Three-dimensional ultrasound matrix imaging
Top Cited Papers
Open Access
- 25 October 2023
- journal article
- research article
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-13
Abstract
Matrix imaging paves the way towards a next revolution in wave physics. Based on the response matrix recorded between a set of sensors, it enables an optimized compensation of aberration phenomena and multiple scattering events that usually drastically hinder the focusing process in heterogeneous media. Although it gave rise to spectacular results in optical microscopy or seismic imaging, the success of matrix imaging has been so far relatively limited with ultrasonic waves because wave control is generally only performed with a linear array of transducers. In this paper, we extend ultrasound matrix imaging to a 3D geometry. Switching from a 1D to a 2D probe enables a much sharper estimation of the transmission matrix that links each transducer and each medium voxel. Here, we first present an experimental proof of concept on a tissue-mimicking phantom through ex-vivo tissues and then, show the potential of 3D matrix imaging for transcranial applications.Keywords
All Related Versions
This publication has 60 references indexed in Scilit:
- Time Reversal of Speckle NoisePhysical Review Letters, 2011
- Going deeper than microscopy: the optical imaging frontier in biologyNature Methods, 2010
- Real-Time 3-D Contrast-Enhanced Transcranial Ultrasound and Aberration CorrectionUltrasound in Medicine & Biology, 2008
- 3-D real-time motion correction in high-intensity focused ultrasound therapyUltrasound in Medicine & Biology, 2004
- Time-shift estimation and focusing through distributed aberration using multirow arraysIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2001
- Adaptive focusing in scattering media through sound-speed inhomogeneities: The van Cittert Zernike approach and focusing criterionThe Journal of the Acoustical Society of America, 1994
- Phase Aberration Correction Using Echo Signals from Moving Targets I: Description and TheoryUltrasonic Imaging, 1992
- Phase aberration correction in medical ultrasound using speckle brightness as a quality factorThe Journal of the Acoustical Society of America, 1989
- Compilation of empirical ultrasonic properties of mammalian tissues. IIThe Journal of the Acoustical Society of America, 1980
- The Possibility of Compensating Astronomical SeeingPublications of the Astronomical Society of the Pacific, 1953