna field region in which the electric field is well aligned with the nominal configuration for the cylindrical probe. Misaligned field components near the antenna tip introduce additional deviation, which becomes more pronounced with increasing magnetic-field strength. Nevertheless, the discrepancy remained within acceptable levels across all investigated conditions, demonstrating that accurate electron-density measurement using microwave cutoff probes remains feasible in weakly magnetized plasma when the relative field orientation is properly considered.

  • Evolution of the electron energy probability function in Ar/SiH4 inductively coupled plasma

    by Seong-Hyeon Kim, Hee-Jung Yeom, Min Young Yoon, Yeong-Jae Jeong, Seong-Bin Park, Chin-Wook Chung, Jung-Hyung Kim, Hyo-Chang Lee

    We investigate the electron energy probability function (EEPF), electron density, and electron temperature in an Ar/SiH4 inductively coupled plasma (ICP) as a function of the SiH4 mixing ratio (RSiH4) using a Langmuir probe. A noticeable change in plasma behavior occurs around RSiH4=0.40: below this value, the EEPF remains approximately Maxwellian, while the effective electron temperature decreases gradually, whereas above it, the EEPF develops a non-Maxwellian distribution characterized by pronounced intermediate-energy depletion in the 3–6 eV range, accompanied by a sharp reduction in electron density. Measurement of the neutral species densities using a quadrupole mass spectrometer reveals that the discharge is dominated not by SiH4 but by its dissociation product H2, with Ar, H2, and H identified as the three principal neutral species. Weighting the inelastic cross sections by measured neutral densities reveals an enhanced H2-driven inelastic collision probability per unit path length in the 1–6 eV range, which closely overlaps with the energy region of the observed EEPF depletion, suggesting H2 as a plausible driver of the intermediate-energy electron loss. These results show that electron kinetics in an Ar/SiH4 ICP are governed by the discharge-phase neutral composition rather than the input gas mixture.

  • Suppressing structural resonance in ceramic-body microwave cutoff probes for reliable electron density measurement

    by Do-Yeon Hwang, Hee-Jung Yeom, Hye-Jin Ju, Wooram Kim, Hyo-Chang Lee, Jung-Hyung Kim

  • Laboratory-scale dual-pulse laser-produced plasma extreme ultraviolet source with continuous target replenishment using a tin-coated rotating disk

    by Do-Yeon Hwang, Wooram Kim, Seunghwoi Han, Eun-Seok Choe, Young-Gi Kim, Hyeok Yun, Seong-Pil Jo, Won Chegal, Sang-Woo Kang, Seungil Park, et al.

  • Analysis of the DC self-bias voltage in geometrically asymmetric capacitive discharges using global model simulations

    by Chan-Won Park, Hyo-Chang Lee, Shin-Jae You, Jung-Hyung Kim

    The DC self-bias voltage in geometrically asymmetric capacitive discharges is investigated as a function of RF power and argon gas pressure using experiments and a modified global-model analysis for a fixed reactor geometry. In the model, the grounded sidewall is treated separately from the grounded electrode, and the appropriate sheath description is selected by comparing the ion mean free path with the sheath width under each discharge condition. The analysis is constrained by measured voltage waveforms, absorbed power, harmonic content, and axial plasma-density profiles. The measured normalized DC self-bias voltage increases with RF power and exhibits a transition in pressure dependence over the investigated pressure range. The model-based analysis indicates that this transition can be interpreted in terms of changes in current partitioning between the powered electrode and grounded surfaces. Differences between the measured DC self-bias voltage and the simulated sheath-voltage ratio are attributed to harmonic distortion in the driving voltage waveform. These results provide an experimentally constrained framework for interpreting pressure-dependent DC self-bias behavior in asymmetric capacitive discharges.

