Noah Barka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Noah Barka has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Nancy Rakow
3 shared publications- Atul Verma
McGill University Health Center, Montréal, Canada (A.V.).
2 shared publications - Birce Onal
Medtronic, Inc, Minneapolis, MN (B.O., J.C.).
2 shared publications Erin Grassl
Physiological Research Laboratories, Medtronic PLC., Minneapolis, MN, USA
2 shared publicationsJ. A. St.Cyr
Physiological Research Laboratories, Inc.; Medtronic, Inc.; Minneapolis Minnesota 55448
2 shared publicationsLynette Phillips
Physiological Research Laboratories, Inc.; Medtronic, Inc.; Minneapolis Minnesota 55448
2 shared publications
Latest Publications
- 1 September 2023
- Published by American Association for Laboratory Animal Science in Journal of the American Association for Laboratory Animal Science
- Vol. 62 (5) , 464-469
Intracardiac Induced Ventricular Fibrillation for the Euthanasia of Sheep
Euthanasia is the humane termination of an animal's life and an important consideration for scientists, veterinarians, regulators, and others contemplating investigations involving animals. Techniques for euthanasia must induce the most rapid, painless, and distress-free death possible. This study investigated the effectiveness of direct current induction of ventricular fibrillation for the euthanasia of sheep after a primary study in which artifacts or chemical contamination from injectable euthanasia agents were undesirable. Female crossbred adult sheep (Ovis aries; n = 12) under deep isoflurane general anesthesia were instrumented with electrophysiology catheters to induce ventricular fibrillation for euthanasia. Data regarding invasive arterial blood pressure, expired airway gases, limb lead electrocardiograms, and pulse oximetry were collected and assessed just prior to, immediately after, and at 5, 10, 15, and 20 min after energy delivery. In all animals, a single 10-s application of 9V of direct current to the right ventricular endocardium via the electrophysiology catheter induced persistent ventricular fibrillation. Arterial blood pressure (mean +/- 1 SD) immediately after fibrillation induction was 22.9 +/- 4.5 mm Hg, with negligible difference between systolic and diastolic pressures. The lack of differential pressure continued through the end of the monitoring period. Arterial blood pressure reached an initial nadir at 1 +/- 0.5 min after fibrillation induction, peaked (40.8 +/- 11.1 mm Hg) due to a vasoconstrictive reflex at 3 min after induction, and returned to a static uniform pressure (20.4 +/- 17.8 mm Hg) with mildly increased variability due to reflexive diaphragmatic contractions at 10 min after induction. The use of 9V direct current for the induction of ventricular fibrillation via an electrophysiology catheter is a reliable method of euthanasia in sheep.
- 1 September 2023
- Published by American Association for Laboratory Animal Science in Journal of the American Association for Laboratory Animal Science
- Vol. 62 (5) , 464-469
Intracardiac Induced Ventricular Fibrillation for the Euthanasia of Sheep
Euthanasia is the humane termination of an animal's life and an important consideration for scientists, veterinarians, regulators, and others contemplating investigations involving animals. Techniques for euthanasia must induce the most rapid, painless, and distress-free death possible. This study investigated the effectiveness of direct current induction of ventricular fibrillation for the euthanasia of sheep after a primary study in which artifacts or chemical contamination from injectable euthanasia agents were undesirable. Female crossbred adult sheep (Ovis aries; n = 12) under deep isoflurane general anesthesia were instrumented with electrophysiology catheters to induce ventricular fibrillation for euthanasia. Data regarding invasive arterial blood pressure, expired airway gases, limb lead electrocardiograms, and pulse oximetry were collected and assessed just prior to, immediately after, and at 5, 10, 15, and 20 min after energy delivery. In all animals, a single 10-s application of 9V of direct current to the right ventricular endocardium via the electrophysiology catheter induced persistent ventricular fibrillation. Arterial blood pressure (mean +/- 1 SD) immediately after fibrillation induction was 22.9 +/- 4.5 mm Hg, with negligible difference between systolic and diastolic pressures. The lack of differential pressure continued through the end of the monitoring period. Arterial blood pressure reached an initial nadir at 1 +/- 0.5 min after fibrillation induction, peaked (40.8 +/- 11.1 mm Hg) due to a vasoconstrictive reflex at 3 min after induction, and returned to a static uniform pressure (20.4 +/- 17.8 mm Hg) with mildly increased variability due to reflexive diaphragmatic contractions at 10 min after induction. The use of 9V direct current for the induction of ventricular fibrillation via an electrophysiology catheter is a reliable method of euthanasia in sheep.
