Bram Meijlink
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bram Meijlink has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Klazina Kooiman
Biomedical Engineering, Department of Cardiology, Cardiovascular Institute, Erasmus MC, Rotterdam, The Netherlands
7 shared publications - Antonius F. W. van der Steen
Biomedical Engineering, Department of Cardiology, Cardiovascular Institute, Erasmus MC, Rotterdam, The Netherlands
3 shared publications - Nico de Jong
Biomedical Engineering, Department of Cardiology, Cardiovascular Institute, Erasmus MC, Rotterdam, The Netherlands
3 shared publications - Simone A. G. Langeveld
Department of Biomedical Engineering, Thoraxcenter, Erasmus MC University Medical Center Rotterdam, Office Ee2302, P.O. Box 2040, 3000 CA Rotterdam, the Netherlands
3 shared publications Antonius F. W. van der Steen
Biomedical Engineering Department of Cardiology Cardiovascular Institute Erasmus MC Wytemaweg 80 Rotterdam 3015 CN The Netherlands
2 shared publications- Gijsje Hendrika Koenderink
Department of Bionanoscience, Kavli Institute of Nanoscience Delft, Delft University of Technology, Delft, the Netherlands
2 shared publications
Latest Publications
- Open Access
Characterizing Microbubble‐Mediated Permeabilization in a Vessel‐on‐a‐Chip Model
Drug transport from blood to extravascular tissue can locally be achieved by increasing the vascular permeability through ultrasound‐activated microbubbles. However, the mechanism remains unknown, including whether short and long cycles of ultrasound induce the same onset rate, spatial distribution, and amount of vascular permeability increase. Accurate models are necessary for insights into the mechanism so a microvessel‐on‐a‐chip is developed with a membrane‐free extravascular space. Using these microvessels‐on‐a‐chip, distinct differences between 2 MHz ultrasound treatments are shown with 10 or 1000 cycles. The onset rate is slower for 10 than 1000 cycles, while both cycle lengths increase the permeability in spot‐wise patterns without affecting microvessel viability. Significantly less vascular permeability increase and sonoporation are induced for 10 versus 1000 cycles at 750 kPa (i.e., the highest studied peak negative acoustic pressure (PNP)). The PNP threshold for vascular permeability increases is 750 versus 550 kPa for 10 versus 1000 cycles, while this is 750 versus 220 kPa for sonoporation. Vascular permeability increases do not correlate with αvβ3‐targeted microbubble behavior, while sonoporation correlates with αvβ3‐targeted microbubble clustering. In conclusion, the further mechanistic unraveling of vascular permeability increase by ultrasound‐activated microbubbles in a developed microvessel‐on‐a‐chip model aids the safe and efficient development of microbubble‐mediated drug transport.
Open AccessCharacterizing Microbubble‐Mediated Permeabilization in a Vessel‐on‐a‐Chip Model
Drug transport from blood to extravascular tissue can locally be achieved by increasing the vascular permeability through ultrasound‐activated microbubbles. However, the mechanism remains unknown, including whether short and long cycles of ultrasound induce the same onset rate, spatial distribution, and amount of vascular permeability increase. Accurate models are necessary for insights into the mechanism so a microvessel‐on‐a‐chip is developed with a membrane‐free extravascular space. Using these microvessels‐on‐a‐chip, distinct differences between 2 MHz ultrasound treatments are shown with 10 or 1000 cycles. The onset rate is slower for 10 than 1000 cycles, while both cycle lengths increase the permeability in spot‐wise patterns without affecting microvessel viability. Significantly less vascular permeability increase and sonoporation are induced for 10 versus 1000 cycles at 750 kPa (i.e., the highest studied peak negative acoustic pressure (PNP)). The PNP threshold for vascular permeability increases is 750 versus 550 kPa for 10 versus 1000 cycles, while this is 750 versus 220 kPa for sonoporation. Vascular permeability increases do not correlate with αvβ3‐targeted microbubble behavior, while sonoporation correlates with αvβ3‐targeted microbubble clustering. In conclusion, the further mechanistic unraveling of vascular permeability increase by ultrasound‐activated microbubbles in a developed microvessel‐on‐a‐chip model aids the safe and efficient development of microbubble‐mediated drug transport.
