High Frame Rate Volumetric Imaging of Microbubbles Using a Sparse Array and Spatial Coherence Beamforming
Authors:
- Luxi WeiLWLuxi Wei
- Bram MeijlinkBMBram Meijlink
- Alessandro RamalliAlessandro Ramalli
- Martin D. VerweijMVMartin D. Verweij
- Enrico BoniEnrico Boni
- Klazina KooimanKKKlazina Kooiman
- Antonius F. W. van der SteenASAntonius F. W. van der Steen
- Piero TortoliPiero Tortoli
- Nico de JongNJNico de Jong
- Hendrik J. VosHVHendrik J. Vos
Open Access
- 4 June 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (10) , 3069-3081
Abstract
Volumetric ultrasound imaging of blood flow with microbubbles enables a more complete visualization of the microvasculature. Sparse arrays are ideal candidates to perform volumetric imaging at reduced manufacturing complexity and cable count. However, due to the small number of transducer elements, sparse arrays often come with high clutter levels, especially when wide beams are transmitted to increase the frame rate. In this study, we demonstrate with a prototype sparse array probe and a diverging wave transmission strategy, that a uniform transmission field can be achieved. With the implementation of a spatial coherence beamformer, the background clutter signal can be effectively suppressed, leading to a signal to background ratio improvement of 25 dB. With this approach, we demonstrate the volumetric visualization of single microbubbles in a tissue-mimicking phantom as well as vasculature mapping in a live chicken embryo chorioallantoic membrane.Keywords
Funding Information
- Dutch Research Council (NWO) through the research programme “Vernieuwingsimpuls–Vidi 2017” (QUANTO-16572)
- Medical Delta Scientific Program, The Netherlands, through UltraHB Project
This publication has 41 references indexed in Scilit:
- Density-tapered spiral arrays for ultrasound 3-D imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2015
- Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound SensitivityIEEE Transactions on Medical Imaging, 2015
- Short-lag spatial coherence imaging on matrix arrays, Part II: Phantom and in vivo experimentsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- Short-lag spatial coherence imaging on matrix arrays, Part 1: Beamforming methods and simulation studiesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- Quantification of Blood Flow and Topology in Developing Vascular NetworksPLOS ONE, 2014
- Guidelines and Good Clinical Practice Recommendations for Contrast Enhanced Ultrasound (CEUS) in the Liver – Update 2012Ultrasound in Medicine & Biology, 2013
- Short-lag spatial coherence of backscattered echoes: imaging characteristicsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2011
- Theoretical assessment of a crossed electrode 2-D array for 3-D imaging2004
- Threshold of fragmentation for ultrasonic contrast agentsJournal of Biomedical Optics, 2001
- The van Cittert–Zernike theorem in pulse echo measurementsThe Journal of the Acoustical Society of America, 1991