- Open Access
- 10 November 2022
- Published by Wolters Kluwer Health in Pain Reports
- Vol. 7 (6) , e1047
Using evoked compound action potentials to quantify differential neural activation with burst and conventional, 40 Hz spinal cord stimulation in ovines
Introduction and Objectives:Unlike conventional dorsal spinal cord stimulation (SCS)-which uses single pulses at a fixed rate-burst SCS uses a fixed-rate, five-pulse stimuli cluster as a treatment for chronic pain; mechanistic explanations suggest burst SCS differentially modulate the medial and lateral pain pathways vs conventional SCS. Neural activation differences between burst and conventional SCS are quantifiable with the spinal-evoked compound action potential (ECAP), an electrical measure of synchronous neural activation.Methods:We implanted 7 sheep with a dorsal stimulation lead at T9/T10, a dorsal ECAP sensing lead at T6/T7, and a lead also at T9/T10 but adjacent to the anterolateral system (ALS). Both burst and conventional SCS with stimulation amplitudes up to the visual motor threshold (vMT) were delivered to 3 different dorsal spinal locations, and ECAP thresholds (ECAPTs) were calculated for all combinations. Then, changes in ALS activation were assessed with both types of SCS.Results:Evoked compound action potential thresholds and vMTs were significantly higher (P < 0.05) with conventional vs burst SCS, with no statistical difference (P > 0.05) among stimulation sites. However, the vMT-ECAPT window (a proxy for the useable therapeutic dosing range) was significantly wider (P < 0.05) with conventional vs burst SCS. No significant difference (P > 0.05) in ALS activation was noted between conventional and burst SCS.Conclusion:When dosed equivalently, no differentially unique change in ALS activation results with burst SCS vs conventional SCS; in addition, sub-ECAPT burst SCS results in no discernable excitability changes in the neural pathways feeding pain relevant supraspinal sites.
- 10 November 2022
- Published by Wolters Kluwer Health in Pain Reports
- Vol. 7 (6) , e1047
Open AccessUsing evoked compound action potentials to quantify differential neural activation with burst and conventional, 40 Hz spinal cord stimulation in ovines
Introduction and Objectives:Unlike conventional dorsal spinal cord stimulation (SCS)-which uses single pulses at a fixed rate-burst SCS uses a fixed-rate, five-pulse stimuli cluster as a treatment for chronic pain; mechanistic explanations suggest burst SCS differentially modulate the medial and lateral pain pathways vs conventional SCS. Neural activation differences between burst and conventional SCS are quantifiable with the spinal-evoked compound action potential (ECAP), an electrical measure of synchronous neural activation.Methods:We implanted 7 sheep with a dorsal stimulation lead at T9/T10, a dorsal ECAP sensing lead at T6/T7, and a lead also at T9/T10 but adjacent to the anterolateral system (ALS). Both burst and conventional SCS with stimulation amplitudes up to the visual motor threshold (vMT) were delivered to 3 different dorsal spinal locations, and ECAP thresholds (ECAPTs) were calculated for all combinations. Then, changes in ALS activation were assessed with both types of SCS.Results:Evoked compound action potential thresholds and vMTs were significantly higher (P < 0.05) with conventional vs burst SCS, with no statistical difference (P > 0.05) among stimulation sites. However, the vMT-ECAPT window (a proxy for the useable therapeutic dosing range) was significantly wider (P < 0.05) with conventional vs burst SCS. No significant difference (P > 0.05) in ALS activation was noted between conventional and burst SCS.Conclusion:When dosed equivalently, no differentially unique change in ALS activation results with burst SCS vs conventional SCS; in addition, sub-ECAPT burst SCS results in no discernable excitability changes in the neural pathways feeding pain relevant supraspinal sites.