- Open Access
Ultrasound-activated microbubbles mediate F-actin disruptions and endothelial gap formation during sonoporation
Locally opening up the endothelial barrier in a safe and controlled way is beneficial for drug delivery into the extravascular tissue. Although ultrasound-induced microbubble oscillations can affect endothelial barrier integrity, the mechanism remains unknown. Here we uncover a new role for F-actin in microbubble-mediated endothelial gap formation. Unique simultaneous high-resolution confocal microscopy and ultra-high-speed camera imaging (10 million frames per second) reveal that oscillating microbubbles (radius 1.3-3.8 µm) induce sonoporation in all cells in which F-actin remodeling occurred. F-actin disruption only mainly resulted in tunnel formation (75%) and F-actin stress fiber severing and recoil mainly resulted in cell-cell contact opening within 15 s upon treatment (54%) and tunnel formation (15%). Stress fiber severing occurred when fibers were within reach of the microbubble’s maximum radius during oscillation, requiring normal forces of ≥230 nN. Together, these findings reveal a novel mechanism of microbubble-mediated drug delivery, which associates with the underlying cytoskeletal organization.
Open AccessUltrasound-activated microbubbles mediate F-actin disruptions and endothelial gap formation during sonoporation
Locally opening up the endothelial barrier in a safe and controlled way is beneficial for drug delivery into the extravascular tissue. Although ultrasound-induced microbubble oscillations can affect endothelial barrier integrity, the mechanism remains unknown. Here we uncover a new role for F-actin in microbubble-mediated endothelial gap formation. Unique simultaneous high-resolution confocal microscopy and ultra-high-speed camera imaging (10 million frames per second) reveal that oscillating microbubbles (radius 1.3-3.8 µm) induce sonoporation in all cells in which F-actin remodeling occurred. F-actin disruption only mainly resulted in tunnel formation (75%) and F-actin stress fiber severing and recoil mainly resulted in cell-cell contact opening within 15 s upon treatment (54%) and tunnel formation (15%). Stress fiber severing occurred when fibers were within reach of the microbubble’s maximum radius during oscillation, requiring normal forces of ≥230 nN. Together, these findings reveal a novel mechanism of microbubble-mediated drug delivery, which associates with the underlying cytoskeletal organization.
- Open Access
Characterizing microbubble-mediated permeabilization in a vessel-on-a-chip model
Drug transport from blood to extravascular tissue can locally be achieved by increasing the vascular permeability through ultrasound-activated microbubbles. However, the mechanism remains unknown, including whether short and long cycles of ultrasound induce the same onset rate, spatial distribution, and amount of vascular permeability increase. Accurate models are necessary for insights into the mechanism so a microvessel-on-a-chip is developed with a membrane-free extravascular space. Using these microvessels-on-a-chip, we show distinct differences between 2 MHz ultrasound treatments with 10 or 1000 cycles. The onset rate is slower for 10 than 1000 cycles, while both cycle lengths increase the permeability in spot-wise patterns without affecting cell viability. Significantly less vascular permeability increase and sonoporation are induced for 10 versus 1000 cycles at 750 kPa (i.e., highest studied peak negative acoustic pressure (PNP)). The PNP threshold for vascular permeability increases is 750 versus 550 kPa for 10 versus 1000 cycles, while this is 750 versus 220 kPa for sonoporation. Vascular permeability increases do not correlate with α v β 3 -targeted microbubble behavior, while sonoporation correlates with α v β 3 -targeted microbubble clustering. In conclusion, the further mechanistic unraveling of vascular permeability increase by ultrasound-activated microbubbles in a developed microvessel-on-a-chip model aids safe and efficient development of microbubble-mediated drug transport.
