Intracardiac Induced Ventricular Fibrillation for the Euthanasia of Sheep
Authors:
- 1 September 2023
- journal article
- research article
- Published by American Association for Laboratory Animal Science in Journal of the American Association for Laboratory Animal Science
- Vol. 62 (5) , 464-469
Abstract
Euthanasia is the humane termination of an animal's life and an important consideration for scientists, veterinarians, regulators, and others contemplating investigations involving animals. Techniques for euthanasia must induce the most rapid, painless, and distress-free death possible. This study investigated the effectiveness of direct current induction of ventricular fibrillation for the euthanasia of sheep after a primary study in which artifacts or chemical contamination from injectable euthanasia agents were undesirable. Female crossbred adult sheep (Ovis aries; n = 12) under deep isoflurane general anesthesia were instrumented with electrophysiology catheters to induce ventricular fibrillation for euthanasia. Data regarding invasive arterial blood pressure, expired airway gases, limb lead electrocardiograms, and pulse oximetry were collected and assessed just prior to, immediately after, and at 5, 10, 15, and 20 min after energy delivery. In all animals, a single 10-s application of 9V of direct current to the right ventricular endocardium via the electrophysiology catheter induced persistent ventricular fibrillation. Arterial blood pressure (mean +/- 1 SD) immediately after fibrillation induction was 22.9 +/- 4.5 mm Hg, with negligible difference between systolic and diastolic pressures. The lack of differential pressure continued through the end of the monitoring period. Arterial blood pressure reached an initial nadir at 1 +/- 0.5 min after fibrillation induction, peaked (40.8 +/- 11.1 mm Hg) due to a vasoconstrictive reflex at 3 min after induction, and returned to a static uniform pressure (20.4 +/- 17.8 mm Hg) with mildly increased variability due to reflexive diaphragmatic contractions at 10 min after induction. The use of 9V direct current for the induction of ventricular fibrillation via an electrophysiology catheter is a reliable method of euthanasia in sheep.Keywords
This publication has 21 references indexed in Scilit:
- Self-Terminated Ventricular Fibrillation and Recurrent SyncopeThe American Journal of Cardiology, 2011
- Transmural optical measurements of Vm dynamics during long-duration ventricular fibrillation in canine heartsHeart Rhythm, 2009
- Increased cycle length during long-duration ventricular fibrillation is caused by decreased upstroke velocity as well as prolonged refractorinessHeart Rhythm, 2009
- Mechanisms of VF maintenance: Wandering wavelets, mother rotors, or fociHeart Rhythm, 2009
- Barbiturate euthanasia solution‐induced tissue artifact in nonhuman primatesJournal of Medical Primatology, 2007
- Spontaneous termination of ventricular fibrillationHeart, 2004
- Shock on T Versus Direct Current Voltage for Induction of Ventricular Fibrillation:Pacing and Clinical Electrophysiology, 2004
- Low Voltage Direct Current Delivered Through Unipolar Transvenous Leads: An Alternate Method for the Induction of Ventricnlar FibrillationPacing and Clinical Electrophysiology, 1999
- Direct Current Application: Easy Induction of Ventricular Fibrillation for the Determination of the Defibrillation Threshold in Patients with Implantable Cardioverter DefibrillatorsPacing and Clinical Electrophysiology, 1992
- VENTRICULAR SELF-DEFIBRILLATION IN MAMMALS: AGE AND DRUG DEPENDENCEAge and Ageing, 1980