- Top Cited PapersOpen Access
- 1 June 2022
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 15 (6) , e010127
Characterization of Phrenic Nerve Response to Pulsed Field Ablation
Background: Phrenic nerve palsy is a well-known complication of cardiac ablation, resulting from the application of direct thermal energy. Emerging pulsed field ablation (PFA) may reduce the risk of phrenic nerve injury but has not been well characterized. Methods: Accelerometers and continuous pacing were used during PFA deliveries in a porcine model. Acute dose response was established in a first experimental phase with ascending PFA intensity delivered to the phrenic nerve (n=12). In a second phase, nerves were targeted with a single ablation level to observe the effect of repetitive ablations on nerve function (n=4). A third chronic phase characterized assessed histopathology of nerves adjacent to ablated cardiac tissue (n=6). Results: Acutely, we observed a dose-dependent response in phrenic nerve function including reversible stunning (R 2 =0.965, P <0.001). Furthermore, acute results demonstrated that phrenic nerve function responded to varying levels of PFA and catheter proximity placements, resulting in either: no effect, effect, or stunning. In the chronic study phase, successful isolation of superior vena cava at a dose not predicted to cause phrenic nerve dysfunction was associated with normal phrenic nerve function and normal phrenic nerve histopathology at 4 weeks. Conclusions: Proximity of the catheter to the phrenic nerve and the PFA dose level were critical for phrenic nerve response. Gross and histopathologic evaluation of phrenic nerves and diaphragms at a chronic time point yielded no injury. These results provide a basis for understanding the susceptibility and recovery of phrenic nerves in response to PFA and a need for appropriate caution in moving beyond animal models.
- 1 June 2022
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 15 (6) , e010127
Top Cited PapersOpen AccessCharacterization of Phrenic Nerve Response to Pulsed Field Ablation
Background: Phrenic nerve palsy is a well-known complication of cardiac ablation, resulting from the application of direct thermal energy. Emerging pulsed field ablation (PFA) may reduce the risk of phrenic nerve injury but has not been well characterized. Methods: Accelerometers and continuous pacing were used during PFA deliveries in a porcine model. Acute dose response was established in a first experimental phase with ascending PFA intensity delivered to the phrenic nerve (n=12). In a second phase, nerves were targeted with a single ablation level to observe the effect of repetitive ablations on nerve function (n=4). A third chronic phase characterized assessed histopathology of nerves adjacent to ablated cardiac tissue (n=6). Results: Acutely, we observed a dose-dependent response in phrenic nerve function including reversible stunning (R 2 =0.965, P <0.001). Furthermore, acute results demonstrated that phrenic nerve function responded to varying levels of PFA and catheter proximity placements, resulting in either: no effect, effect, or stunning. In the chronic study phase, successful isolation of superior vena cava at a dose not predicted to cause phrenic nerve dysfunction was associated with normal phrenic nerve function and normal phrenic nerve histopathology at 4 weeks. Conclusions: Proximity of the catheter to the phrenic nerve and the PFA dose level were critical for phrenic nerve response. Gross and histopathologic evaluation of phrenic nerves and diaphragms at a chronic time point yielded no injury. These results provide a basis for understanding the susceptibility and recovery of phrenic nerves in response to PFA and a need for appropriate caution in moving beyond animal models.