Open AccessCharacterizing microbubble-mediated permeabilization in a vessel-on-a-chip model
Drug transport from blood to extravascular tissue can locally be achieved by increasing the vascular permeability through ultrasound-activated microbubbles. However, the mechanism remains unknown, including whether short and long cycles of ultrasound induce the same onset rate, spatial distribution, and amount of vascular permeability increase. Accurate models are necessary for insights into the mechanism so a microvessel-on-a-chip is developed with a membrane-free extravascular space. Using these microvessels-on-a-chip, we show distinct differences between 2 MHz ultrasound treatments with 10 or 1000 cycles. The onset rate is slower for 10 than 1000 cycles, while both cycle lengths increase the permeability in spot-wise patterns without affecting cell viability. Significantly less vascular permeability increase and sonoporation are induced for 10 versus 1000 cycles at 750 kPa (i.e., highest studied peak negative acoustic pressure (PNP)). The PNP threshold for vascular permeability increases is 750 versus 550 kPa for 10 versus 1000 cycles, while this is 750 versus 220 kPa for sonoporation. Vascular permeability increases do not correlate with α v β 3 -targeted microbubble behavior, while sonoporation correlates with α v β 3 -targeted microbubble clustering. In conclusion, the further mechanistic unraveling of vascular permeability increase by ultrasound-activated microbubbles in a developed microvessel-on-a-chip model aids safe and efficient development of microbubble-mediated drug transport.
- Open Access
- 28 January 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (2) , 311
Theranostic Microbubbles with Homogeneous Ligand Distribution for Higher Binding Efficacy
Phospholipid-coated targeted microbubbles are used for ultrasound molecular imaging and locally enhanced drug delivery, with the binding efficacy being an important trait. The use of organic solvent in microbubble production makes the difference between a heterogeneous or homogeneous ligand distribution. This study demonstrates the effect of ligand distribution on the binding efficacy of phospholipid-coated ανβ3-targeted microbubbles in vitro using a monolayer of human umbilical-vein endothelial cells and in vivo using chicken embryos. Microbubbles with a homogeneous ligand distribution had a higher binding efficacy than those with a heterogeneous ligand distribution both in vitro and in vivo. In vitro, 1.55× more microbubbles with a homogeneous ligand distribution bound under static conditions, while this was 1.49× more under flow with 1.25 dyn/cm2, 1.56× more under flow with 2.22 dyn/cm2, and 1.25× more in vivo. The in vitro dissociation rate of bound microbubbles with homogeneous ligand distribution was lower at low shear stresses (1–5 dyn/cm2). The internalized depth of bound microbubbles was influenced by microbubble size, not by ligand distribution. In conclusion, for optimal binding the use of organic solvent in targeted microbubble production is preferable over directly dispersing phospholipids in aqueous medium.
- 28 January 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (2) , 311
Open AccessTheranostic Microbubbles with Homogeneous Ligand Distribution for Higher Binding Efficacy
Phospholipid-coated targeted microbubbles are used for ultrasound molecular imaging and locally enhanced drug delivery, with the binding efficacy being an important trait. The use of organic solvent in microbubble production makes the difference between a heterogeneous or homogeneous ligand distribution. This study demonstrates the effect of ligand distribution on the binding efficacy of phospholipid-coated ανβ3-targeted microbubbles in vitro using a monolayer of human umbilical-vein endothelial cells and in vivo using chicken embryos. Microbubbles with a homogeneous ligand distribution had a higher binding efficacy than those with a heterogeneous ligand distribution both in vitro and in vivo. In vitro, 1.55× more microbubbles with a homogeneous ligand distribution bound under static conditions, while this was 1.49× more under flow with 1.25 dyn/cm2, 1.56× more under flow with 2.22 dyn/cm2, and 1.25× more in vivo. The in vitro dissociation rate of bound microbubbles with homogeneous ligand distribution was lower at low shear stresses (1–5 dyn/cm2). The internalized depth of bound microbubbles was influenced by microbubble size, not by ligand distribution. In conclusion, for optimal binding the use of organic solvent in targeted microbubble production is preferable over directly dispersing phospholipids in aqueous medium.
- Open Access
- 1 August 2021
- Published by Elsevier in Current Opinion in Chemical Biology
- Vol. 63, 171-179
Phospholipid-coated targeted microbubbles for ultrasound molecular imaging and therapy
- 1 August 2021
- Published by Elsevier in Current Opinion in Chemical Biology
- Vol. 63, 171-179
Open AccessPhospholipid-coated targeted microbubbles for ultrasound molecular imaging and therapy
- Open Access
- 4 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (10) , 3069-3081
High Frame Rate Volumetric Imaging of Microbubbles Using a Sparse Array and Spatial Coherence Beamforming
Volumetric ultrasound imaging of blood flow with microbubbles enables a more complete visualization of the microvasculature. Sparse arrays are ideal candidates to perform volumetric imaging at reduced manufacturing complexity and cable count. However, due to the small number of transducer elements, sparse arrays often come with high clutter levels, especially when wide beams are transmitted to increase the frame rate. In this study, we demonstrate with a prototype sparse array probe and a diverging wave transmission strategy, that a uniform transmission field can be achieved. With the implementation of a spatial coherence beamformer, the background clutter signal can be effectively suppressed, leading to a signal to background ratio improvement of 25 dB. With this approach, we demonstrate the volumetric visualization of single microbubbles in a tissue-mimicking phantom as well as vasculature mapping in a live chicken embryo chorioallantoic membrane.
