Management of organ motion in scanned ion beam therapy
Open Access
- 6 November 2017
- journal article
- review article
- Published by Springer Nature in Radiation Oncology
- Vol. 12 (1) , 1-6
Abstract
Scanned ion beam therapy has special demands for treatment of intra-fractionally moving tumors such as lesions in lung or liver. Interplay effects between beam and organ motion can in those settings lead to under-dosage of the target volume. Dedicated treatment techniques such as gating or abdominal compression are required. In addition 4D treatment planning should be used to determine strategies for patient specific treatment planning such as an increased beam focus or the use of internal target volumes incorporating range changes. Several work packages of the Clinical Research Units 214 and 214/2 funded by the German Research Council investigated the management of organ motion in scanned ion beam therapy. A focus was laid on 4D treatment planning using TRiP4D and the development of motion mitigation strategies including their quality assurance. This review focuses on the activity in the second funding period covering adaptive treatment planning strategies, 4D treatment plan optimization, and the application of motion management in pre-clinical research on radiation therapy of cardiac arrhythmias.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (KFO 214/2, KFO 214/2)
This publication has 57 references indexed in Scilit:
- A patient-specific planning target volume used in 'plan of the day' adaptation for interfractional motion mitigationJournal of Radiation Research, 2013
- Adaptive radiotherapy based on the daily regression of a tumor in carbon-ion beam irradiationPhysics in Medicine & Biology, 2012
- Motion in radiotherapy: particle therapyPhysics in Medicine & Biology, 2011
- Introducing an on-line adaptive procedure for prostate image guided intensity modulate proton therapyPhysics in Medicine & Biology, 2011
- Phase i study evaluating the treatment of patients with hepatocellular carcinoma (HCC) with carbon ion radiotherapy: The PROMETHEUS-01 trialBMC Cancer, 2011
- Motion management with phase-adapted 4D-optimizationPhysics in Medicine & Biology, 2010
- 4D treatment planning for scanned ion beamsRadiation Oncology, 2007
- Simulations to design an online motion compensation system for scanned particle beamsPhysics in Medicine & Biology, 2006
- Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial FibrillationCirculation, 2005
- Effects of respiratory motion on dose uniformity with a charged particle scanning methodPhysics in Medicine & Biology, 1992