- Open Access
- 1 September 2020
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 13 (9) , e008337
Reduction in Pulmonary Vein Stenosis and Collateral Damage With Pulsed Field Ablation Compared With Radiofrequency Ablation in a Canine Model
Background: Pulmonary vein (PV) stenosis is a highly morbid condition that can result after catheter ablation for PV isolation. We hypothesized that pulsed field ablation (PFA) would reduce PV stenosis risk and collateral injury compared with irrigated radiofrequency ablation (IRF). Methods: IRF and PFA deliveries were randomized in 8 dogs with 2 superior PVs ablated using one technology and 2 inferior PVs ablated using the other technology. IRF energy (25–30 W) or PFA was delivered (16 pulse trains) at each PV in a proximal and in a distal site. Contrast computed tomography scans were collected at 0, 2, 4, 8, and 12-week (termination) time points to monitor PV cross-sectional area at each PV ablation site. Results: Maximum average change in normalized cross-sectional area at 4-weeks was −46.1±45.1% post-IRF compared with −5.5±20.5% for PFA ( P ≤0.001). PFA-treated targets showed significantly fewer vessel restrictions compared with IRF ( P ≤0.023). Necropsy showed expansive PFA lesions without stenosis in the proximal PV sites, compared with more confined and often incomplete lesions after IRF. At the distal PV sites, only IRF ablations were grossly identified based on focal fibrosis. Mild chronic parenchymal hemorrhage was noted in 3 left superior PV lobes after IRF. Damage to vagus nerves as well as evidence of esophagus dilation occurred at sites associated with IRF. In contrast, no lung, vagal nerve, or esophageal injury was observed at PFA sites. Conclusions: PFA significantly reduced risk of PV stenosis compared with IRF postprocedure in a canine model. IRF also caused vagus nerve, esophageal, and lung injury while PFA did not.
- 1 September 2020
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 13 (9) , e008337
Open AccessReduction in Pulmonary Vein Stenosis and Collateral Damage With Pulsed Field Ablation Compared With Radiofrequency Ablation in a Canine Model
Background: Pulmonary vein (PV) stenosis is a highly morbid condition that can result after catheter ablation for PV isolation. We hypothesized that pulsed field ablation (PFA) would reduce PV stenosis risk and collateral injury compared with irrigated radiofrequency ablation (IRF). Methods: IRF and PFA deliveries were randomized in 8 dogs with 2 superior PVs ablated using one technology and 2 inferior PVs ablated using the other technology. IRF energy (25–30 W) or PFA was delivered (16 pulse trains) at each PV in a proximal and in a distal site. Contrast computed tomography scans were collected at 0, 2, 4, 8, and 12-week (termination) time points to monitor PV cross-sectional area at each PV ablation site. Results: Maximum average change in normalized cross-sectional area at 4-weeks was −46.1±45.1% post-IRF compared with −5.5±20.5% for PFA ( P ≤0.001). PFA-treated targets showed significantly fewer vessel restrictions compared with IRF ( P ≤0.023). Necropsy showed expansive PFA lesions without stenosis in the proximal PV sites, compared with more confined and often incomplete lesions after IRF. At the distal PV sites, only IRF ablations were grossly identified based on focal fibrosis. Mild chronic parenchymal hemorrhage was noted in 3 left superior PV lobes after IRF. Damage to vagus nerves as well as evidence of esophagus dilation occurred at sites associated with IRF. In contrast, no lung, vagal nerve, or esophageal injury was observed at PFA sites. Conclusions: PFA significantly reduced risk of PV stenosis compared with IRF postprocedure in a canine model. IRF also caused vagus nerve, esophageal, and lung injury while PFA did not.