- 4 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (10) , 3069-3081
Open AccessHigh Frame Rate Volumetric Imaging of Microbubbles Using a Sparse Array and Spatial Coherence Beamforming
Volumetric ultrasound imaging of blood flow with microbubbles enables a more complete visualization of the microvasculature. Sparse arrays are ideal candidates to perform volumetric imaging at reduced manufacturing complexity and cable count. However, due to the small number of transducer elements, sparse arrays often come with high clutter levels, especially when wide beams are transmitted to increase the frame rate. In this study, we demonstrate with a prototype sparse array probe and a diverging wave transmission strategy, that a uniform transmission field can be achieved. With the implementation of a spatial coherence beamformer, the background clutter signal can be effectively suppressed, leading to a signal to background ratio improvement of 25 dB. With this approach, we demonstrate the volumetric visualization of single microbubbles in a tissue-mimicking phantom as well as vasculature mapping in a live chicken embryo chorioallantoic membrane.
- Open Access
- 6 May 2021
- Published by Rockefeller University Press in Journal of General Physiology
- Vol. 153 (6)
CaMKII inhibition reduces arrhythmogenic Ca2+ events in subendocardial cryoinjured rat living myocardial slices
Spontaneous Ca2+ release (SCR) can cause triggered activity and initiate arrhythmias. Intrinsic transmural heterogeneities in Ca2+ handling and their propensity to disease remodeling may differentially modulate SCR throughout the left ventricular (LV) wall and cause transmural differences in arrhythmia susceptibility. Here, we aimed to dissect the effect of cardiac injury on SCR in different regions in the intact LV myocardium using cryoinjury on rat living myocardial slices (LMS). We studied SCR under proarrhythmic conditions using a fluorescent Ca2+ indicator and high-resolution imaging in LMS from the subendocardium (ENDO) and subepicardium (EPI). Cryoinjury caused structural remodeling, with loss in T-tubule density and an increased time of Ca2+ transients to peak after injury. In ENDO LMS, the Ca2+ transient amplitude and decay phase were reduced, while these were not affected in EPI LMS after cryoinjury. The frequency of spontaneous whole-slice contractions increased in ENDO LMS without affecting EPI LMS after injury. Cryoinjury caused an increase in foci that generates SCR in both ENDO and EPI LMS. In ENDO LMS, SCRs were more closely distributed and had reduced latencies after cryoinjury, whereas this was not affected in EPI LMS. Inhibition of CaMKII reduced the number, distribution, and latencies of SCR, as well as whole-slice contractions in ENDO LMS, but not in EPI LMS after cryoinjury. Furthermore, CaMKII inhibition did not affect the excitation–contraction coupling in cryoinjured ENDO or EPI LMS. In conclusion, we demonstrate increased arrhythmogenic susceptibility in the injured ENDO. Our findings show involvement of CaMKII and highlight the need for region-specific targeting in cardiac therapies.