  • Development of a Wafer-Embeddable Microwave Patch Antenna Sensor for Plasma Diagnostics in Semiconductor Processing

    by Gwang-Seok Chae, Hee-Jung Yeom, Min-Young Yoon, Eun-Seok Choe, Wooram Kim, Jung-Hyung Kim, Hyo-Chang Lee

    In this study, we present a microstrip-based microwave patch antenna sensor (MPAS) that can be embedded into a wafer to measure plasma on the wafer without bulky coaxial architectures. Modern high-volume manufacturing reactors employ narrow electrode–wafer gaps, and electrode-embedded diagnostics typically require redesign of electrodes that are already densely integrated with electrostatic clamping hardware, helium backside-gas delivery paths, and lift-pin through-holes. Conventional coaxial sensors further demand control of dielectric thickness, which complicates implementation in a wafer-thickness form factor. To address these constraints, the MPAS is implemented as a sub-mm flat antenna–dielectric–ground stack compatible with direct wafer integration while enabling cutoff-method-based measurement of the absolute electron density. We validate the effective sensing region on the wafer plane using electromagnetic simulations incorporating an intentionally nonuniform plasma model. Experiments show that the MPAS measures the electron density at the plasma−sheath boundary under the investigated conditions. Finally, an array-type MPAS is demonstrated to assess within-wafer uniformity, and spatially resolved electron-density distributions are compared with etch-rate trends. These results indicate that the MPAS is a promising diagnostic platform for wafer-level plasma monitoring and provides an effective foundation for developing next-generation plasma diagnostic tools.

  • Analysis of electron series resonance in lowpressure plasmas using a DC-biased cutoff probe

    by Chae Gwang-Seok, Chan-Won Park, Hee-Jung Yeom, Hyejin Ju, Hyo-Chang Lee, Jung-Hyung Kim

    Electron series resonance (ESR) can be interpreted as a series LC resonance between the inductive plasma and the capacitive sheaths. Depending on plasma characteristics, the ESR properties can shift with operating conditions. In prior studies, ESR was analyzed by varying external parameters such as input power, pressure, and electrode gap. However, these external parameters change not only the electron density but also other plasma parameters, such as the electron temperature. Therefore, an ESR analysis system capable of independently controlling these plasma parameters is needed. In this study, we developed an ESR analysis platform that can control the sheath thickness independently of other plasma parameters such as electron density, electron temperature, and pressure. A conventional cutoff probe consisting of the radiating and detecting antennas measures the absolute electron density. We confirmed through measured electron density and electron temperature that only the thickness of the biased sheath can be controlled by applying a DC bias voltage (V_DC) to one antenna of the cutoff probe, and observed the frequency trend of ESR frequency according to the sheath thickness. To analyze ESR characteristics according to sheath thickness, an equivalent circuit model was used. The circuit model's component values were calculated based on experimental results such as electron density, electron temperature, and discharge pressure. The observed ESR frequencies indicate an increase of the ESR frequency as |V_DC | increases, due to reduced sheath capacitance. The ESR frequency derived using the circuit model shows consistent results with the measured ESR frequency. These results enable a more detailed analysis of ESR characteristics under controlled plasma conditions and improve the accuracy of microwave cutoff–based diagnostics for determining plasma parameters, including electron temperature and electron density.

  • Plasma density measurement using phase-resolved optical emission spectroscopy in low-pressure capacitively coupled plasmas

    by Chan-Won Park, Julian Schulze, Birk Berger, Gwang-Seok Chae, Jung-Hyung Kim, Hyo-Chang Lee

    A new non-invasive optical diagnostic to measure the absolute and instantaneous electron density in low-pressure capacitive discharges by phase-resolved optical emission spectroscopy is presented. This optical approach provides nanosecond time-resolved insights into the dynamics of energetic electrons, specifically into multiple-electron beams launched into the plasma during a single phase of sheath expansion adjacent to an electrode. As the time interval between two consecutive beams corresponds to the inverse electron plasma frequency, the instantaneous electron plasma frequency, which corresponds to the electron density, can be measured by determining this time interval. The measured electron density is found to oscillate within a radio-frequency period at low-pressure discharge conditions. The dynamics of this density oscillation is analyzed using the continuity equation considering electron beams.