- Open Access
- 23 December 2015
- Published by SAGE Publications in Therapeutic Advances in Cardiovascular Disease
- Vol. 10 (4) , 185-191
Echocardiographic assessment of aortic valve annular and left ventricular outflow tract diameter in conscious and anesthetized adult sheep prior to prosthetic aortic valve implantation
Prosthetic heart valve implantation is commonly performed in patients that have valvular heart disease. Prior to clinical evaluation of newly developed prostheses, preclinical animal studies are performed for the assessment of both acute and chronic valvular function. Commonly, one size of valve is used in these preclinical studies, which can present difficulties with the implantation procedure and assessing valve function. Due to these potential problems, we developed a preoperative screening assessment in potential ovine candidates for prosthetic aortic valve implantation. By determining if there is a correlation between conscious and anesthetized echocardiographic examinations, an improvement in surgical confidence can predict that the animal is deemed a suitable candidate for a particular size of prosthetic valve for implantation prior to subjecting the animal to anesthesia and surgery. A total of 53 crossbred sheep (Ovis aries), male and female, 10–37 months of age, weighing between 41 and 77 kg, underwent conscious echocardiography and a subset of 29 of these animals underwent echocardiographic assessment under anesthesia for a preoperative valve size comparison in these animals prior to surgical prosthetic aortic valve implantation. Using 2D echocardiographic assessment, left ventricular outflow tract (LVOT) dimensions were assessed. The mean paired difference between anesthetized and conscious LVOT diameter measurement was −0.87 mm (p = 0.0066, standard deviation 1.598, 95% confidence interval, −0.4796, −0.26378, n = 29). This pilot study evaluation revealed that conscious echocardiographic assessment can play a role preoperatively in selecting potential candidates for surgical prosthetic aortic valve implantation, thereby minimizing the potential in prosthetic-native annular mismatching, which can contribute to altered LVOT function.
- 23 December 2015
- Published by SAGE Publications in Therapeutic Advances in Cardiovascular Disease
- Vol. 10 (4) , 185-191
Open AccessEchocardiographic assessment of aortic valve annular and left ventricular outflow tract diameter in conscious and anesthetized adult sheep prior to prosthetic aortic valve implantation
Prosthetic heart valve implantation is commonly performed in patients that have valvular heart disease. Prior to clinical evaluation of newly developed prostheses, preclinical animal studies are performed for the assessment of both acute and chronic valvular function. Commonly, one size of valve is used in these preclinical studies, which can present difficulties with the implantation procedure and assessing valve function. Due to these potential problems, we developed a preoperative screening assessment in potential ovine candidates for prosthetic aortic valve implantation. By determining if there is a correlation between conscious and anesthetized echocardiographic examinations, an improvement in surgical confidence can predict that the animal is deemed a suitable candidate for a particular size of prosthetic valve for implantation prior to subjecting the animal to anesthesia and surgery. A total of 53 crossbred sheep (Ovis aries), male and female, 10–37 months of age, weighing between 41 and 77 kg, underwent conscious echocardiography and a subset of 29 of these animals underwent echocardiographic assessment under anesthesia for a preoperative valve size comparison in these animals prior to surgical prosthetic aortic valve implantation. Using 2D echocardiographic assessment, left ventricular outflow tract (LVOT) dimensions were assessed. The mean paired difference between anesthetized and conscious LVOT diameter measurement was −0.87 mm (p = 0.0066, standard deviation 1.598, 95% confidence interval, −0.4796, −0.26378, n = 29). This pilot study evaluation revealed that conscious echocardiographic assessment can play a role preoperatively in selecting potential candidates for surgical prosthetic aortic valve implantation, thereby minimizing the potential in prosthetic-native annular mismatching, which can contribute to altered LVOT function.
- 24 June 2014
- Published by Wiley in Veterinary Surgery
- Vol. 43 (7) , 895-896
Anomalous Right Coronary Arterial-Aortic Fistula in an Adult Sheep
- 24 June 2014
- Published by Wiley in Veterinary Surgery
- Vol. 43 (7) , 895-896
Anomalous Right Coronary Arterial-Aortic Fistula in an Adult Sheep
- 1 July 2010
- Vol. 49 (4) , 472-4
Surgical approaches to vascular access for large-caliber devices in preclinical research models.
Percutaneous vascular access options in preclinical models are often smaller than the relevant structures in humans or undersized for early-prototype research devices. Here we describe the surgical approaches and results for surgical vascular access sites in preclinical swine and sheep models. Fourteen adult miniature swine underwent successful 18-French vascular access by means of thoracotomy to the brachiocephalic artery. In addition, 11 swine and 10 sheep underwent successful 22-French vascular access by means of retroperitoneal laparotomy to the abdominal aorta. The relevancy of approach angles and vessel tortuosity should be considered when selecting appropriate preclinical models and techniques. The techniques described are effective for delivery of large-caliber devices in preclinical testing.
