Specificity of a Circulating Antibody That Interferes With a Widely Used Tacrolimus Immunoassay
Authors:
- Bijal A ParikhBPBijal A Parikh
- Andrew M SiedleckiASAndrew M Siedlecki
- Mitchell G ScottMSMitchell G Scott
- 1 April 2010
- journal article
- case report
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
- Vol. 32 (2) , 228-231
Abstract
Accurate measurement of whole-blood tacrolimus concentration is essential for achieving therapeutic immunosuppression and minimizing toxicity in renal transplant recipients. Falsely elevated or decreased values may trigger unnecessary dose adjustments. We identified a falsely elevated whole-blood tacrolimus immunoassay result in a renal transplant patient. Twelve hours after the patient received his first dose, the blood concentration was 24.4 ng/mL using the Siemens Dimension RxL immunoassay. Immunoabsorption studies showed that the cause of the interference was an endogenous antibody present in the patient's plasma that recognized a unique epitope present on the antibody-enzyme (beta-galactosidase) conjugate used in the Siemens tacrolimus immunoassay but not on the antibody or beta-galactosidase alone. This report adds to the growing knowledge base of endogenous antibody interferences in diagnostic immunoassays. To our knowledge, this is the first such report of a falsely elevated tacrolimus concentration due to recognition of an epitope present only on the monoclonal antibody-enzyme conjugate.Keywords
This publication has 12 references indexed in Scilit:
- Heterophilic antibody interference in a non-endogenous molecule assay: An apparent elevation in the tacrolimus concentrationClinica Chimica Acta, 2009
- Falsely Increased Blood Tacrolimus Concentrations Using the ACMIA Assay Due to Circulating Endogenous Antibodies in a Liver Transplant Recipient: A Tentative Approach to Obtaining Reliable ResultsTherapeutic Drug Monitoring, 2009
- Immunosuppressive agents in solid organ transplantation: Mechanisms of action and therapeutic efficacyCritical Reviews in Oncology/Hematology, 2005
- Maintenance immunosuppression in the renal transplant recipient: An overviewAmerican Journal of Kidney Diseases, 2001
- IMx Tacrolimus II vs IMx Tacrolimus Microparticle Enzyme Immunoassay Evaluated in Renal and Hepatic Transplant PatientsClinical Chemistry, 1997
- Diabetes InsipidusEndocrinology and Metabolism Clinics of North America, 1995
- Interference by human anti-mouse antibody in two-site immunoassaysClinical Chemistry, 1990
- A simple method for the preparation of enzyme—antibody conjugatesFEBS Letters, 1978
- CLINICAL USE OF THE ANION GAPMedicine, 1977
- A comparative study of horseradish peroxidase conjugates prepared with a one-step and a two-step method.Journal of Histochemistry & Cytochemistry, 1975