- 6 May 2021
- Published by Rockefeller University Press in Journal of General Physiology
- Vol. 153 (6)
Open AccessCaMKII inhibition reduces arrhythmogenic Ca2+ events in subendocardial cryoinjured rat living myocardial slices
Spontaneous Ca2+ release (SCR) can cause triggered activity and initiate arrhythmias. Intrinsic transmural heterogeneities in Ca2+ handling and their propensity to disease remodeling may differentially modulate SCR throughout the left ventricular (LV) wall and cause transmural differences in arrhythmia susceptibility. Here, we aimed to dissect the effect of cardiac injury on SCR in different regions in the intact LV myocardium using cryoinjury on rat living myocardial slices (LMS). We studied SCR under proarrhythmic conditions using a fluorescent Ca2+ indicator and high-resolution imaging in LMS from the subendocardium (ENDO) and subepicardium (EPI). Cryoinjury caused structural remodeling, with loss in T-tubule density and an increased time of Ca2+ transients to peak after injury. In ENDO LMS, the Ca2+ transient amplitude and decay phase were reduced, while these were not affected in EPI LMS after cryoinjury. The frequency of spontaneous whole-slice contractions increased in ENDO LMS without affecting EPI LMS after injury. Cryoinjury caused an increase in foci that generates SCR in both ENDO and EPI LMS. In ENDO LMS, SCRs were more closely distributed and had reduced latencies after cryoinjury, whereas this was not affected in EPI LMS. Inhibition of CaMKII reduced the number, distribution, and latencies of SCR, as well as whole-slice contractions in ENDO LMS, but not in EPI LMS after cryoinjury. Furthermore, CaMKII inhibition did not affect the excitation–contraction coupling in cryoinjured ENDO or EPI LMS. In conclusion, we demonstrate increased arrhythmogenic susceptibility in the injured ENDO. Our findings show involvement of CaMKII and highlight the need for region-specific targeting in cardiac therapies.
- 9 February 2021
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 168,p. e62076
The Preparation of Chicken Ex Ovo Embryos and Chorioallantoic Membrane Vessels as In Vivo Model for Contrast-Enhanced Ultrasound Imaging and Microbubble-Mediated Drug Delivery Studies
The chicken embryo and the blood-vessel rich chorioallantoic membrane (CAM) is a valuable in vivo model to investigate biomedical processes, new ultrasound pulsing schemes, or novel transducers for contrast-enhanced ultrasound imaging and microbubble-mediated drug delivery. The reasons for this are the accessibility of the embryo and vessel network of the CAM as well as the low costs of the model. An important step to get access to the embryo and CAM vessels is to take the egg content out of the eggshell. In this protocol, three methods for taking the content out of the eggshell between day 5 and 8 of incubation are described thus allowing the embryos to develop inside the eggshell up to these days. The described methods only require simple tools and equipment and yield a higher survival success rate of 90% for 5-day, 75% for 6-day, 50% for 7-day, and 60% for 8-day old incubated eggs in comparison to ex ovo cultured embryos (~50%). The protocol also describes how to inject cavitation nuclei, such as microbubbles, into the CAM vascular system, how to separate the membrane containing the embryo and CAM from the rest of the egg content for optically transparent studies, and how to use the chicken embryo and CAM in a variety of short-term ultrasound experiments. The in vivo chicken embryo and CAM model is extremely relevant to investigate novel imaging protocols, ultrasound contrast agents, and ultrasound pulsing schemes for contrast-enhanced ultrasound imaging, and to unravel the mechanisms of ultrasound-mediated drug delivery.
- 9 February 2021
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 168,p. e62076
The Preparation of Chicken Ex Ovo Embryos and Chorioallantoic Membrane Vessels as In Vivo Model for Contrast-Enhanced Ultrasound Imaging and Microbubble-Mediated Drug Delivery Studies
The chicken embryo and the blood-vessel rich chorioallantoic membrane (CAM) is a valuable in vivo model to investigate biomedical processes, new ultrasound pulsing schemes, or novel transducers for contrast-enhanced ultrasound imaging and microbubble-mediated drug delivery. The reasons for this are the accessibility of the embryo and vessel network of the CAM as well as the low costs of the model. An important step to get access to the embryo and CAM vessels is to take the egg content out of the eggshell. In this protocol, three methods for taking the content out of the eggshell between day 5 and 8 of incubation are described thus allowing the embryos to develop inside the eggshell up to these days. The described methods only require simple tools and equipment and yield a higher survival success rate of 90% for 5-day, 75% for 6-day, 50% for 7-day, and 60% for 8-day old incubated eggs in comparison to ex ovo cultured embryos (~50%). The protocol also describes how to inject cavitation nuclei, such as microbubbles, into the CAM vascular system, how to separate the membrane containing the embryo and CAM from the rest of the egg content for optically transparent studies, and how to use the chicken embryo and CAM in a variety of short-term ultrasound experiments. The in vivo chicken embryo and CAM model is extremely relevant to investigate novel imaging protocols, ultrasound contrast agents, and ultrasound pulsing schemes for contrast-enhanced ultrasound imaging, and to unravel the mechanisms of ultrasound-mediated drug delivery.