- 1 July 2010
- Vol. 49 (4) , 472-4
Surgical approaches to vascular access for large-caliber devices in preclinical research models.
Percutaneous vascular access options in preclinical models are often smaller than the relevant structures in humans or undersized for early-prototype research devices. Here we describe the surgical approaches and results for surgical vascular access sites in preclinical swine and sheep models. Fourteen adult miniature swine underwent successful 18-French vascular access by means of thoracotomy to the brachiocephalic artery. In addition, 11 swine and 10 sheep underwent successful 22-French vascular access by means of retroperitoneal laparotomy to the abdominal aorta. The relevancy of approach angles and vessel tortuosity should be considered when selecting appropriate preclinical models and techniques. The techniques described are effective for delivery of large-caliber devices in preclinical testing.
- 1 January 2008
- Vol. 17 (1) , 110
In-vivo motion of mitral valve annuloplasty devices.
The long-term outcomes of mitral valve repairs are enhanced with an annuloplasty device. Although, in general, semirigid and rigid annuloplasty devices remodel the shape of the mitral valve annulus, the effect of geometric alteration on annular motion has not been fully assessed. Hence, the study aim was to investigate the influence of semi-rigid annuloplasty devices on the motion of the mitral valve annulus in adult sheep. Sonomicrometric crystals were attached to semi-rigid annuloplasty devices (CG Future Band and CG Future COMPOSITE Ring), as well as to intra- and epicardiac sites for motion assessment in 13 sheep. Following implantation, hemodynamic and sonomicrometric measurements were collected under normal sinus rhythm and during dobutamine challenge conditions. Sonomicrometric measurements showed variations in the degree of device motion and timing of motion changes, depending on device size and type. Measurement of transverse device width demonstrated a pre-systolic decrease in width. For devices with the largest annular motion, the transverse device width increased during ventricular systole, with an out-of-phase increase in mitral annular septal-lateral distance during diastole. However, the geometric device septal-lateral distance showed minimal change across all devices, indicating maintenance of posterior remodeling geometry. Three-dimensional analyses revealed vertical elevation of the anterior annulus above the posterior annular plane during ventricular systole, consistent with anterior annular folding. The maximum calculated annular area occurred during early to mid-ventricular diastole, providing for maximal valve orifice area during opening of the mitral valve. The minimum annular area occurred near end-diastole to early systole, consistent with valve closing. The study results suggest that semi-rigid posterior annuloplasty devices with absent or flexible anterior mitral valve annular segments allow for a dynamic anterior annulus while maintaining aggressive posterior annular remodeling. Future studies should be undertaken to investigate the interaction between the anterior mitral valve annulus and the aortic root following annuloplasty device implantation.
- 1 January 2008
- Vol. 17 (1) , 110
In-vivo motion of mitral valve annuloplasty devices.
The long-term outcomes of mitral valve repairs are enhanced with an annuloplasty device. Although, in general, semirigid and rigid annuloplasty devices remodel the shape of the mitral valve annulus, the effect of geometric alteration on annular motion has not been fully assessed. Hence, the study aim was to investigate the influence of semi-rigid annuloplasty devices on the motion of the mitral valve annulus in adult sheep. Sonomicrometric crystals were attached to semi-rigid annuloplasty devices (CG Future Band and CG Future COMPOSITE Ring), as well as to intra- and epicardiac sites for motion assessment in 13 sheep. Following implantation, hemodynamic and sonomicrometric measurements were collected under normal sinus rhythm and during dobutamine challenge conditions. Sonomicrometric measurements showed variations in the degree of device motion and timing of motion changes, depending on device size and type. Measurement of transverse device width demonstrated a pre-systolic decrease in width. For devices with the largest annular motion, the transverse device width increased during ventricular systole, with an out-of-phase increase in mitral annular septal-lateral distance during diastole. However, the geometric device septal-lateral distance showed minimal change across all devices, indicating maintenance of posterior remodeling geometry. Three-dimensional analyses revealed vertical elevation of the anterior annulus above the posterior annular plane during ventricular systole, consistent with anterior annular folding. The maximum calculated annular area occurred during early to mid-ventricular diastole, providing for maximal valve orifice area during opening of the mitral valve. The minimum annular area occurred near end-diastole to early systole, consistent with valve closing. The study results suggest that semi-rigid posterior annuloplasty devices with absent or flexible anterior mitral valve annular segments allow for a dynamic anterior annulus while maintaining aggressive posterior annular remodeling. Future studies should be undertaken to investigate the interaction between the anterior mitral valve annulus and the aortic root following annuloplasty device implantation.
- 1 January 2007
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 20 (3) , 187-193
Right Ventricular Outflow Tract Reconstructive Model in Adult Sheep
Patients born with congenital right ventricular outflow tract lesions are faced with invasive procedures to establish hemodynamic and physiological stability. Commonly, multiple subsequent surgical procedures are required due to deterioration of a previous repair. These procedures carry additive risks of mortality and morbidity. Less aggressive procedures with accompanying lower risk is ideal. Success in percutaneously placing a transcatheter valve has previously been reported; however, continued safety and efficacy of any technique needs continual assessment. We developed a model for preclinical evaluation of a percutaneous placement of a pulmonic transcatheter valve in adult sheep, including preoperative, surgical, and postoperative techniques for long-term evaluation. Adult sheep were assessed and determined to be acceptable for study enrollment. Perioperative antibiotics and analgesics were given prior to a left thoracotomy. A Medtronic, Hancock 1 valve conduit was inserted for reconstruction of the right ventricular outflow tract. The Hancock 1 valve conduit alone represented the control group and the test animals comprised the addition of a Melody™ transcatheter pulmonary valve (TPV), within the Hancock 1 valve conduit. Fifteen adult sheep survived the surgical implant procedure with no perioperative mortality. There were four early postoperative deaths, three due to infection and one due to heart failure, secondary to intraoperative heart block. The remaining 11 animals remained healthy, gained weight, and survived to termination at 5 months. An initial definite-sized valve conduit was implanted, followed by inserting a single size TPV, which allowed a more accurate physiological assessment of any chosen valve. Our developed adult sheep model for percutaneous TPV implantation for right ventricular outflow tract lesions was successful for long-term assessment by utilizing our preoperative, surgical, and postoperative techniques.
- 1 January 2007
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 20 (3) , 187-193
Right Ventricular Outflow Tract Reconstructive Model in Adult Sheep
Patients born with congenital right ventricular outflow tract lesions are faced with invasive procedures to establish hemodynamic and physiological stability. Commonly, multiple subsequent surgical procedures are required due to deterioration of a previous repair. These procedures carry additive risks of mortality and morbidity. Less aggressive procedures with accompanying lower risk is ideal. Success in percutaneously placing a transcatheter valve has previously been reported; however, continued safety and efficacy of any technique needs continual assessment. We developed a model for preclinical evaluation of a percutaneous placement of a pulmonic transcatheter valve in adult sheep, including preoperative, surgical, and postoperative techniques for long-term evaluation. Adult sheep were assessed and determined to be acceptable for study enrollment. Perioperative antibiotics and analgesics were given prior to a left thoracotomy. A Medtronic, Hancock 1 valve conduit was inserted for reconstruction of the right ventricular outflow tract. The Hancock 1 valve conduit alone represented the control group and the test animals comprised the addition of a Melody™ transcatheter pulmonary valve (TPV), within the Hancock 1 valve conduit. Fifteen adult sheep survived the surgical implant procedure with no perioperative mortality. There were four early postoperative deaths, three due to infection and one due to heart failure, secondary to intraoperative heart block. The remaining 11 animals remained healthy, gained weight, and survived to termination at 5 months. An initial definite-sized valve conduit was implanted, followed by inserting a single size TPV, which allowed a more accurate physiological assessment of any chosen valve. Our developed adult sheep model for percutaneous TPV implantation for right ventricular outflow tract lesions was successful for long-term assessment by utilizing our preoperative, surgical, and postoperative techniques.